Cracking and impingement in ultra-high-molecular-weight polyethylene acetabular liners

被引:39
作者
Birman, MV
Noble, PC
Conditt, MA
Li, S
Mathis, KB
机构
[1] Baylor Coll Med, Dept Orthoped Surg, Houston, TX 77030 USA
[2] Adv Technol Orthot, Boerne, TX USA
[3] Med Device Testing & Innovat LLC, Sarasota, FL USA
关键词
hip arthroplasty; retrieval; impingement oxidation; cross-linked polyethylene; wear;
D O I
10.1016/j.arth.2005.05.001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this Study was to determine the prevalence of crack formation in conventional Ultra-high-molecular-weight polyethylene cups and its association with rim impingement, oxidation, and time in situ. One hundred twenty acetabular cups were retrieved during revision total hip arthroplasty. in 40% (48/120) of the retrieved specimens, multiple Subsurface cracks of several millimeters in length were revealed by transillumination. In 5 specimens, full thickness cracks led to fragmentation of the liner before revision. Thirty-eight (32%) liners had regions of moderate to severe impingement damage to the rim; cracks were initiated at the site of impingement in all but 1 liner (P <.0001). Cracks commonly occur in conventional ultra-high-molecular-weight polyethylene liners, often after neck impingement and almost always in association with oxidation of the polymer.
引用
收藏
页码:87 / 92
页数:6
相关论文
共 18 条
[1]  
Baker DA, 1999, J BIOMED MATER RES, V46, P573, DOI 10.1002/(SICI)1097-4636(19990915)46:4<573::AID-JBM16>3.0.CO
[2]  
2-A
[3]   The effects of degree of crosslinking on the fatigue crack initiation and propagation resistance of orthopedic-grade polyethylene [J].
Baker, DA ;
Bellare, A ;
Pruitt, L .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2003, 66A (01) :146-154
[4]   Effect of oxidation on delamination of ultrahigh-molecular-weight polyethylene tibial components [J].
Bell, CJ ;
Walker, PS ;
Abeysundera, MR ;
Simmons, JMH ;
King, PM ;
Blunn, GW .
JOURNAL OF ARTHROPLASTY, 1998, 13 (03) :280-290
[5]  
Collier JP, 1998, ORTHOPEDICS, V21, P865
[6]   Biomechanics of large femoral heads - What they do and don't do [J].
Crowninshield, RD ;
Maloney, WJ ;
Wentz, DH ;
Humphrey, SM ;
Blanchard, CR .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2004, (429) :102-107
[7]  
FURMAN B, 2002, 48 ANN M ORTH RES SO
[8]   Failure micromechanisms during uniaxial tensile fracture of conventional and highly crosslinked ultra-high molecular weight polyethylenes used in total joint replacements [J].
Gencur, SJ ;
Rimnac, CM ;
Kurtz, SM .
BIOMATERIALS, 2003, 24 (22) :3947-3954
[9]  
Hall R M, 1998, J Orthop Sci, V3, P204, DOI 10.1007/s007760050043
[10]   RETRIEVAL ANALYSIS OF TOTAL KNEE PROSTHESES - A METHOD AND ITS APPLICATION TO 48 TOTAL CONDYLAR PROSTHESES [J].
HOOD, RW ;
WRIGHT, TM ;
BURSTEIN, AH .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1983, 17 (05) :829-842