Template-based method to measure the 3D joint space for hand arthritis

被引:0
|
作者
Duryea, J [1 ]
机构
[1] Harvard Univ, Sch Med, Brigham & Womens Hosp, Boston, MA 02115 USA
来源
MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2 | 2005年 / 5745卷
关键词
arthritis; hand; 3D; joint space; computer; template; tomosynthesis; radiography;
D O I
10.1117/12.595717
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
PURPOSE: Rheumatiod arthritis (RA) of the hand is a widespread and debilitating disease with a large social and economic impact. RA damages the inter articular cartilage, causing narrowing of the joint space width (JSW.) In this study a template-based approach for measuring the 3D JSW is presented, which uses multiple projections of the joint and a comparison to 3D templates from anatomical specimens. METHODS: This study examined 20 proximal interphalangeal (PIP), and 20 metacarpophalangeal (MCP) joints. Realistic simulated radiographs with a pitch of 0.1 mm were produced from 3D data sets obtained by imaging skeletal specimens with a 0.066 trim pitch mu CT system. The technique attempted to match each bone to an anatomical template after the template had undergone transformations in virtual imaging space. For each native joint projection, the two opposing margins were delineated using a technique developed to segment bone margins on hand radiographs. The projected margins of each joint surface at each acquisition were then compared to a set of margins created by projecting rays through the surfaces of the anatomical templates, and the best-matched template was chosen. The performance was evaluated by calculating dJSW = vertical bar Native joint JSW- Template JSW vertical bar. RESULTS: The average dJSW ranged from 0.10 mm to 0.30 mm for approximately half of the average joint radius. CONCLUSIONS: A new technique for 3D imaging based on anatomical templates has been demonstrated. The work is specific to hand imaging but may be applied to other anatomical objects with regularity of shape. It may also complement previous work in digital tomosynthesis.
引用
收藏
页码:781 / 790
页数:10
相关论文
共 50 条
  • [31] 3D MRI of the Hand and Wrist: Technical Considerations and Clinical Applications
    Dalili, Danoob
    Fritz, Jan
    Isaac, Amanda
    SEMINARS IN MUSCULOSKELETAL RADIOLOGY, 2021, 25 (03) : 501 - 513
  • [32] Correlation of 3D Joint Space Width From Weightbearing CT With Outcomes After Intra-articular Calcaneal Fracture
    Day, Molly A.
    Ho, Michael
    Dibbern, Kevin
    Rao, Karan
    An, Qiang
    Anderson, Donald D.
    Marsh, J. Lawrence
    FOOT & ANKLE INTERNATIONAL, 2020, 41 (09) : 1106 - 1116
  • [33] Testing of a 3D printed hand exoskeleton for an individual with stroke: a case study
    Dudley, Drew R.
    Knarr, Brian A.
    Siu, Ka-Chun
    Peck, Jean
    Ricks, Brian
    Zuniga, Jorge M.
    DISABILITY AND REHABILITATION-ASSISTIVE TECHNOLOGY, 2021, 16 (02) : 209 - 213
  • [34] A new method for 3D reconstruction in digital tomosynthesis
    Claus, BEH
    Eberhard, JW
    MEDICAL IMAGING 2002: IMAGE PROCESSING, VOL 1-3, 2002, 4684 : 814 - 824
  • [35] Identification of Defects in 3D Space Using Computer Radiography System
    Chlewicki, Wojciech
    Baniukiewicz, Piotr
    Chady, Tomasz
    Brykalski, Andrzej
    ELECTROMAGNETIC NONDESTRUCTIVE EVALUATION (XIV), 2011, 35 : 30 - 35
  • [36] The Challenges in Modeling Human Performance in 3D Space with Fitts' Law
    Triantafyllidis, Eleftherios
    Li, Zhibin
    EXTENDED ABSTRACTS OF THE 2021 CHI CONFERENCE ON HUMAN FACTORS IN COMPUTING SYSTEMS (CHI'21), 2021,
  • [37] Clinical study of 3D printing template in the treatment of pediatric distal tibial epiphyseal fracture
    Taotao Hui
    Jun Wang
    Yinghao Yu
    Li Qiang
    Haojuan Dong
    Weifeng Lin
    BMC Musculoskeletal Disorders, 26 (1)
  • [38] C3N4 Template-Based N-Doped Porous Carbon Cathode for Zinc-Ion Hybrid Capacitors
    Cao, Zhen
    Zhang, Weijie
    Li, Yuying
    Qu, Junnan
    Ren, Jingxuan
    Zhang, Yinghua
    Chen, Jinhao
    Lei, Jiahao
    Li, Jingyao
    Guo, Xinli
    ACS APPLIED NANO MATERIALS, 2024, 7 (21) : 24778 - 24787
  • [39] Design and application of a novel 3D printing digital navigation template for cubitus varus deformity in children
    Zou, Ming
    He, Youzhi
    Xu, Yuxia
    Shi, Qiang
    Zeng, Hao
    FRONTIERS IN PEDIATRICS, 2024, 12
  • [40] A non-template hydrothermal route to uniform 3D macroporous films with switchable optical properties
    Liu, Yong
    Wang, Hai
    Wang, Yong-cai
    Zhao, Wen-xia
    Huang, Hong
    Liang, Chao-lun
    Shen, Hui
    JOURNAL OF NON-CRYSTALLINE SOLIDS, 2011, 357 (07) : 1768 - 1773