Optimization of 3D contrast-enhanced pulmonary magnetic resonance angiography in pediatric patients with congenital heart disease

被引:10
作者
Macgowan, CK
Al-Kwifi, O
Varodayan, F
Yoo, SJ
Wright, GA
Kellenberger, CJ
机构
[1] Univ Toronto, Dept Med Imaging, Toronto, ON, Canada
[2] Univ Toronto, Dept Med Biophys, Toronto, ON, Canada
[3] Univ Toronto, Dept Paediat, Toronto, ON M5S 1A1, Canada
关键词
magnetic resonance angiography; pulmonary angiography; congenital heart disease; real-time MRI; artifact;
D O I
10.1002/mrm.20538
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Contrast kinetics were studied in the main pulmonary artery (MIPA) and ascending aorta (AAo) of 12 children with congenital heart disease. This information was used to optimize the timing of data acquisition for contrast-enhanced MR angiography in these vessels. To reduce contrast-agent dosage in these fragile patients, contrast enhancement was measured during routine diagnostic 313 magnetic resonance (MR) angiography instead of using test-bolus methods. This was possible by acquiring 2D cross-sectional images of the MIPA and AAo during the 3D scan. Time-to-peak in the MPA and AAo was 4.9 +/- 2.2 and 6.1 +/- 2.2 s, respectively, while the transit time between the two vessels was 4.5 +/- 0.6 s. A point-spread-function analysis showed that intravascular signal strength was maximized if data acquisition began 4.7 +/- 2.3 s after the first arrival of contrast in the MPA and 5.6 +/- 2.3 s in the AAo. Little signal loss and artifact resulted when longer acquisition delays were used because contrastagent clearance was slow. Based on these results, MR angiography of both the MPA and the AAo in children with congenital heart disease can be performed using elliptic-centric k-space sampling and a trigger delay of 7.9 s after contrast arrival in the AAo (i.e., time-to-peak signal strength in the AAo plus one SD to account for intersubject variability). (c) 2005 Wiley-Liss, Inc.
引用
收藏
页码:207 / 212
页数:6
相关论文
共 15 条
  • [1] Embedded MR fluoroscopy: High temporal resolution real-time imaging during high spatial resolution 3D MRA acquisition
    Fain, SB
    Riederer, SJ
    Huston, J
    King, BF
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2001, 46 (04) : 690 - 698
  • [2] Intracranial arteriovenous malformations: Real-time auto-triggered elliptic centric-ordered 3D gadolinium-enhanced MR angiography - Initial assessment
    Farb, RI
    McGregor, C
    Kim, JK
    Laliberte, M
    Derbyshire, JA
    Willinsky, RA
    Cooper, PW
    Westman, DG
    Cheung, G
    Schwartz, ML
    Stainsby, JA
    Wright, GA
    [J]. RADIOLOGY, 2001, 220 (01) : 244 - 251
  • [3] Analysis of cardiopulmonary transit times at contrast material-enhanced MR imaging in patients with heart disease
    François, CJ
    Shors, SM
    Bonow, RO
    Finn, JP
    [J]. RADIOLOGY, 2003, 227 (02) : 447 - 452
  • [4] Dynamic imaging of intracranial lesions using fast spin-echo imaging: Differentiation of brain tumors and treatment effects
    Hazle, JD
    Jackson, EF
    Schomer, DF
    Leeds, NE
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1997, 7 (06): : 1084 - 1093
  • [5] QUANTITATIVE RADIONUCLIDE ANGIOCARDIOGRAPHY FOR DETERMINATION OF CHAMBER TO CHAMBER CARDIAC TRANSIT TIMES
    JONES, RH
    BATES, BB
    ANDERSON, PA
    SABISTON, DC
    GOODRICH, JK
    MORRIS, JJ
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1972, 30 (08) : 855 - &
  • [6] Test bolus examination in the carotid artery at dynamic gadolinium-enhanced MR angiography
    Kim, JK
    Farb, RI
    Wright, GA
    [J]. RADIOLOGY, 1998, 206 (01) : 283 - 289
  • [7] Phase-encode reordering to minimize errors caused by motion
    Macgowan, CK
    Wood, ML
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1996, 35 (03) : 391 - 398
  • [8] The effects of time varying intravascular signal intensity and k-space acquisition order on three-dimensional MR angiography image quality
    Maki, JH
    Prince, MR
    Londy, FJ
    Chenevert, TL
    [J]. JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (04): : 642 - 651
  • [9] Masui T, 2000, J MAGN RESON IMAGING, V12, P1034, DOI 10.1002/1522-2586(200012)12:6<1034::AID-JMRI32>3.3.CO
  • [10] 2-1