Comparison of common components analysis with principal components analysis and independent components analysis: Application to SPME-GC-MS volatolomic signatures

被引:27
作者
Bouhlel, Jihene [1 ,2 ]
Bouveresse, Delphine Jouan-Rimbaud [1 ]
Abouelkaram, Said [2 ]
Baeza, Elisabeth [3 ]
Jondreville, Catherine [3 ]
Travel, Angelique [3 ]
Ratel, Jeremy [2 ]
Engel, Erwan [2 ]
Rutledge, Douglas N. [1 ]
机构
[1] Univ Paris Saclay, INRA, AgroParisTech, UMR Ingn Proc Aliments, F-91300 Massy, France
[2] INRA, UR QuaPA 370, MASS Lab, St Genes Champanelle, France
[3] INRA, Ctr Val Loire, Rech Avicoles UR83, ITAVI, F-37380 Nouzilly, France
关键词
Common Components Analysis (CCA); Independent Components Analysis (ICA); Principal Components Analysis (PCA); SPME-GC-MS; Volatolomic; Liver markers; VOLATILE ORGANIC-COMPOUNDS; LUNG-CANCER; BIOMARKERS; RESPONSES; EXPOSURE; LIVER; RATS;
D O I
10.1016/j.talanta.2017.10.025
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The aim of this work is to compare a novel exploratory chemometrics method, Common Components Analysis (CCA), with Principal Components Analysis (PCA) and Independent Components Analysis (ICA). CCA consists in adapting the multi-block statistical method known as Common Components and Specific Weights Analysis (CCSWA or ComDim) by applying it to a single data matrix, with one variable per block. As an application, the three methods were applied to SPME-GC-MS volatolomic signatures of livers in an attempt to reveal volatile organic compounds (VOCs) markers of chicken exposure to different types of micropollutants. An application of CCA to the initial SPME-GC-MS data revealed a drift in the sample Scores along CC2, as a function of injection order, probably resulting from time-related evolution in the instrument. This drift was eliminated by orthogonalization of the data set with respect to CC2, and the resulting data are used as the orthogonalized data input into each of the three methods. Since the first step in CCA is to norm-scale all the variables, preliminary data scaling has no effect on the results, so that CCA was applied only to orthogonalized SPME-GC-MS data, while, PCA and ICA were applied to the "orthogonalized", "orthogonalized and Paretoscaled", and "orthogonalized and autoscaled" data. The comparison showed that PCA results were highly dependent on the scaling of variables, contrary to ICA where the data scaling did not have a strong influence. Nevertheless, for both PCA and ICA the clearest separations of exposed groups were obtained after autoscaling of variables. The main part of this work was to compare the CCA results using the orthogonalized data with those obtained with PCA and ICA applied to orthogonalized and autoscaled variables. The clearest separations of exposed chicken groups were obtained by CCA. CCA Loadings also clearly identified the variables contributing most to the Common Components giving separations. The PCA Loadings did not highlight the most influencing variables for each separation, whereas the ICA Loadings highlighted the same variables as did CCA. This study shows the potential of CCA for the extraction of pertinent information from a data matrix, using a procedure based on an original optimisation criterion, to produce results that are complementary, and in some cases may be superior, to those of PCA and ICA.
引用
收藏
页码:854 / 863
页数:10
相关论文
共 35 条
[1]   An Introduction to Liquid Chromatography-Mass Spectrometry Instrumentation Applied in Plant Metabolomic Analyses [J].
Allwood, J. William ;
Goodacre, Royston .
PHYTOCHEMICAL ANALYSIS, 2010, 21 (01) :33-47
[2]   Evaluation and physiological correlation of plasma proteomic fingerprints for deltamethrin-induced hepatotoxicity in Wistar rats [J].
Arora, Deepika ;
Siddiqui, Mohammed Haris ;
Sharma, Pradeep Kumar ;
Singh, Sheelendra Pratap ;
Tripathi, Anurag ;
Mandal, Payal ;
Singh, Uma Shankar ;
Singh, Pradhyumna Kumar ;
Shukla, Yogeshwer .
LIFE SCIENCES, 2016, 160 :72-83
[3]   Understanding different facets of cardiovascular diseases based on model systems to human studies: A proteomic and metabolomic perspective [J].
Basak, Trayambak ;
Varshney, Swati ;
Akhtar, Shamima ;
Sengupta, Shantanu .
JOURNAL OF PROTEOMICS, 2015, 127 :50-60
[4]  
Bedini L., 2007, LECT NOTES COMPUTER, V4694
[5]   Plasmatic concentration of organochlorine lindane acts as metabolic disruptors in HepG2 liver cell line by inducing mitochondrial disorder [J].
Benarbia, Mohammed el Amine ;
Macherel, David ;
Faure, Sebastien ;
Jacques, Caroline ;
Andriantsitohaina, Ramaroson ;
Malthiery, Yves .
TOXICOLOGY AND APPLIED PHARMACOLOGY, 2013, 272 (02) :325-334
[6]   Use of Volatile Compound Metabolic Signatures in Poultry Liver to Back-Trace Dietary Exposure to Rapidly Metabolized Xenobiotics [J].
Berge, Philippe ;
Ratel, Jeremy ;
Fournier, Agnes ;
Jondreville, Catherine ;
Feidt, Cyril ;
Roudaut, Brigitte ;
Le Bizec, Bruno ;
Engel, Erwan .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2011, 45 (15) :6584-6591
[7]   Examination of the potential for using chemical analysis as a surrogate for sensory analysis [J].
Blackman, John ;
Rutledge, Douglas N. ;
Tesic, Dejan ;
Saliba, Anthony ;
Scollary, Geoffrey R. .
ANALYTICA CHIMICA ACTA, 2010, 660 (1-2) :2-7
[8]   Solid-phase microextraction set-up for the analysis of liver volatolome to detect livestock exposure to micropollutants [J].
Bouhlel, Jihene ;
Ratel, Jeremy ;
Abouelkaram, Said ;
Mercier, Frederic ;
Travel, Angelique ;
Baeza, Elisabeth ;
Jondreville, Catherine ;
Dervilly-Pinel, Gaud ;
Marchand, Philippe ;
Le Bizec, Bruno ;
Dubreil, Estelle ;
Mompelat, Sophie ;
Verdon, Eric ;
Inthavong, Chanthadary ;
Guerin, Thierry ;
Rutledge, Douglas N. ;
Engel, Erwan .
JOURNAL OF CHROMATOGRAPHY A, 2017, 1497 :9-18
[9]  
Demartines P., 1996, TR96036 INT COMP SCI
[10]   Common components and specific weights analysis: A tool for metabolomic data pre-processing [J].
Dubin, Elodie ;
Spiteri, Marc ;
Dumas, Anne-Sophie ;
Ginet, Jerome ;
Lees, Michele ;
Rutledge, Douglas N. .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 2016, 150 :41-50