ANN-based adaptive current controller for on-grid DG system to meet frequency deviation and transient load challenges with hardware implementation

被引:19
作者
Patowary, Moushumi [1 ]
Panda, Gayadhar [1 ]
Naidu, Bonu Ramesh [1 ]
Deka, Bimal C. [2 ]
机构
[1] NIT Meghalaya, Dept Elect Engn, Bijni Complex, Shillong 793003, Meghalaya, India
[2] Assam Engn Coll, Dept Elect Engn, Gauhati 781013, Assam, India
关键词
neurocontrollers; adaptive control; electric current control; distributed power generation; power convertors; least mean squares methods; power generation control; LC filter; grid disturbances; variable leaky adaptive step-size-least mean square control algorithm; artificial neural network; power quality; on-grid voltage source converter system; distributed generations reliability; transient load; frequency deviation; on-grid DG system; ANN-based adaptive current controller; NEURAL-NETWORK; POWER; SCHEME; CONVERTERS;
D O I
10.1049/iet-rpg.2017.0142
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
To maximise functional efficacy and reliability of distributed generations (DGs), this study leads to modelling, control, stability analysis, and hardware validation of a new adaptive current controller in the application of an on-grid voltage source converter (VSC) system. For effective mitigation of power system hindrances without affecting the power quality (PQ), self-tuning of weights associated with the proposed variable leaky adaptive step-size-least mean square (VLAS-LMS) control algorithm based on artificial neural network (ANN) is updated in natural frame and felicitous shaping of VSC outputs are witnessed. The selection of a constant step-size associated with proposed controller usually yields updating of same weights by all the sampling periods and hardly takes care of rate of convergence factor, which decides the stability of the controller. It can no longer avoid wavering of weights during grid disturbances, resulting in high-filtering gains. Again, a constant leaky factor may lead to over- or under-parameterisation of regularisation component. These disputes can be overcome in the proposed algorithm by the introduction of an adaptive step size along with a variable leaky factor. Furthermore, PQ is maintained as trade-off by the inclusion of detuned LC filter. Experimental outcome ensures the validation and effectiveness of the proposed controller.
引用
收藏
页码:61 / 71
页数:11
相关论文
共 30 条
[1]  
[Anonymous], 2007, Instantaneous Power Theory and Applications to Power Conditioning
[2]  
[Anonymous], 2000, 9292000 IEEE
[3]  
Azevedo G.M.S, 2015, IEEE INT C IND TECHN, P2841
[4]   A novel common power factor correction scheme for homes and offices [J].
Basu, S ;
Bollen, MHJ .
IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (03) :2257-2263
[5]  
Benadli R., 2015, 6 INT REN EN C IREC, P1
[6]   A Review of Passive Power Filters for Three-Phase Grid-Connected Voltage-Source Converters [J].
Beres, Remus Narcis ;
Wang, Xiongfei ;
Liserre, Marco ;
Blaabjerg, Frede ;
Bak, Claus Leth .
IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2016, 4 (01) :54-69
[7]   Power electronics as efficient interface in dispersed power generation systems [J].
Blaabjerg, F ;
Chen, Z ;
Kjaer, SB .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2004, 19 (05) :1184-1194
[8]   UPDATE OF HARMONIC STANDARD IEEE-519 - IEEE RECOMMENDED PRACTICES AND REQUIREMENTS FOR HARMONIC CONTROL IN ELECTRIC-POWER SYSTEMS [J].
DUFFEY, CK ;
STRATFORD, RP .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1989, 25 (06) :1025-1034
[9]   Control of Single-Phase Grid-Connected Converters With LCL Filters Using Recurrent Neural Network and Conventional Control Methods [J].
Fu, Xingang ;
Li, Shuhui .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2016, 31 (07) :5354-5364
[10]   Fast and accurate measurement of harmonic parameters employing hybrid adaptive linear neural network and filtered-x least mean square algorithm [J].
Garanayak, Priyabrat ;
Panda, Gayadhar .
IET GENERATION TRANSMISSION & DISTRIBUTION, 2016, 10 (02) :421-436