Humoral immune response and coated or uncoated oxygenators during cardiopulmonary bypass surgery

被引:1
作者
Karakisi, Sedat Ozan [1 ]
Kunt, Ayse Gul [2 ]
Bozok, Sahin [1 ]
Cankaya, Idil [3 ]
Kocakulak, Mustafa [3 ]
Musabak, Ugur [4 ,5 ]
Sargon, Mustafa Fevzi [6 ]
Ergene, Saban [1 ]
Ilhan, Gokhan [1 ]
Karamustafa, Hakan [1 ]
Tufekci, Nebiye [1 ]
Sener, Erol [2 ]
机构
[1] Recep Tayyip Erdogan Univ, Training & Res Hosp, Fac Med, Dept Cardiovasc Surg, Rize, Turkey
[2] Yildirim Beyazid Univ, Ataturk Training & Res Hosp, Fac Med, Dept Cardiovasc Surg, Ankara, Turkey
[3] Baskent Univ, Dept Biomed Engn, Ankara, Turkey
[4] Gulhane Mil Med Acad, Dept Immunol, Ankara, Turkey
[5] Sch Med, Ankara, Turkey
[6] Hacettepe Univ, Fac Med, Dept Anat, Ankara, Turkey
关键词
cardiopulmonary bypass; oxygenator; phosphorylcholine; humoral inflammation; INFLAMMATORY RESPONSE; EXTRACORPOREAL CIRCUITS; COMPLEMENT ACTIVATION; CARDIAC-SURGERY; BIOCOMPATIBILITY; HEPARIN; SURFACE; MODEL;
D O I
10.5830/CVJA-2016-003
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim: To investigate and compare uncoated and phosphoryl-choline-coated oxygenators in terms of induction of humoral immune response during coronary artery bypass surgery. Methods: A total of 20 consecutive patients who underwent coronary artery bypass surgery were randomly distributed into two groups according to the type of oxygenator used during surgery. Group 1 consisted of 10 patients who were operated on using phosphorylcholine-coated oxygenators. Group 2 contained 10 patients who underwent surgery using uncoated oxygenators. Blood and oxygenator fibre samples were obtained and compared in terms of immunoglobulins (IgG, IgM), complements (C3c, C4), serum total protein and albumin levels using electron microscopy and flow cytometry. Results: In group 1, levels of IgM, IgG, total protein and serum albumin were significantly increased at the end of cardiopulmonary bypass (CPB) compared to those at the beginning of CPB. In group 2, C3c and C4 levels at the beginning of CPB were found to be significantly higher than at the end. Electron microscopic examination of oxygenator fibres demonstrated that phosphorylcholine-coated fibres were less likely to be adsorbed by serum proteins and complements than the uncoated fibres. Conclusion: Our results indicate that phosphorylcholine-coated oxygenators seemed to induce humoral immune response to a lesser extent than uncoated oxygenators during coronary artery bypass procedures.
引用
收藏
页码:242 / 245
页数:4
相关论文
共 18 条
  • [1] In vitro evaluation of new surface coatings for extracorporeal circulation
    Baksaas, ST
    Videm, V
    Fosse, E
    Karlsen, H
    Pedersen, T
    Mollnes, TE
    Hagve, TA
    Svennevig, JL
    [J]. PERFUSION-UK, 1999, 14 (01): : 11 - 19
  • [2] COMPLEMENT ACTIVATION DURING CARDIOPULMONARY BYPASS - EVIDENCE FOR GENERATION OF C3A AND C5A ANAPHYLATOXINS
    CHENOWETH, DE
    COOPER, SW
    HUGLI, TE
    STEWART, RW
    BLACKSTONE, EH
    KIRKLIN, JW
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1981, 304 (09) : 497 - 503
  • [3] Phosphorylcholine coating of extracorporeal circuits provides natural protection against blood activation by the material surface
    De Somer, F
    François, K
    van Oeveren, W
    Poelaert, J
    De Wolf, D
    Ebels, T
    Van Nooten, G
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2000, 18 (05) : 602 - 606
  • [4] Clinical significance of coated extracorporeal circuits: a review of novel technologies
    Gunaydin, S
    [J]. PERFUSION-UK, 2004, 19 : S33 - S41
  • [5] Gunaydin S., 2004, CURR MED CHEM CARDIO, V2, P187
  • [6] Karakisi S, 2015, PERFUSION
  • [7] Laffey JG, 2002, ANESTHESIOLOGY, V97, P215
  • [8] Immunoglobulin levels and lymphocyte subsets following cardiac operations: Further evidence for a T-helper cell shifting
    Lante, W
    Franke, A
    Weinhold, C
    Markewitz, A
    [J]. THORACIC AND CARDIOVASCULAR SURGEON, 2005, 53 (01) : 16 - 22
  • [9] Larmann Jan, 2004, Best Pract Res Clin Anaesthesiol, V18, P425
  • [10] THE EFFECTS OF COMPLEMENT ACTIVATION DURING CARDIOPULMONARY BYPASS - ATTENUATION BY HYPOTHERMIA, HEPARIN, AND HEMODILUTION
    MOORE, FD
    WARNER, KG
    ASSOUSA, S
    VALERI, CR
    KHURI, SF
    [J]. ANNALS OF SURGERY, 1988, 208 (01) : 95 - 103