Phytochemical Characterization for Quality Control of Phyllostachys pubescens Leaves Using High-Performance Liquid Chromatography Coupled with Diode Array Detector and Tandem Mass Detector

被引:4
|
作者
Seo, Chang-Seob [1 ]
Song, Kwang-Hoon [2 ]
机构
[1] Korea Inst Oriental Med, KM Sci Res Div, Yuseong Daero 1672, Daejeon 34054, South Korea
[2] Korea Inst Oriental Med, KM Convergence Res Div, Yuseong Daero 1672, Daejeon 34054, South Korea
来源
PLANTS-BASEL | 2022年 / 11卷 / 01期
关键词
quality assessment; bamboo; LC-MS; MS; method validation; BAMBOO LEAVES; QUANTITATIVE-ANALYSIS; CHLOROGENIC ACIDS; CONSTITUENTS; EXTRACTS; ANTIOXIDANT; FLAVONOIDS; WATER;
D O I
10.3390/plants11010050
中图分类号
Q94 [植物学];
学科分类号
071001 ;
摘要
Phyllostachys pubescens leaves are cultivated in a number of Asian countries and have been used for antipyretic and diuretic effects since ancient times, especially in Korea. The purpose of this study was to develop and validate of analytical method for quality control of P. pubescens leaves using high-performance liquid chromatography with diode array detector (HPLC-DAD) and liquid chromatography with tandem mass spectrometry (LC-MS/MS) detection. HPLC-DAD analysis was conducted with a Gemini C-18 column, and distilled water-acetonitrile (both with 0.1% (v/v) formic acid) mobile-phase system. For the LC-MS/MS analysis, all markers were separated with a Waters ACQUITY UPLC BEH C-18 column and gradient flow system of distilled water containing 0.1% (v/v) formic acid and 5 mM ammonium formate-acetonitrile. In both method, major components were detected at 2.13-11.63 mg/g (HPLC-DAD) and 0.12-19.20 mg/g (LC-MS/MS). These methods were validated with respect to linearity (coefficient of determination >0.99), recovery (95.22-118.81%), accuracy (90.52-116.96), and precision (<4.0%), and were successfully applied for the quantitative analysis of P. pubescens leaves.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Quality evaluation of Hpericum japomicum by using high-performance liquid chromatography coupled with photodiode array detector and electrospray ionization tandem mass spectrometry
    Gao, Wei-Na
    Luo, Jian-Guang
    Kong, Ling-Yi
    BIOMEDICAL CHROMATOGRAPHY, 2009, 23 (09) : 1022 - 1030
  • [2] Quality and antioxidant activity detection of Crataegus leaves using on-line high-performance liquid chromatography with diode array detector coupled to chemiluminescence detection
    Ding, Xiao-Ping
    Wang, Xin-Tang
    Chen, Lin-Lin
    Qi, Jin
    Xu, Tian
    Yu, Bo-Yang
    FOOD CHEMISTRY, 2010, 120 (03) : 929 - 933
  • [3] Quality evaluation of Rhizoma Belamcandae (Belamcanda chinensis (L.) DC.) by using high-performance liquid chromatography coupled with diode array detector and mass spectrometry
    Li, Jun
    Li, Winnie Z. M.
    Huang, Wen
    Cheung, Anna W. H.
    Bi, Cathy W. C.
    Duan, Ran
    Guo, Ava J. Y.
    Dong, Tina T. X.
    Tsim, Karl W. K.
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (11) : 2071 - 2078
  • [4] Improved quantification of mass fraction of colorants in textile by high-performance liquid chromatography coupled with tandem mass spectrometric detector
    Tolgyesi, Adam
    Sharma, Virender K.
    Kulati, Anita
    ACCREDITATION AND QUALITY ASSURANCE, 2020, 25 (04) : 259 - 272
  • [5] Determination of flibanserin and tadalafil in supplements for women sexual desire enhancement using high-performance liquid chromatography with tandem mass spectrometer, diode array detector and charged aerosol detector
    Poplawska, Magdalena
    Blazewicz, Agata
    Zolek, Paulina
    Fijalek, Zbigniew
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2014, 94 : 45 - 53
  • [6] Development and validation of a rapid ultra-high performance liquid chromatography diode array detector method for Verbena officinalis L.
    Gibitz-Eisath, Nora
    Eichberger, Miriam
    Gruber, Regina
    Sturm, Sonja
    Stuppner, Hermann
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2018, 160 : 160 - 167
  • [7] Characterization of flavonoids in the extract of Sophora flavescens Ait by high-performance liquid chromatography coupled with diode-array detector and electrospray ionization mass spectrometry
    Zhang, Lei
    Xu, Liang
    Xiao, Shan-Shan
    Liao, Qiong-Feng
    Li, Qing
    Liang, Jian
    Chen, Xiao-Hui
    Bi, Kai-Shun
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2007, 44 (05) : 1019 - 1028
  • [8] High-performance liquid chromatography using diode array detector and fluorescence detector for hydrogen peroxide analysis in processed fishery foods
    Park, Juhee
    Noh, Heemin
    Suh, Hee-Jae
    Ryu, Dojin
    Lee, Hyun Jung
    Lee, Chan
    FOOD SCIENCE AND BIOTECHNOLOGY, 2023, 32 (01) : 27 - 37
  • [9] High-performance liquid chromatography using diode array detector and fluorescence detector for hydrogen peroxide analysis in processed fishery foods
    Juhee Park
    Heemin Noh
    Hee-Jae Suh
    Dojin Ryu
    Hyun Jung Lee
    Chan Lee
    Food Science and Biotechnology, 2023, 32 : 27 - 37
  • [10] A simple and robust high-performance liquid chromatography coupled to a diode-array detector method for the analysis of genistein in mouse tissues
    Tamames-Tabar, C.
    Imbuluzqueta, E.
    Campanero, M. A.
    Horcajada, P.
    Blanco-Prieto, M. J.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2013, 935 : 47 - 53