Anatomical and radiological study applied to distal radius surgery

被引:24
|
作者
Gasse, N. [1 ]
Lepage, D. [1 ]
Pem, R. [2 ]
Bernard, C. [3 ]
Lerais, J. M. [3 ]
Garbuio, P. [1 ]
Obert, L. [1 ]
机构
[1] Univ Hosp Jean Minjoz, Orthoped Traumatol Plast Reconstruct & Hand Surg, Res Unit, INSERM,EA 4268 I4S IFR 133, F-25000 Besancon, France
[2] Pontarlier Hosp Ctr, Surg Unit, F-25304 Pontarlier, France
[3] Univ Hosp, Radiol A&C Federation, F-25000 Besancon, France
关键词
Distal radius; Volar plate; Anatomy; Dorsal tubercle; Wrist arthroplasty; Fracture; VOLAR PLATE OSTEOSYNTHESIS; INTERNAL-FIXATION; RHEUMATOID WRIST; FRACTURES; RUPTURE; COMPLICATIONS; ARTHROPLASTY; MANAGEMENT; SYSTEM; SCREW;
D O I
10.1007/s00276-010-0754-x
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
The purpose of this study was to determine, during anterior plating of the distal radius, the length of a screw above which there is a risk for the extensor tendons and the optimal shape of an anterior plate. It was also to determine the projection of the axis of the distal third of the radius on the distal articular surface in case of wrist arthroplasty in order to simplify the procedure. We studied 74 dry radii from adult cadavers. Each one underwent a CT scan. We measured the thickness of each radius at the dorsal tubercle level, at the second compartment level and at the third compartment level. We calculated the metaphyseal-epiphyseal angles of the lateral column and of the intermediate column (Rikli and Regazzoni in J Bone Joint Surg (Br) 78(4):588-592, 1996). We also calculated the projection of the longitudinal axis of the most distal 7 cm of the radius on the distal carpal surface of the radius. Mean thickness at the dorsal tubercle level was 22.1 mm (18-26.1). The mean slope of the lateral column was 155A degrees (143-167) while that of the intermediate column was 145A degrees (134-153). We have found a statistically significant difference (p < 0.0001) between these two slopes. The axis of the distal radius was projected on the posterior-lateral quadrant of the distal articular surface. The emergence of new implants needs a precise evaluation of a fractured, an arthritic or a reconstructed distal radius. The double slope of the distal radius complicates the manufacturing of an "anatomical" plate. The optimal shape is between these two slopes. Moreover, ancillaries for wrist replacement are still approximations, which means that it is important to know the projection of the radial axis on the articular surface of the distal radius.
引用
收藏
页码:485 / 490
页数:6
相关论文
共 50 条
  • [21] The Effect of Malnutrition on Postoperative Complications Following Surgery for Distal Radius Fractures
    Wilson, Jacob M.
    Holzgrefe, Russell E.
    Staley, Christopher A.
    Schenker, Mara L.
    Meals, Clifton
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2019, 44 (09): : 742 - 750
  • [22] Functional Outcome of Distal End of Radius Fractures Treated With Volar Plating
    Harish, G.
    JOURNAL OF PHARMACEUTICAL RESEARCH INTERNATIONAL, 2021, 33 (43B) : 50 - 52
  • [23] A Prospective Observational Assessment of Unicortical Distal Screw Placement During Volar Plate Fixation of Distal Radius Fractures
    Dardas, Agnes Z.
    Goldfarb, Charles A.
    Boyer, Martin I.
    Osei, Daniel A.
    Dy, Christopher J.
    Calfee, Ryan P.
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2018, 43 (05): : 448 - 454
  • [24] Distal Radius Malunion
    Katt, Brian
    Seigerman, Daniel
    Lutsky, Kevin
    Beredjiklian, Pedro
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2020, 45 (05): : 433 - 443
  • [25] Intraoperative Detection of Screw Penetration Following Volar Plating of the Distal Radius: A Cadaveric Study Comparing Fluoroscopic Imaging and Ultrasound
    Persitz, Jonathan
    Essa, Ahmad
    Shor, Reut
    Faye-Matthies, Norah
    Von Schroeder, Herb
    Chan, Andrea
    Paul, Ryan
    JOURNAL OF WRIST SURGERY, 2024,
  • [26] Distal radius anatomy applied to the treatment of wrist fractures by plate: a review of recent literature
    Obert, Laurent
    Loisel, Francois
    Gasse, Nicolas
    Lepage, Daniel
    SICOT-J, 2015, 1
  • [27] Nonunion after distal radius fracture: A review
    Liverneaux, P.
    Facca, S.
    Diaz, J. J. Hidalgo
    HAND SURGERY & REHABILITATION, 2016, 35 : S120 - S125
  • [28] A combined randomised and observational study of surgery for fractures in the distal radius in the elderly (CROSSFIRE) - a study protocol
    Harris, Ian A.
    Naylor, Justine M.
    Lawson, Andrew
    Buchbinder, Rachelle
    Ivers, Rebecca
    Balogh, Zsolt
    Smith, Paul
    Mittal, Rajat
    Xuan, Wei
    Howard, Kirsten
    Vafa, Arezoo
    Yates, Piers
    Rieger, Bertram
    Smith, Geoff
    Elkinson, Ilia
    Kim, Woosung
    Chehade, Mellick
    Sungaran, Jai
    Latendresse, Kim
    Wong, James
    Viswanathan, Sameer
    Richardson, Martin
    Shrestha, Kush
    Drobetz, Herwig
    Phong Tran
    Loveridge, Jeremy
    Page, Richard
    Hau, Raphael
    Bingham, Roger
    Mulford, Jonathan
    Incoll, Ian
    BMJ OPEN, 2017, 7 (06):
  • [29] FUNCTIONAL RESULTS AND COMPLICATIONS FOLLOWING LOCKING PALMAR PLATING ON THE DISTAL RADIUS: A RETROSPECTIVE STUDY
    Hakimi, M.
    Jungbluth, P.
    Windolf, J.
    Wild, M.
    JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2010, 35E (04) : 283 - 288
  • [30] Preoperative Depression Is Associated With Increased Complications Following Distal Radius Fracture Surgery
    Broggi, Matthew S.
    Runge, William O.
    Hurt, John T.
    Dawes, Alexander A.
    Toston, Roy J.
    Ojemakinde, Akinade A.
    Cooke, Hayden L.
    Gottschalk, Michael B.
    Wagner, Eric R.
    HAND-AMERICAN ASSOCIATION FOR HAND SURGERY, 2025, 20 (02): : 277 - 283