Analysis of penalized likelihood reconstruction for PET kinetic quantification

被引:0
作者
Wang, Guobao [1 ]
Qi, Jinyi [1 ]
机构
[1] Univ Calif Davis, Dept Biomed Engn, Davis, CA 95616 USA
来源
2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11 | 2007年
关键词
image reconstruction; penalized maximum likelihood; tracer kinetic modeling; noise analysis;
D O I
10.1109/NSSMIC.2007.4436838
中图分类号
O59 [应用物理学];
学科分类号
摘要
Quantification of tracer kinetics using dynamic positron emission tomography provides important information for understanding the physiological and biochemical processes in humans and animals. The common procedure is to reconstruct a sequence of dynamic images first, and then apply kinetic analysis to the time activity curve of a region of interest derived from the reconstructed images. Obviously, the choice of image reconstruction method and its parameters affect the accuracy of the time activity curve and hence the estimated kinetic parameters. This paper analyzes the effects of penalized likelihood image reconstruction on tracer kinetic parameter estimation. Approximate theoretical expressions are derived to study the bias, variance, and ensemble mean squares error of the estimated kinetic parameters. Computer simulations show that these formulae predict correctly the changes of these statistics as functions of the regularization parameter. It is found that the choice of the regularization parameter has a significant impact on kinetic parameter estimation, indicating proper selection of image reconstruction parameters is important for dynamic PET. A practical method has also been developed to use the theoretical formulae to guide the selection of the regularization parameter in dynamic PET image reconstruction.
引用
收藏
页码:3283 / 3293
页数:11
相关论文
共 37 条
[31]  
RAYLMAN RR, 1993, J NUCL MED, V34, P440
[32]   An investigation into the effect of input function shape and image acquisition interval on estimates of washin for dynamic cardiac SPECT [J].
Ross, SG ;
Welch, A ;
Gullberg, GT ;
Huesman, RH .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (11) :2193-2213
[33]   Noise characterization of block-iterative reconstruction algorithms: I. Theory [J].
Soares, EJ ;
Byrne, CL ;
Glick, SJ .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (04) :261-270
[34]   Noise analysis of MAP-EM algorithms for emission tomography [J].
Wang, WL ;
Gindi, G .
PHYSICS IN MEDICINE AND BIOLOGY, 1997, 42 (11) :2215-2232
[35]   Effect of reconstruction and filtering on kinetic parameter estimation bias and reliability for dynamic SPECT: A simulation study [J].
Wen, LF ;
Eberl, S ;
Wong, KP ;
Feng, DG ;
Bai, J .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (01) :69-78
[36]   Analysis of observer performance in known-location tasks for tomographic image reconstruction [J].
Yendiki, A ;
Fessler, JA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2006, 25 (01) :28-41
[37]  
YU DC, 1993, J NUCL MED, V34, P679