Quantification of coronary artery stenosis with 16-slice MSCT in patients before CABG surgery: Comparison to standard invasive coronary angiography

被引:12
作者
Probst, C
Kovacs, A
Schmitz, C
Schiller, W
Schild, H
Welz, A
机构
[1] Univ Bonn, Dept Cardiac Surg, D-53127 Bonn, Germany
[2] Univ Bonn, Dept Radiol, D-53127 Bonn, Germany
关键词
D O I
10.1532/HSF98.20041144
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Invasive, selective coronary angiography is the gold standard for evaluation of coronary artery disease ( CAD) and degree of stenosis. The purpose of this study was to compare 3-dimensional (3D) reconstructed 16-slice multislice computed tomographic (MSCT) angiography and selective coronary angiography in patients before elective coronary artery bypass graft (CABG) procedure. Methods: Sixteen-slice MSCT scans (Philips Mx8000 IDT) were performed in 50 patients ( 42 male/8 female; mean age, 64.44 +/- 8.66 years) scheduled for elective CABG procedure. Scans were retrospectively electrocardiogram-gated 3D reconstructed. The images of the coronary arteries were evaluated for stenosis by 2 independent radiologists. The results were compared with the coronary angiography findings using the American Heart Association segmental classification for coronary arteries. Results: Four patients (8%) were excluded for technical reasons. Thirty-eight patients (82.6%) had 3-vessel disease, 4 (8.7%) had 2-vessel disease, and 4 ( 8.7%) had an isolated left anterior descending artery stenosis. In the proximal segments all stenoses > 50% (56/56) were detected by MSCT; medial segment sensitivity was 97% (73/75), specificity 90.3%; distal segment sensitivity was 90.7% (59/65), specificity 77%. Conclusion: Accurate quanti. cation of coronary stenosis greater than 50% in the proximal and medial segments is possible with high sensitivity and specificity using the new generation of 16-slice MSCTs. There is still a tendency to overestimate stenosis in the distal segments. MSCT seems to be an excellent diagnostic tool for screening patients with possible CAD.
引用
收藏
页码:E42 / E46
页数:5
相关论文
共 50 条
[1]   The accuracy of 4-slice computer tomography and 16-slice computer tomography in the detection and quantification of significant (50%) coronary artery stenosis in comparison with coronary angiography [J].
Pasowicz, M ;
Klimeczek, P ;
Zajdel, W ;
Bany, R ;
Zmudka, K .
EUROPEAN HEART JOURNAL, 2004, 25 :117-117
[2]   Validation of non-invasive coronary angiography by 16-slice multidetector spiral computed tomography in comparison to invasive coronary angiography [J].
Kaiser, C ;
Pater, S ;
Bremerich, J ;
Bongartz, G ;
Steinbrich, W ;
Pfisterer, M ;
Buser, P .
EUROPEAN HEART JOURNAL, 2003, 24 :725-725
[3]   Validation of non-invasive coronary angiography by 16-slice multidetector spiral computed tomography in comparison to invasive coronary angiography [J].
Kaiser, C ;
Pater, S ;
Bremerich, J ;
Bongartz, G ;
Steinbrich, W ;
Pfisterer, M ;
Buser, P .
CIRCULATION, 2003, 108 (17) :672-672
[4]   Noninvasive Detection of Coronary Artery Stenosis Using 16-slice Spiral CT: a Comparison with Selective X-ray Coronary Angiography [J].
史河水 ;
韩萍 ;
孔祥泉 ;
冯敢生 ;
Martin HK Hoffmann .
华中科技大学学报(医学英德文版), 2006, (03) :338-340
[5]   Noninvasive detection of coronary artery stenosis using 16-slice spiral CT: A comparison with selective X-ray coronary angiography [J].
Shi Heshui ;
Han Ping ;
Kong Xiangquan ;
Feng Gangsheng ;
Martin HK Hoffmann .
Journal of Huazhong University of Science and Technology [Medical Sciences], 2006, 26 (3) :338-340
[6]   Diagnostic accuracy of 16-slice CT coronary angiography in the evaluation of coronary artery disease [J].
Soon, K. H. ;
Chaitowitz, I. ;
Cox, N. ;
MacGregor, L. ;
Eccleston, D. ;
Bell, K. W. ;
Kelly, A-M ;
Lim, Y. L. .
AUSTRALASIAN RADIOLOGY, 2007, 51 (04) :365-369
[7]   CABG patients: better coronary CT before invasive coronary angiography? [J].
Dahm, Johannes B. .
AKTUELLE KARDIOLOGIE, 2024, 13 (01)
[8]   Coronary stenosis detection by 16-slice computed tomography in heart transplanted patients: Comparison with conventional coronary angiography and impact on clinical management [J].
Romeo, G ;
Houyel, L ;
Paul, JF ;
Brenot, P ;
Riou, JY ;
Angel, CY .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (03) :283A-283A
[9]   Coronary Angiography by 16-Slice Computed Tomography Prior to Valvular Surgery [J].
Rodriguez-Palomares, Jose F. ;
Cuellar, Hug ;
Marti, Gerard ;
Garcia, Bruno ;
Teresa Gonzalez-Alujas, M. ;
Mahia, Patricia ;
Evangelista, Arturo ;
Tornos, Pilar ;
Garcia-Dorado, David .
REVISTA ESPANOLA DE CARDIOLOGIA, 2011, 64 (04) :269-276
[10]   Coronary stenosis detection by 16-slice computed tomography in heart transplant patients: Comparison with conventional coronary angiography and impact on clinical management [J].
Romeo, G. ;
Houyel, L. ;
Paul, J. F. ;
Brenot, P. ;
Riou, J. Y. ;
Angel, C. Y. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2005, 24 (02) :S114-S114