Reproducibility of measurements of the peripapillary retinal nerve fibre layer thickness. Optical coherence tomography versus retinal thickness analyzer

被引:3
作者
Krist, R
Hoffmann, EM
Schwenn, O
机构
[1] Univ Mainz, Augenklin, D-55131 Mainz, Germany
[2] Burger Hosp, Frankfurt, Germany
来源
OPHTHALMOLOGE | 2005年 / 102卷 / 12期
关键词
peripapillary retinal nerve fibre layer thickness; optical coherence tomography; retinal thickness analyzer; reproducibility;
D O I
10.1007/s00347-005-1229-z
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. The aim of this study was to compare the intra- and inter-examiner reproducibility of measurements obtained by optical coherence tomography (OCT) and retinal thickness analyzer (RTA). Patients and methods. During a period of 2 months, 22 eyes of 16 patients and 6 healthy subjects were included. Two examiners (EMH, RK) successively performed three measurements of the peripapillary retinal nerve fibre layer (RNFL) thickness with RTA and OCT. The reproducibility of three individual measurements of one examiner (intra-examiner) as well as the reproducibility of the measurements between both examiners (inter-examiner) was evaluated using the Friedman test and sign test. Results. The average thickness of the peripapillary RNFL was 154.4 mu m for the first investigator (EMH) and 155.1 mu m for the other investigator (RK) measured with RTA. The results obtained by OCT were 137.3 mu m (EMH) and 138.9 mu m (RK), respectively, generally indicating a threefold smaller range. Comparing the three measurements of one single examiner, no appreciable intra-observer dependency neither for RTA (EMH: p=0.19, RK: p=0.95) norfor OCT (EMH:p=0.51, RK:p=0.62) was observed. Inter-examiner analysis for RTA and OCT also revealed an acceptable reproducibility. Conclusions. Measurements of peripapillary RNFL thickness using RTA and OCT exhibited intra- and inter-observer agreement.
引用
收藏
页码:1175 / +
页数:5
相关论文
共 18 条
[1]   Retinal thickness decreases with age: an OCT study [J].
Alamouti, B ;
Funk, J .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2003, 87 (07) :899-901
[2]  
DREHER AW, 1992, CLIN VISION SCI, V7, P481
[3]  
DREHER AW, 1992, P SOC PHOTO-OPT INS, V1746, P34, DOI 10.1117/12.138806
[4]   OPTICAL COHERENCE TOMOGRAPHY OF THE HUMAN RETINA [J].
HEE, MR ;
IZATT, JA ;
SWANSON, EA ;
HUANG, D ;
SCHUMAN, JS ;
LIN, CP ;
PULIAFITO, CA ;
FUJIMOTO, JG .
ARCHIVES OF OPHTHALMOLOGY, 1995, 113 (03) :325-332
[5]   OPTICAL COHERENCE TOMOGRAPHY [J].
HUANG, D ;
SWANSON, EA ;
LIN, CP ;
SCHUMAN, JS ;
STINSON, WG ;
CHANG, W ;
HEE, MR ;
FLOTTE, T ;
GREGORY, K ;
PULIAFITO, CA ;
FUJIMOTO, JG .
SCIENCE, 1991, 254 (5035) :1178-1181
[6]   The Humphrey optical coherence tomography scanner: quantitative analysis and reproducibility study of the normal human retinal nerve fibre layer [J].
Jones, AL ;
Sheen, NJL ;
North, RV ;
Morgan, JE .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2001, 85 (06) :673-677
[7]  
Klemm M, 2002, OPHTHALMOLOGE, V99, P345, DOI 10.1007/s00347-001-0556-y
[8]   Retinal thickness measurements with optical coherence tomography and the scanning retinal thickness analyzer [J].
Konno, S ;
Akiba, J ;
Yoshida, A .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2001, 21 (01) :57-61
[9]   Comparison of foveal thickness measured with the retinal thickness analyzer and optical coherence tomography [J].
Neubauer, AS ;
Priglinger, S ;
Ullrich, S ;
Bechmann, M ;
Thiel, MJ ;
Ulbig, MW ;
Kampik, A .
RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2001, 21 (06) :596-601
[10]   Comparison between retinal thickness analyzer and optical coherence tomography for assessment of foveal thickness in eyes with macular disease [J].
Polito, A ;
Shah, SM ;
Haller, JA ;
Zimmer-Galler, I ;
Zeimer, R ;
Campochiaro, PA ;
Vitale, S .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2002, 134 (02) :240-251