Repeatability of Corneal Deformation Response Parameters by Dynamic Ultra High-speed Scheimpflug Imaging in Normal and Keratoconus Eyes

被引:4
作者
Henriquez, Maria A. [1 ]
Gomez, Isabel [1 ]
Camino-Quezada, Maythe [1 ]
Izquierdo, Luis, Jr. [1 ]
Chauca, Jose [1 ,2 ]
Binder, Perry S. [3 ]
机构
[1] Oftalmosalud Inst Eyes, Res Dept, Lima, Peru
[2] Univ Pemana Cayetano Heredia, Dept Stat Demog Humanities & Social Sci, Lima, Peru
[3] Univ Calif Irvine, Gavin Herbert Eye Inst, Irvine, CA USA
来源
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE | 2022年 / 48卷 / 01期
关键词
Keratoconus; Corneal dynamic response; Scheimpflug imaging; Repeatability; corvis; corneal biomechanics; CROSS-LINKING; BIOMECHANICAL PROPERTIES; TOMOGRAPHY; REPRODUCIBILITY;
D O I
10.1097/ICL.0000000000000845
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To assess the repeatability of corneal dynamic response (CDR) parameters in normal and keratoconus (KC) eyes using ultra high-speed Scheimpflug imaging. Methods: Prospective, comparative, observational study, including eyes of 112 patients that underwent high-speed Scheimpflug imaging analysis (Corvis ST, OCULUS). Twenty-one CDR parameters were evaluated to asses repeatability using: coefficient of repeatability (CR), coefficient of variation, intraclass correlation coefficient (ICC) and within-subject SD. Three consecutive measurements by the same operator were performed for each eye. Results: There were no significant differences between the three consecutive measurements for all parameters in both normal and KC eyes. 71.42% (15 of the 21 parameters evaluated) and 85.71% (18 of the 21 parameters) were highly repeatable in the normal and KC group, respectively. The tomographic biomechanical index (TBI), corneal biomechanical index (CBI), and stiffness parameter (SPA1) showed an ICC of 0.978, 0.954, and 0.958 in normal and 0.982, 0.892, and 0.978 in KC eyes, respectively. The CR in normal eyes for TBI, CBI, and SPA1 were 0.169, 0.242, and 14.12, respectively, and for KC eyes 0.06, 0.23, and 13.64, respectively. Conclusions: Most of the corneal dynamic response parameters were highly repeatable in normal and KC eyes.
引用
收藏
页码:14 / 19
页数:6
相关论文
共 22 条
[1]  
Ambrosio Renato Jr, 2017, Open Ophthalmol J, V11, P176, DOI 10.2174/1874364101711010176
[2]   Integration of Scheimpflug-Based Corneal Tomography and Biomechanical Assessments for Enhancing Ectasia Detection [J].
Ambrosio, Renato, Jr. ;
Lopes, Bernardo T. ;
Faria-Correia, Fernando ;
Salomao, Marcella Q. ;
Buhren, Jens ;
Roberts, Cynthia J. ;
Elsheikh, Ahmed ;
Vinciguerra, Riccardo ;
Vinciguerra, Paolo .
JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (07) :434-+
[3]   Novel Pachymetric Parameters Based on Corneal Tomography for Diagnosing Keratoconus [J].
Ambrosio, Renato, Jr. ;
Caiado, Ana Laura C. ;
Guerra, Frederico P. ;
Louzada, Ricardo ;
Roy, Abhijit Sinha ;
Luz, Allan ;
Dupps, William J. ;
Belin, Michael W. .
JOURNAL OF REFRACTIVE SURGERY, 2011, 27 (10) :753-758
[4]   The Role of Corneal Biomechanics in the Assessment of Ectasia Susceptibility Before Laser Vision Correction [J].
Baptista, Pedro Manuel ;
Marta, Ana Ambrosio ;
Marques, Joao Heitor ;
Abreu, Ana Carolina ;
Monteiro, Silvia ;
Meneres, Pedro ;
Pinto, Maria do Ceu .
CLINICAL OPHTHALMOLOGY, 2021, 15 :745-758
[5]   Reliability, repeatability and reproducibility: analysis of measurement errors in continuous variables [J].
Bartlett, J. W. ;
Frost, C. .
ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2008, 31 (04) :466-475
[6]   Reproductivity and repeatability of central corneal thickness measurement in keratoconus using the rotating scheimpflug camera and ultrasound pachymetry [J].
De Sanctis, Ugo ;
Missolungi, Alessandro ;
Mutani, Bernardo ;
Richiardi, Lorenzo ;
Grignolo, Federico M. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2007, 144 (05) :712-718
[7]   Corneal Biomechanics After Accelerated Cross-linking: Comparison Between 18 and 9 mW/cm2 Protocols [J].
Hashemi, Hassan ;
Asgari, Soheila ;
Mehravaran, Shiva ;
Miraftab, Mohammad ;
Ghaffari, Reza ;
Fotouhi, Akbar .
JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (08) :558-U157
[8]   Repeatability and reproducibility of corneal deformation response parameters of dynamic ultra-high-speed Scheimpflug imaging in keratoconus [J].
Herber, Robert ;
Vinciguerra, Riccardo ;
Lopes, Bernardo ;
Raiskup, Frederik ;
Pillunat, Lutz E. ;
Vinciguerra, Paolo ;
Ambrosio, Renato, Jr. .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (01) :86-94
[9]   Corneal biomechanical outcome of collagen cross-linking in keratoconic patients evaluated by Corvis ST [J].
Jabbarvand, Mahmoud ;
Moravvej, Zahra ;
Shahraki, Kianoush ;
Hashemian, Hessam ;
Ghasemi, Hamed ;
Berijani, Sahar ;
Amiri, Zahra ;
Jamali, Alireza .
EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2021, 31 (04) :1577-1583
[10]   Corneal biomechanics - a review [J].
Kling, Sabine ;
Hafezi, Farhad .
OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2017, 37 (03) :240-252