Multiwalled-carbon nanotubes reinforced hydroxyapatite- tantalum pentoxide nanocomposite coating on Nitinol alloy: Antibacterial activity and Electrochemical properties

被引:11
作者
Horandghadim, Nazila [1 ]
Ghazanfar-Ahari, Yashar [1 ]
Khalil-Allafi, Jafar [1 ]
机构
[1] Sahand Univ Technol, Fac Mat Engn, Res Ctr Adv Mat, Tabriz, Iran
基金
美国国家科学基金会;
关键词
NiTi shape memory alloy; Hydroxyapatite-tantalum pentoxide-multiwalled carbon nanotubes coating; Electrophoretic deposition; Adhesion strength; Antibacterial activity; Electrochemical behavior; ELECTROPHORETIC DEPOSITION; MECHANICAL-PROPERTIES; ANTIMICROBIAL ACTIVITY; CORROSION BEHAVIOR; COMPOSITE COATINGS; BONE-IMPLANT; NANO-TUBES; SURFACE; BIOCOMPATIBILITY; POLYMER;
D O I
10.1016/j.surfin.2022.101773
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
In this work to establish the antibacterial implants, the different amounts of multi-walled carbon nanotubes (MWCNTs, 0.5, 1, 1.5, and 2 wt.%) were incorporated with hydroxyapatite-tantalum pentoxide (HA-Ta2O5) and exerted on the NiTi by electrophoretic deposition (EPD) method. The increased HA-Ta2O5 coating density by adding and enhancing the MWCNTs content was shown by field emission scanning electron microscope (FESEM) and atomic force microscopy (AFM). It was affirmed that MWCNTs have still been stable in HA-Ta2O5_MWCNTs coatings after sintering at 700 degrees C for 1 h. The increase of MWCNTs from 0.5 to 2 wt.% caused an increment of adhesion strength of HA-Ta2O5 coating to NiTi from 10 to 27% due to providing the more contact surface area of the coating with substrate and consequently the higher chemical bonding. It was found that the antibacterial property of the HA-Ta2O5 coating was induced by MWCNTs. Such behavior originated from the antibacterial characteristic of MWCNTs and has successively improved due to the rise in MWCNTs content and concurrent diminish in HA-Ta2O5_MWCNTs surface wettability. The positive effect of MWCNTs on the electrochemical behavior of HA-Ta2O5-coated NiTi was confirmed by polarization test and electrochemical impedance spectroscopy (EIS). According to the parameters resulted from the fitting of EIS spectra with the electrical circuits (EC), the resistances of the coating and the double-layer on NiTi surface have increased due to an enhancement in the MWCNTs content. This improvement was attributed to the increased density and reduced wettability of HA-Ta2O5 coating.
引用
收藏
页数:16
相关论文
共 81 条
  • [41] Electrophoretic deposition of HA/MWNTs composite coating for biomaterial applications
    Lin, Changjian
    Han, Huijuan
    Zhang, Fang
    Li, Aimin
    [J]. JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2008, 19 (07) : 2569 - 2574
  • [42] An electrochemical impedance spectroscopy study of the corrosion behaviour of PVD coated steels in 0.5 N NaCl aqueous solution: Part II. EIS interpretation of corrosion behaviour
    Liu, C
    Bi, Q
    Leyland, A
    Matthews, A
    [J]. CORROSION SCIENCE, 2003, 45 (06) : 1257 - 1273
  • [43] Structural characterization, mechanical, and electrochemical studies of hydroxyapatite-titanium composite coating fabricated using electrophoretic deposition and reaction bonding process
    Maleki-Ghaleh, Hossein
    Khalil-Allafi, Jafar
    Horandghadim, Nazila
    Keikhosravani, Pardis
    Hosseini, Mir Ghasem
    [J]. JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2020, 108 (05) : 2119 - 2130
  • [44] The microstructural features and corrosion behavior of Hydroxyapatite/ ZnO nanocomposite electrodeposit on NiTi alloy: Effect of current density
    Mehrvarz, Alireza
    Ghazanfar-Ahari, Yashar
    Khalil-Allafi, Jafar
    Mahdavi, Soheil
    Etminanfar, Mohamadreza
    [J]. CERAMICS INTERNATIONAL, 2022, 48 (02) : 2191 - 2202
  • [45] Meredith Jay Russell, 2013, Front Biosci (Elite Ed), V5, P610
  • [46] Enhanced bioactivity of 316L stainless steel with deposition of polypyrrole/hydroxyapatite layered hybrid coating: Orthopedic applications
    Mohandesnezhad, Sadaf
    Etminanfar, Mohamadreza
    Mahdavi, Soheil
    Safavi, Mir Saman
    [J]. SURFACES AND INTERFACES, 2022, 28
  • [47] In Vitro Biological Characterization of Natural Hydroxyapatite/Single-Walled Carbon Nanotube Composite Coatings Synthesized by Electrophoretic Deposition on NiTi Shape Memory Alloy
    Nematzadeh, Leila
    Horandghadim, Nazila
    Khalili, Vida
    Khalil-Allafi, Jafar
    [J]. JOURNAL OF MATERIALS ENGINEERING AND PERFORMANCE, 2020, 29 (09) : 6170 - 6180
  • [48] A new complex ceramic coating with carbon nano-tubes, hydroxyapatite and TiO2 nanotubes on Ti surface for biomedical applications
    Prodana, Mariana
    Duta, Marius
    Ionita, Daniela
    Bojin, Dionezie
    Stan, Miruna S.
    Dinischiotu, Anca
    Demetrescu, Ioana
    [J]. CERAMICS INTERNATIONAL, 2015, 41 (05) : 6318 - 6325
  • [49] Synthesis of Ag/CNT hybrid nanoparticles and fabrication of their Nylon-6 polymer nanocomposite fibers for antimicrobial applications
    Rangari, Vijaya K.
    Mohammad, Ghouse M.
    Jeelani, Shaik
    Hundley, Angel
    Vig, Komal
    Singh, Shree Ram
    Pillai, Shreekumar
    [J]. NANOTECHNOLOGY, 2010, 21 (09)
  • [50] Evaluation of TiO2 Nanoparticles Concentration and Applied Current Density Role in Determination of Microstructural, Mechanical, and Corrosion Properties of Ni-Co Alloy Coatings
    Rasooli, Ali
    Safavi, Mir Saman
    Ahmadiyeh, Somayeh
    Jalali, Akram
    [J]. PROTECTION OF METALS AND PHYSICAL CHEMISTRY OF SURFACES, 2020, 56 (02) : 320 - 327