Quantification of coronary artery stenosis with 16-slice MSCT in patients before CABG surgery: Comparison to standard invasive coronary angiography

被引:12
|
作者
Probst, C
Kovacs, A
Schmitz, C
Schiller, W
Schild, H
Welz, A
机构
[1] Univ Bonn, Dept Cardiac Surg, D-53127 Bonn, Germany
[2] Univ Bonn, Dept Radiol, D-53127 Bonn, Germany
关键词
D O I
10.1532/HSF98.20041144
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: Invasive, selective coronary angiography is the gold standard for evaluation of coronary artery disease ( CAD) and degree of stenosis. The purpose of this study was to compare 3-dimensional (3D) reconstructed 16-slice multislice computed tomographic (MSCT) angiography and selective coronary angiography in patients before elective coronary artery bypass graft (CABG) procedure. Methods: Sixteen-slice MSCT scans (Philips Mx8000 IDT) were performed in 50 patients ( 42 male/8 female; mean age, 64.44 +/- 8.66 years) scheduled for elective CABG procedure. Scans were retrospectively electrocardiogram-gated 3D reconstructed. The images of the coronary arteries were evaluated for stenosis by 2 independent radiologists. The results were compared with the coronary angiography findings using the American Heart Association segmental classification for coronary arteries. Results: Four patients (8%) were excluded for technical reasons. Thirty-eight patients (82.6%) had 3-vessel disease, 4 (8.7%) had 2-vessel disease, and 4 ( 8.7%) had an isolated left anterior descending artery stenosis. In the proximal segments all stenoses > 50% (56/56) were detected by MSCT; medial segment sensitivity was 97% (73/75), specificity 90.3%; distal segment sensitivity was 90.7% (59/65), specificity 77%. Conclusion: Accurate quanti. cation of coronary stenosis greater than 50% in the proximal and medial segments is possible with high sensitivity and specificity using the new generation of 16-slice MSCTs. There is still a tendency to overestimate stenosis in the distal segments. MSCT seems to be an excellent diagnostic tool for screening patients with possible CAD.
引用
收藏
页码:E42 / E46
页数:5
相关论文
共 50 条
  • [1] The accuracy of 4-slice computer tomography and 16-slice computer tomography in the detection and quantification of significant (50%) coronary artery stenosis in comparison with coronary angiography
    Pasowicz, M
    Klimeczek, P
    Zajdel, W
    Bany, R
    Zmudka, K
    EUROPEAN HEART JOURNAL, 2004, 25 : 117 - 117
  • [2] Validation of non-invasive coronary angiography by 16-slice multidetector spiral computed tomography in comparison to invasive coronary angiography
    Kaiser, C
    Pater, S
    Bremerich, J
    Bongartz, G
    Steinbrich, W
    Pfisterer, M
    Buser, P
    EUROPEAN HEART JOURNAL, 2003, 24 : 725 - 725
  • [3] Validation of non-invasive coronary angiography by 16-slice multidetector spiral computed tomography in comparison to invasive coronary angiography
    Kaiser, C
    Pater, S
    Bremerich, J
    Bongartz, G
    Steinbrich, W
    Pfisterer, M
    Buser, P
    CIRCULATION, 2003, 108 (17) : 672 - 672
  • [4] Noninvasive Detection of Coronary Artery Stenosis Using 16-slice Spiral CT: a Comparison with Selective X-ray Coronary Angiography
    史河水
    韩萍
    孔祥泉
    冯敢生
    Martin HK Hoffmann
    华中科技大学学报(医学英德文版), 2006, (03) : 338 - 340
  • [5] Noninvasive detection of coronary artery stenosis using 16-slice spiral CT: A comparison with selective X-ray coronary angiography
    Shi Heshui
    Han Ping
    Kong Xiangquan
    Feng Gangsheng
    Martin HK Hoffmann
    Journal of Huazhong University of Science and Technology [Medical Sciences], 2006, 26 (3): : 338 - 340
  • [6] Diagnostic accuracy of 16-slice CT coronary angiography in the evaluation of coronary artery disease
    Soon, K. H.
    Chaitowitz, I.
    Cox, N.
    MacGregor, L.
    Eccleston, D.
    Bell, K. W.
    Kelly, A-M
    Lim, Y. L.
    AUSTRALASIAN RADIOLOGY, 2007, 51 (04): : 365 - 369
  • [7] CABG patients: better coronary CT before invasive coronary angiography?
    Dahm, Johannes B.
    AKTUELLE KARDIOLOGIE, 2024, 13 (01)
  • [8] Coronary stenosis detection by 16-slice computed tomography in heart transplanted patients: Comparison with conventional coronary angiography and impact on clinical management
    Romeo, G
    Houyel, L
    Paul, JF
    Brenot, P
    Riou, JY
    Angel, CY
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (03) : 283A - 283A
  • [9] Comparison of 16-Slice Computed Tomography with Conventional Angiography to Evaluate Coronary Artery Stent Patency
    Durur-Subasi, Irmak
    Kantarci, Mecit
    Durur-Karakaya, Afak
    Okur, Adnan
    EURASIAN JOURNAL OF MEDICINE, 2009, 41 (01) : 4 - 9
  • [10] Coronary Angiography by 16-Slice Computed Tomography Prior to Valvular Surgery
    Rodriguez-Palomares, Jose F.
    Cuellar, Hug
    Marti, Gerard
    Garcia, Bruno
    Teresa Gonzalez-Alujas, M.
    Mahia, Patricia
    Evangelista, Arturo
    Tornos, Pilar
    Garcia-Dorado, David
    REVISTA ESPANOLA DE CARDIOLOGIA, 2011, 64 (04): : 269 - 276