Differences in continuous spectra of fractionated electrograms in paroxysmal versus persistent atrial fibrillation

被引:3
作者
Ciaccio, Edward J. [1 ]
Biviano, Angelo B. [1 ]
Iyer, Vivek [1 ]
Garan, Hasan [1 ]
机构
[1] Columbia Univ, Dept Med, Div Cardiol, New York, NY USA
关键词
Atrial fibrillation; Dominant frequency; Paroxysmal; Persistent; Power spectrum; INTACT HUMAN HEART; SPATIAL-ORGANIZATION; DOMINANT FREQUENCY; ABLATION; ACTIVATION; TRANSFORM; PATTERNS;
D O I
10.1016/j.compbiomed.2016.06.021
中图分类号
Q [生物科学];
学科分类号
07 ; 0710 ; 09 ;
摘要
Introduction: Quantitative measurements are helpful to discern fractionated electrograms in paroxysmal and persistent atrial fibrillation (AF), and may be useful to detect optimal ablation sites. However, electrical activation events can be transient, leading to erroneous estimates of electrogram properties. Measurement of continuous changes in electrogram frequency content may improve analysis. Method: Fractionated local electrograms from 10 paroxysmal and 10 persistent AF patients were acquired from outside the pulmonary vein ostia and left atrial free wall using the distal bipolar ablation catheter electrode, and analyzed over continuous 16 second intervals. A New Spectral Estimator (NSE) updated the frequency spectrum and spectral parameters once per millisecond. The tallest spectral peak (dominant frequency or DF) was determined. Statistical tests of variability were used to determine significant differences between paroxysmal and persistent AF. Results: Changes in the value of the DF over 16 seconds were caused by transient drifts in the frequency of the dominant peak, or by changes in which peak had the highest amplitude. The continuous DF and the spectral profile parameters were more highly variable in paroxysmal as compared with persistent AF patients (p < 0.001). There was found to be a gradient from high to low variability of DF in paroxysmal AF, from the left superior pulmonary vein antrum to the left atrial free wall. Conclusions: The results suggest that atrial electrical activation becomes more stable and focused at a narrow frequency range in persistent as compared to paroxysmal AF. The NSE implemented for continuous update of spectral parameters, enables a rapid characterization of fractionated electrograms with high time-frequency resolution and low computational cost. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:50 / 59
页数:10
相关论文
共 18 条
  • [1] Quantitative assessment of the spatial organization of atrial fibrillation in the intact human heart
    Botteron, GW
    Smith, JM
    [J]. CIRCULATION, 1996, 93 (03) : 513 - 518
  • [2] A TECHNIQUE FOR MEASUREMENT OF THE EXTENT OF SPATIAL-ORGANIZATION OF ATRIAL ACTIVATION DURING ATRIAL-FIBRILLATION IN THE INTACT HUMAN HEART
    BOTTERON, GW
    SMITH, JM
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1995, 42 (06) : 579 - 586
  • [3] Software algorithm and hardware design for real-time implementation of new spectral estimator
    Ciaccio, Edward J.
    Biviano, Angelo B.
    Garan, Hasan
    [J]. BIOMEDICAL ENGINEERING ONLINE, 2014, 13
  • [4] The dominant morphology of fractionated atrial electrograms has greater temporal stability in persistent as compared with paroxysmal atrial fibrillation
    Ciaccio, Edward J.
    Biviano, Angelo B.
    Garan, Hasan
    [J]. COMPUTERS IN BIOLOGY AND MEDICINE, 2013, 43 (12) : 2127 - 2135
  • [5] Spectral Profiles of Complex Fractionated Atrial Electrograms Are Different in Longstanding and Acute Onset Atrial Fibrillation Atrial Electrogram Spectra
    Ciaccio, Edward J.
    Biviano, Angelo B.
    Whang, William
    Gambhir, Alok
    Garan, Hasan
    [J]. JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2012, 23 (09) : 971 - 979
  • [6] Improved frequency resolution for characterization of complex fractionated atrial electrograms
    Ciaccio, Edward J.
    Biviano, Angelo B.
    Whang, William
    Garan, Hasan
    [J]. BIOMEDICAL ENGINEERING ONLINE, 2012, 11
  • [7] Identification of recurring patterns in fractionated atrial electrograms using new transform coefficients
    Ciaccio, Edward J.
    Biviano, Angelo B.
    Whang, William
    Garan, Hasan
    [J]. BIOMEDICAL ENGINEERING ONLINE, 2012, 11
  • [8] Differences in Repeating Patterns of Complex Fractionated Left Atrial Electrograms in Longstanding Persistent Atrial Fibrillation as Compared With Paroxysmal Atrial Fibrillation
    Ciaccio, Edward J.
    Biviano, Angelo B.
    Whang, William
    Vest, John A.
    Gambhir, Alok
    Einstein, Andrew J.
    Garan, Hasan
    [J]. CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2011, 4 (04) : 470 - 477
  • [9] A new transform for the analysis of complex fractionated atrial electrograms
    Ciaccio, Edward J.
    Biviano, Angelo B.
    Whang, William
    Coromilas, James
    Garan, Hasan
    [J]. BIOMEDICAL ENGINEERING ONLINE, 2011, 10
  • [10] New methods for estimating local electrical activation rate during atrial fibrillation
    Ciaccio, Edward J.
    Biviano, Angelo B.
    Whang, William
    Wit, Andrew L.
    Garan, Hasan
    Coromilas, James
    [J]. HEART RHYTHM, 2009, 6 (01) : 21 - 32