Reproducibility of measurements of the peripapillary retinal nerve fibre layer thickness. Optical coherence tomography versus retinal thickness analyzer

被引:3
作者
Krist, R
Hoffmann, EM
Schwenn, O
机构
[1] Univ Mainz, Augenklin, D-55131 Mainz, Germany
[2] Burger Hosp, Frankfurt, Germany
来源
OPHTHALMOLOGE | 2005年 / 102卷 / 12期
关键词
peripapillary retinal nerve fibre layer thickness; optical coherence tomography; retinal thickness analyzer; reproducibility;
D O I
10.1007/s00347-005-1229-z
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. The aim of this study was to compare the intra- and inter-examiner reproducibility of measurements obtained by optical coherence tomography (OCT) and retinal thickness analyzer (RTA). Patients and methods. During a period of 2 months, 22 eyes of 16 patients and 6 healthy subjects were included. Two examiners (EMH, RK) successively performed three measurements of the peripapillary retinal nerve fibre layer (RNFL) thickness with RTA and OCT. The reproducibility of three individual measurements of one examiner (intra-examiner) as well as the reproducibility of the measurements between both examiners (inter-examiner) was evaluated using the Friedman test and sign test. Results. The average thickness of the peripapillary RNFL was 154.4 mu m for the first investigator (EMH) and 155.1 mu m for the other investigator (RK) measured with RTA. The results obtained by OCT were 137.3 mu m (EMH) and 138.9 mu m (RK), respectively, generally indicating a threefold smaller range. Comparing the three measurements of one single examiner, no appreciable intra-observer dependency neither for RTA (EMH: p=0.19, RK: p=0.95) norfor OCT (EMH:p=0.51, RK:p=0.62) was observed. Inter-examiner analysis for RTA and OCT also revealed an acceptable reproducibility. Conclusions. Measurements of peripapillary RNFL thickness using RTA and OCT exhibited intra- and inter-observer agreement.
引用
收藏
页码:1175 / +
页数:5
相关论文
共 50 条
[1]   Reproduzierbarkeit der Messung der peripapillären NervenfaserschichtdickeOptische Kohärenztomographie versus Retinal Thickness AnalyzerReproducibility of measurements of the peripapillary retinal nerve fibre layer thicknessOptical coherence tomography versus retinal thickness analyzer [J].
R. Krist ;
E. M. Hoffmann ;
O. Schwenn .
Der Ophthalmologe, 2005, 102 :1175-1180
[2]   Retinal thickness measurements with optical coherence tomography and the scanning retinal thickness analyzer [J].
Konno, S ;
Akiba, J ;
Yoshida, A .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2001, 21 (01) :57-61
[3]   Reproducibility of Retinal Nerve Fiber Layer Thickness Measurements Using Spectral Domain Optical Coherence Tomography [J].
Wu, Huijuan ;
de Boer, Johannes F. ;
Chen, Teresa C. .
JOURNAL OF GLAUCOMA, 2011, 20 (08) :470-476
[4]   Repeatability and reproducibility of retinal nerve fibre layer thickness measurements with the iVue-100 optical coherence tomographer [J].
Rampersad, Nishanee ;
Hansraj, Rekha .
AFRICAN HEALTH SCIENCES, 2018, 18 (02) :304-312
[5]   Comparison of foveal thickness measured with the retinal thickness analyzer and optical coherence tomography [J].
Neubauer, AS ;
Priglinger, S ;
Ullrich, S ;
Bechmann, M ;
Thiel, MJ ;
Ulbig, MW ;
Kampik, A .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2001, 21 (06) :596-601
[6]   Peripapillary retinal nerve fiber layer thickness in normal Japanese eyes measured with optical coherence tomography [J].
Kanno, Makoto ;
Nagasawa, Michi ;
Suzuki, Michiro ;
Yamashita, Hidetoshi .
JAPANESE JOURNAL OF OPHTHALMOLOGY, 2010, 54 (01) :36-42
[7]   Retinal nerve fibre layer thickness measurements by optical coherence tomography in patients with sleep apnoea syndrome [J].
Sagiv, Oded ;
Fishelson-Arev, Tagil ;
Buckman, Gila ;
Mathalone, Nurit ;
Wolfson, Julia ;
Segev, Eitan ;
Peled, Ron ;
Lavi, Idit ;
Geyer, Orna .
CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 42 (02) :132-138
[8]   Reproducibility of Retinal Nerve Fiber Layer and Macular Ganglion Cell Layer Thickness Measurements by Optical Coherence Tomography in Myopic Eyes [J].
Park, Sang Min ;
Lee, Kwan Bok ;
Kim, Kyoung Nam ;
Hwang, Young Hoon .
JOURNAL OF GLAUCOMA, 2021, 30 (09) :834-838
[9]   Reproducibility of Retinal Nerve Fiber Layer and Macular Thickness Measurements Using Spectral Domain Optical Coherence Tomography [J].
Sood, Amit ;
Paliwal, Rahul Omprakash ;
Mishra, Rishu Yogesh .
GALICIAN MEDICAL JOURNAL, 2021, 28 (04)
[10]   The Paediatric Glaucoma Diagnostic Ability of Optical Coherence Tomography: A Comparison of Macular Segmentation and Peripapillary Retinal Nerve Fibre Layer Thickness [J].
Lever, Mael ;
Halfwassen, Christian ;
Unterlauft, Jan Darius ;
Bechrakis, Nikolaos E. ;
Manthey, Anke ;
Bohm, Michael R. R. .
BIOLOGY-BASEL, 2021, 10 (04)