Reproducibility of measurements of the peripapillary retinal nerve fibre layer thickness. Optical coherence tomography versus retinal thickness analyzer

被引:3
|
作者
Krist, R
Hoffmann, EM
Schwenn, O
机构
[1] Univ Mainz, Augenklin, D-55131 Mainz, Germany
[2] Burger Hosp, Frankfurt, Germany
来源
OPHTHALMOLOGE | 2005年 / 102卷 / 12期
关键词
peripapillary retinal nerve fibre layer thickness; optical coherence tomography; retinal thickness analyzer; reproducibility;
D O I
10.1007/s00347-005-1229-z
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. The aim of this study was to compare the intra- and inter-examiner reproducibility of measurements obtained by optical coherence tomography (OCT) and retinal thickness analyzer (RTA). Patients and methods. During a period of 2 months, 22 eyes of 16 patients and 6 healthy subjects were included. Two examiners (EMH, RK) successively performed three measurements of the peripapillary retinal nerve fibre layer (RNFL) thickness with RTA and OCT. The reproducibility of three individual measurements of one examiner (intra-examiner) as well as the reproducibility of the measurements between both examiners (inter-examiner) was evaluated using the Friedman test and sign test. Results. The average thickness of the peripapillary RNFL was 154.4 mu m for the first investigator (EMH) and 155.1 mu m for the other investigator (RK) measured with RTA. The results obtained by OCT were 137.3 mu m (EMH) and 138.9 mu m (RK), respectively, generally indicating a threefold smaller range. Comparing the three measurements of one single examiner, no appreciable intra-observer dependency neither for RTA (EMH: p=0.19, RK: p=0.95) norfor OCT (EMH:p=0.51, RK:p=0.62) was observed. Inter-examiner analysis for RTA and OCT also revealed an acceptable reproducibility. Conclusions. Measurements of peripapillary RNFL thickness using RTA and OCT exhibited intra- and inter-observer agreement.
引用
收藏
页码:1175 / +
页数:5
相关论文
共 50 条
  • [1] Reproduzierbarkeit der Messung der peripapillären NervenfaserschichtdickeOptische Kohärenztomographie versus Retinal Thickness AnalyzerReproducibility of measurements of the peripapillary retinal nerve fibre layer thicknessOptical coherence tomography versus retinal thickness analyzer
    R. Krist
    E. M. Hoffmann
    O. Schwenn
    Der Ophthalmologe, 2005, 102 : 1175 - 1180
  • [2] Retinal thickness measurements with optical coherence tomography and the scanning retinal thickness analyzer
    Konno, S
    Akiba, J
    Yoshida, A
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2001, 21 (01): : 57 - 61
  • [3] Reproducibility of Retinal Nerve Fiber Layer Thickness Measurements Using Spectral Domain Optical Coherence Tomography
    Wu, Huijuan
    de Boer, Johannes F.
    Chen, Teresa C.
    JOURNAL OF GLAUCOMA, 2011, 20 (08) : 470 - 476
  • [4] Repeatability and reproducibility of retinal nerve fibre layer thickness measurements with the iVue-100 optical coherence tomographer
    Rampersad, Nishanee
    Hansraj, Rekha
    AFRICAN HEALTH SCIENCES, 2018, 18 (02) : 304 - 312
  • [5] Comparison of foveal thickness measured with the retinal thickness analyzer and optical coherence tomography
    Neubauer, AS
    Priglinger, S
    Ullrich, S
    Bechmann, M
    Thiel, MJ
    Ulbig, MW
    Kampik, A
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2001, 21 (06): : 596 - 601
  • [6] Peripapillary retinal nerve fiber layer thickness in normal Japanese eyes measured with optical coherence tomography
    Kanno, Makoto
    Nagasawa, Michi
    Suzuki, Michiro
    Yamashita, Hidetoshi
    JAPANESE JOURNAL OF OPHTHALMOLOGY, 2010, 54 (01) : 36 - 42
  • [7] Retinal nerve fibre layer thickness measurements by optical coherence tomography in patients with sleep apnoea syndrome
    Sagiv, Oded
    Fishelson-Arev, Tagil
    Buckman, Gila
    Mathalone, Nurit
    Wolfson, Julia
    Segev, Eitan
    Peled, Ron
    Lavi, Idit
    Geyer, Orna
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 42 (02) : 132 - 138
  • [8] Reproducibility of Retinal Nerve Fiber Layer and Macular Ganglion Cell Layer Thickness Measurements by Optical Coherence Tomography in Myopic Eyes
    Park, Sang Min
    Lee, Kwan Bok
    Kim, Kyoung Nam
    Hwang, Young Hoon
    JOURNAL OF GLAUCOMA, 2021, 30 (09) : 834 - 838
  • [9] Reproducibility of Retinal Nerve Fiber Layer and Macular Thickness Measurements Using Spectral Domain Optical Coherence Tomography
    Sood, Amit
    Paliwal, Rahul Omprakash
    Mishra, Rishu Yogesh
    GALICIAN MEDICAL JOURNAL, 2021, 28 (04)
  • [10] Comparison of two retinal nerve fibre layer thickness measurement patterns of RTvue optical coherence tomography
    Li, Shuning
    Wang, Xiaozhen
    Wu, Gewei
    Fu, Jing
    Li, Songfeng
    Wan, Xiuhua
    Wang, Ningli
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 39 (03) : 222 - 229