Effect of Glucose Concentration on Electrochemical Corrosion Behavior of Pure Titanium TA2 in Hanks' Simulated Body Fluid

被引:15
作者
Liu, Shuyue [1 ]
Wang, Bing [2 ,3 ]
Zhang, Peirong [2 ]
机构
[1] Shandong Normal Univ, High Sch, Jinan 250014, Peoples R China
[2] Shandong Univ, Sch Mech Engn, Key Lab High Efficiency & Clean Mech Mfg, MOE, Jinan 250061, Peoples R China
[3] Michigan State Univ, Dept Mech Engn, Lansing, MI 48910 USA
来源
MATERIALS | 2016年 / 9卷 / 11期
基金
中国国家自然科学基金;
关键词
glucose concentration; corrosion; pure titanium; simulated body fluid; implant; ALLOY; ENVIRONMENT; IMPLANTS;
D O I
10.3390/ma9110874
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Titanium and its alloys have been widely used as implant materials due to their excellent mechanical property and biocompatibility. In the present study, the effect of glucose concentration on corrosion behavior of pure titanium TA2 in Hanks' simulated body fluid is investigated by the electrochemical impedance spectrum (EIS) and potentiodynamic polarization methods. The range of glucose concentrations investigated in this research includes 5 mmol/L (limosis for healthy people), 7 mmol/L (after diet for healthy people), 10 mmol/L (limosis for hyperglycemia patient), and 12 mmol/L (after diet for hyperglycemia patient), as well as, 15 mmol/L and 20 mmol/L, which represent different body fluid environments. The results indicate that the pure titanium TA2 demonstrates the best corrosion resistance when the glucose concentration is less than 10 mmol/L, which shows that the pure titanium TA2 as implant material can play an effective role in the body fluids with normal and slight high glucose concentrations. Comparatively, the corrosion for the pure titanium implant is more probable when the glucose concentration is over 10 mmol/L due to the premature penetration through passive film on the material surface. Corrosion defects of pitting and crevice exist on the corroded surface, and the depth of corrosion is limited to three microns with a low corrosion rate. The oxidation film on the surface of pure titanium TA2 has a protective effect on the corrosion behavior of the implant inner material. The corrosion behavior of pure titanium TA2 will happen easily once the passive film has been penetrated through. The corrosion rate for TA2 implant will accelerate quickly and a pure titanium implant cannot be used.
引用
收藏
页数:11
相关论文
共 20 条
  • [1] Bhola R., 2011, ARTIF ORGANS, V25, P34
  • [2] Bovo R, 2008, ACTA OTORHINOLARYNGO, V28, P252
  • [3] Effect of replacement of V by Nb and Fe on the electrochemical and corrosion behavior of Ti-6Al-4V in simulated physiological environment
    Choubey, A
    Balasubramaniam, R
    Basu, B
    [J]. JOURNAL OF ALLOYS AND COMPOUNDS, 2004, 381 (1-2) : 288 - 294
  • [4] Wear and corrosion behaviour of Ti-13Nb-13Zr and Ti-6Al-4V alloys in simulated physiological solution
    Cvijovic-Alagic, I.
    Cvijovic, Z.
    Mitrovic, S.
    Panic, V.
    Rakin, M.
    [J]. CORROSION SCIENCE, 2011, 53 (02) : 796 - 808
  • [5] Titanium alloys and their machinability - A review
    Ezugwu, EO
    Wang, ZM
    [J]. JOURNAL OF MATERIALS PROCESSING TECHNOLOGY, 1997, 68 (03) : 262 - 274
  • [6] Electrochemically induced anatase inhibits bacterial colonization on Titanium Grade 2 and Ti6Al4V alloy for dental and orthopedic devices
    Giordano, Carmen
    Saino, Enrica
    Rimondini, Lia
    Pedeferri, Maria Pia
    Visai, Livia
    Cigada, Alberto
    Chiesa, Roberto
    [J]. COLLOIDS AND SURFACES B-BIOINTERFACES, 2011, 88 (02) : 648 - 655
  • [7] Influence of sulfide concentration on the corrosion behavior of titanium in a simulated oral environment
    Harada, Rino
    Takemoto, Shinji
    Kinoshita, Hideaki
    Yoshinari, Masao
    Kawada, Eiji
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2016, 62 : 268 - 273
  • [8] Titanium dental implants surface-immobilized with gold nanoparticles as osteoinductive agents for rapid osseointegration
    Heo, Dong Nyoung
    Ko, Wan-Kyu
    Lee, Hak Rae
    Lee, Sang Jin
    Lee, Donghyun
    Um, Soong Ho
    Lee, Jung Haeng
    Woo, Yi-Hyung
    Zhang, Lijie Grace
    Lee, Deok-Won
    Kwon, Il Keun
    [J]. JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2016, 469 : 129 - 137
  • [9] Stability Testing of a Wide Bone-Anchored Device after Surgery without Skin Thinning
    Hultcrantz, Malou
    [J]. BIOMED RESEARCH INTERNATIONAL, 2015, 2015
  • [10] COMPARISON OF THE CORROSION BEHAVIOR AND SURFACE MORPHOLOGY OF NiTi ALLOY AND STAINLESS STEELS IN SODIUM CHLORIDE SOLUTION
    Kozuh, S.
    Vrsalovic, L.
    Gojic, M.
    Gudic, S.
    Kosec, B.
    [J]. JOURNAL OF MINING AND METALLURGY SECTION B-METALLURGY, 2016, 52 (01) : 53 - 61