Monitoring unfractionated heparin with APTT: A French collaborative study comparing sensitivity to heparin of 15 APTT reagents

被引:21
作者
Gouin-Thibaut, Isabelle [6 ,7 ]
Martin-Toutain, Isabelle [5 ]
Peynaud-Debayle, Edith [4 ]
Marion, Sylvie [3 ]
Napol, Patricia [2 ]
Alhenc-Gelas, Martine [1 ]
机构
[1] Hop Europeen Georges Pompidou, AP HP, Serv Hematol Biol, F-75015 Paris, France
[2] AGEPS, AP HP, Paris, France
[3] Hop P Brousse, AP HP, Villejuif, France
[4] Hop L Mourier, AP HP, Serv Hematol Biol, Colombes, France
[5] Hop La Pitie Salpetriere, AP HP, Serv Hematol Biol, Paris, France
[6] Hop C Foix, AP HP, Serv Hematol Biol, Paris, France
[7] Hop Hotel Dieu, Paris, France
关键词
THERAPY;
D O I
10.1016/j.thromres.2011.11.016
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:666 / 667
页数:2
相关论文
共 10 条
[1]   Guidelines on the use and monitoring of heparin [J].
Baglin, T ;
Barrowcliffe, TW ;
Cohen, A ;
Greaves, M .
BRITISH JOURNAL OF HAEMATOLOGY, 2006, 133 (01) :19-34
[2]   PROSPECTIVE STUDY OF VALUE OF MONITORING HEPARIN TREATMENT WITH ACTIVATED PARTIAL THROMBOPLASTIN TIME [J].
BASU, D ;
CADE, J ;
GALLUS, A ;
HIRSH, J .
NEW ENGLAND JOURNAL OF MEDICINE, 1972, 287 (07) :324-+
[3]   Interlaboratory agreement in the monitoring of unfractionated heparin using the anti-factor Xa-correlated activated partial thromboplastin time [J].
Cuker, A. ;
Ptashkin, B. ;
Konkle, B. A. ;
Pipe, S. W. ;
Whinna, H. C. ;
Zheng, X. L. ;
Cines, D. B. ;
Pollak, E. S. .
JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2009, 7 (01) :80-86
[4]   Interlaboratory variation in heparin monitoring: Lessons from the Quality Management Program of Ontario coagulation surveys [J].
Cuker, Adam ;
Raby, Anne ;
Moffat, Karen A. ;
Flynn, Greg ;
Crowther, Mark A. .
THROMBOSIS AND HAEMOSTASIS, 2010, 104 (04) :837-844
[5]   Parenteral anticoagulants [J].
Hirsh, Jack ;
Bauer, Kenneth A. ;
Donati, Maria B. ;
Gould, Michael ;
Samama, Meyer M. ;
Weitz, Jeffrey I. .
CHEST, 2008, 133 (06) :141S-159S
[6]  
Kitchen S, 1996, THROMB HAEMOSTASIS, V75, P734
[7]   Wide variability in the sensitivity of APTT reagents for monitoring of heparin dosage [J].
Kitchen, S ;
Jennings, I ;
Woods, TAL ;
Preston, FE .
JOURNAL OF CLINICAL PATHOLOGY, 1996, 49 (01) :10-14
[8]   Problems in laboratory monitoring of heparin dosage [J].
Kitchen, S .
BRITISH JOURNAL OF HAEMATOLOGY, 2000, 111 (02) :397-406
[9]   Evaluation of the activated partial thromboplastin time (APTT) sensitivity to heparin using five commercial reagents: Implications for therapeutic monitoring [J].
Manzato, F ;
Mengoni, A ;
Grilenzoni, A ;
Lippi, G .
CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 1998, 36 (12) :975-980
[10]  
Olson JD, 1998, ARCH PATHOL LAB MED, V122, P782