Molecularly Imprinted Polyaniline Nanowire-Based Electrochemical Biosensor for Chloramphenicol Detection: A Kinetic Study of Aniline Electropolymerization

被引:40
作者
Thi-Xuan Chu [1 ]
Van-Phu Vu [2 ]
Hong-Thuy Tran [1 ]
Thi-Luyen Tran [1 ]
Quang-Thinh Tran [3 ]
Tu Le Manh [4 ,5 ]
机构
[1] Hanoi Univ Sci & Technol, Hanoi 100000, Vietnam
[2] Seoul Natl Univ Sci & Technol, Grad Sch NanoIT Design Fus, Seoul, South Korea
[3] Natl Ctr Technol Progress, Hanoi 100000, Vietnam
[4] Phenikaa Univ, Fac Mat Sci & Engn, PIAS, Hanoi 100000, Vietnam
[5] A&A Green Phoenix Grp, PRATI, Hanoi 100000, Vietnam
关键词
SOLID-PHASE EXTRACTION; POLYPYRROLE NANOWIRES; GOLD NANOPARTICLES; SENSOR; POLYMERS; OXIDE; CONTAMINANTS; VOLTAMMETRY; ADSORPTION; NUCLEATION;
D O I
10.1149/1945-7111/ab6a7e
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
We report a simple and effective approach to develop an electrochemical biosensor based on molecular-imprinted polymer to detect chloramphenicol (CAP). Polyaniline nanowires (PANi NWs) were grown on Au working electrode using cyclic voltammetry (CV) and chronoamperometry (CA). Using CV analysis, several kinetic parameters of interest, such as diffusion coefficient, D, and the heterogeneous standard rate constant, k(0), were determined. The formation of PANi in the electrode occurred through a diffusion-controlled process with slow kinetics. The PANi NWs fabricated with CA were smoother, more homogenous, and showed less agglomeration than those fabricated using CV. CAP was imprinted into the PANi NW network through co-polymerization using CA. CA was used to remove CAP from the PANi NW network in H2SO4 0.5 M solution. The sensor can detect CAP with a limit of 1.24 x 10(-9) M, which is effective for monitoring CAP concentration in aquaculture. (C) 2020 The Electrochemical Society ("ECS"). Published on behalf of ECS by IOP Publishing Limited.
引用
收藏
页数:10
相关论文
共 55 条
[41]   Extraction of hydrocarbon contamination from soils using accelerated solvent extraction [J].
Richter, BE .
JOURNAL OF CHROMATOGRAPHY A, 2000, 874 (02) :217-224
[42]   Molecularly Imprinted Polymer-Based Hybrid Materials for the Development of Optical Sensors [J].
Rico-Yuste, Alberto ;
Carrasco, Sergio .
POLYMERS, 2019, 11 (07)
[43]   Electrochemical detection of an antibiotic drug chloramphenicol based on a graphene oxide/hierarchical zinc oxide nanocomposite [J].
Sebastian, Neethu ;
Yu, Wan-Chin ;
Balram, Deepak .
INORGANIC CHEMISTRY FRONTIERS, 2019, 6 (01) :82-93
[44]   Conducting Polyaniline Nanowire and Its Applications in Chemiresistive Sensing [J].
Song, Edward ;
Choi, Jin-Woo .
NANOMATERIALS, 2013, 3 (03) :498-523
[45]   FATAL CARDIOVASCULAR COLLAPSE OF INFANTS RECEIVING LARGE AMOUNTS OF CHLORAMPHENICOL [J].
SUTHERLAND, JM .
AMA JOURNAL OF DISEASES OF CHILDREN, 1959, 97 (06) :761-767
[46]   Application of ultrasound-assisted extraction to the determination of contaminants in food and soil samples [J].
Tadeo, Jose L. ;
Sanchez-Brunete, Consuelo ;
Albero, Beatriz ;
Garcia-Valcarcel, Ana I. .
JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (16) :2415-2440
[47]   Effective immobilization of DNA for development of polypyrrole nanowires based biosensor [J].
Thi Luyen Tran ;
Thi Xuan Chu ;
Dang Chinh Huynh ;
Duc Thanh Pham ;
Thi Hoai Thuong Luu ;
Anh Tuan Mai .
APPLIED SURFACE SCIENCE, 2014, 314 :260-265
[48]   Kinetics of Redox Processes in the Polymer Films of Ni(II) Salen Type Complexes [J].
Tomczyk, Danuta ;
Bukowski, Wiktor ;
Bester, Karol .
JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2019, 166 (06) :H194-H204
[49]   Haemotoxicity of chloramphenicol succinate in the CD-1 mouse and Wistar Hanover rat [J].
Turton, JA ;
Yallop, D ;
Andrews, CM ;
Fagg, R ;
York, M ;
Williams, TC .
HUMAN & EXPERIMENTAL TOXICOLOGY, 1999, 18 (09) :566-576
[50]  
Vu V., 2019, VIETNAM J CHEM, V57, P328