Agreement of high definition oscillometry with direct arterial blood pressure measurement at different blood pressure ranges in horses under general anaesthesia

被引:25
作者
Tuensmeyer, Julia [1 ]
Hopster, Klaus [2 ]
Feige, Karsten [2 ]
Kaestner, Sabine B. R. [1 ,2 ]
机构
[1] Univ Vet Med Hannover, Small Anim Clin, Hannover, Germany
[2] Univ Vet Med Hannover, Clin Horses, Hannover, Germany
关键词
arterial blood pressure; cardiovascular; equine; oscillometry; ANESTHETIZED DOGS; NEONATAL FOALS; MONITOR; DEVICES;
D O I
10.1111/vaa.12203
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
ObjectiveTo determine the agreement of high definition oscillometry (HDO) with direct arterial blood pressure measurements in normotensive, hypotensive and hypertensive horses during general anaesthesia. Study designExperimental study. AnimalsSeven healthy warmblood horses, aged 3-11years, weighing 470-565kg. MethodsMeasurements from a HDO device with the cuff placed around the base of the tail were compared with pressures measured invasively from the facial artery. High blood pressures were induced by intravenous (IV) administration of dobutamine (5g kg(-1)minute(-1)) over ten minutes followed by norepinephrine (0.1mgkg(-1) IV) and low pressures by increasing the inspired fraction of isoflurane and administration of nitroglycerine (0.05mgkg(-1) IV). For analysis three pressure levels were determined: high (MAP>110mmHg), normal (60mmHg<MAP<110mmHg) and low (MAP< 60mmHg). Bland-Altman analysis was used for comparison between non-invasive and invasive measurements. ResultsA total of 245 paired measurements of systolic (SAP), mean (MAP) and diastolic (DAP) pressures were obtained. The HDO device underestimated blood pressure at hypertensive and normotensive levels and overestimated blood pressure at hypotensive levels. Best agreement was obtained for SAP and MAP within normotensive limits. At normotension, biasstandard deviation for SAP, MAP and DAP were 0.1 +/- 19.4mmHg, 0.5 +/- 14.0, 4.7 +/- 15.6, respectively. At high pressure levels bias and SD were 26.1 +/- 37.3 (SAP), 4.2 +/- 19.4 (MAP), 1.5 +/- 16.8 (DAP) and at low pressures -20.0 +/- 20.9 (SAP), -11.4 +/- 19.6 (MAP), -4.7 +/- 20.1 (DAP), with HDO measurements at a MAP <50mmHg often failing. Conclusion and clinical relevanceGood agreement with invasive arterial blood pressures was obtained with HDO at normotensive levels in horses. At high and low pressure ranges HDO was unreliable. Therefore, if haemodynamic instability is expected, invasive measurement remains preferable.
引用
收藏
页码:286 / 291
页数:6
相关论文
共 14 条
[1]   Agreement between methods of measurement with multiple observations per individual [J].
Bland, J. Martin ;
Altman, Douglas G. .
JOURNAL OF BIOPHARMACEUTICAL STATISTICS, 2007, 17 (04) :571-582
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   Comparison of ultrasonic Doppler flow monitor, oscillometric, and direct arterial blood pressure measurements in ill dogs [J].
Bosiack, Ann P. ;
Mann, F. A. ;
Dodam, John R. ;
Wagner-Mann, Colette C. ;
Branson, Keith R. .
JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2010, 20 (02) :207-215
[4]   A clinical evaluation of an oscillometric blood pressure monitor on anesthetized horses [J].
Branson, KR .
JOURNAL OF EQUINE VETERINARY SCIENCE, 1997, 17 (10) :537-540
[5]  
Brown C., 1981, Journal of Equine Veterinary Science, V1, P208, DOI [10.1016/S0737-0806(81)80039-1, DOI 10.1016/S0737-0806(81)80039-1]
[6]  
Giguère S, 2005, J VET INTERN MED, V19, P571, DOI 10.1892/0891-6640(2005)19[571:AOIMOB]2.0.CO
[7]  
2
[8]   Sensitivity of two noninvasive blood pressure measurement techniques compared to telemetry in cynomolgus monkeys and beagle dogs [J].
Mitchell, Andrea Z. ;
McMahon, Carrie ;
Beck, Tom W. ;
Sarazan, R. Dustan .
JOURNAL OF PHARMACOLOGICAL AND TOXICOLOGICAL METHODS, 2010, 62 (01) :54-63
[9]   Indirect oscillometric and direct blood pressure measurements in anesthetized and conscious neonatal foals [J].
Nout, YS ;
Corley, KTT ;
Donaldson, LL ;
Furr, MO .
JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2002, 12 (02) :75-80
[10]   WAVE REFLECTIONS AND THE ARTERIAL PULSE [J].
OROURKE, MF ;
YAGINUMA, T .
ARCHIVES OF INTERNAL MEDICINE, 1984, 144 (02) :366-371