Relationship between Stent Malapposition and Incomplete Neointimal Coverage after Drug-Eluting Stent Implantation

被引:6
作者
Kim, Byeong-Keuk [2 ]
Hong, Myeong-Ki [1 ,2 ]
Shin, Dong-Ho [2 ]
Kim, Jung-Sun [2 ]
Ko, Young-Guk [2 ]
Choi, Donghoon [2 ]
Jang, Yangsoo [2 ]
机构
[1] Yonsei Univ, Div Cardiol, Severance Cardiovasc Ctr, Severance Biomed Sci Inst,Coll Med, Seoul 120752, South Korea
[2] Severance Cardiovasc Hosp, Seoul, South Korea
关键词
OPTICAL COHERENCE TOMOGRAPHY; INTRAVASCULAR ULTRASOUND FINDINGS; TERM-FOLLOW-UP; THROMBOSIS; APPOSITION; PREDICTORS; RISK;
D O I
10.1111/j.1540-8183.2011.00706.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Using optical coherence tomography (OCT), we evaluated the relationship between malapposed and uncovered struts following implantation of drug-eluting stents (DESs). Methods: A total of 271 patients with 306 lesions who underwent DES implantation and follow-up OCT were included in the study. The lesions were grouped based on the presence of malapposition and then by the median value of the percentage of malapposed struts (1.3%) to produce 3 groups: lesions without malapposition (group I, n = 232) and those with percentage of malapposed struts <1.3% (group II, n = 37) or =1.3% (group III, n = 37). Percentages of malapposed and uncovered struts were calculated as percent ratio of malapposed or uncovered to total struts in the defined cross-sections, respectively. We compared percentage of uncovered struts in all analyzable struts and in the residual struts without malapposed segments among the 3 groups. Results: Group III showed a significantly larger percentage of uncovered struts among all the struts (group I, 3.7 +/- 6.4 vs. II, 5.5 +/- 5.6 vs. III, 17.6 +/- 15.9%, P < 0.001) and among residual struts without malapposed segments (3.7 +/- 6.4 vs. 5.2 +/- 5.7 vs. 15.0 +/- 14.4%, respectively, P < 0.001). There was a significant correlation between malapposed and uncovered struts in group III (r = 0.393, P = 0.016), but not in group II (r =-0.007, P = 0.965) among residual struts without malapposed segments. Conclusion: The percentage of uncovered DES struts was quite different depending on the presence and extent of malapposed struts. (J Interven Cardiol 2012;25:270277)
引用
收藏
页码:270 / 277
页数:8
相关论文
共 50 条
  • [21] Impact of incomplete stent apposition on long-term clinical outcome after drug-eluting stent implantation
    Cook, Stephane
    Eshtehardi, Parham
    Kalesan, Bindu
    Raeber, Lorenz
    Wenaweser, Peter
    Togni, Mario
    Moschovitis, Aris
    Vogel, Rolf
    Seiler, Christian
    Eberli, Franz R.
    Luescher, Thomas
    Meier, Bernhard
    Jueni, Peter
    Windecker, Stephan
    EUROPEAN HEART JOURNAL, 2012, 33 (11) : 1334 - 1343
  • [22] Major determinants for the uncovered stent struts on optical coherence tomography after drug-eluting stent implantation
    Kim, Byeong-Keuk
    Kim, Jung-Sun
    Oh, Changmyung
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (04) : 705 - 714
  • [23] Antiplatelet therapy after drug-eluting stent implantation
    Warren, Josephine
    Baber, Usman
    Mehran, Roxana
    JOURNAL OF CARDIOLOGY, 2015, 65 (1-2) : 98 - 104
  • [24] Very late stent malapposition: the apparent legacy of first generation drug-eluting stent technology
    Johnson, Thomas W.
    Kay, I. Patrick
    Ormiston, John A.
    Webster, Mark W. I.
    EUROINTERVENTION, 2010, 6 (02) : 290 - 291
  • [25] Long-term Clinical Outcomes of Drug-Eluting Stent Malapposition
    Lee, Seung-Yul
    Mintz, Gary S.
    Kim, Jung-Sun
    Kim, Byeong-Keuk
    Jang, Yangsoo
    Hong, Myeong-Ki
    KOREAN CIRCULATION JOURNAL, 2020, 50 (10) : 880 - 889
  • [26] Optical coherence tomography-based evaluation of malapposed strut coverage after drug-eluting stent implantation
    Kim, Byeong-Keuk
    Shin, Dong-Ho
    Kim, Jung-Sun
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (08) : 1887 - 1894
  • [27] Evaluation neointimal coverage in patients with coronary artery aneurysm formation after drug-eluting stent implantation by optical coherence tomography
    Tian Feng
    Chen Yundai
    Liu Hongbin
    Chen Lian
    Sun Zhijun
    Guo Jun
    Jin Qinhua
    Zhang Tao
    The International Journal of Cardiovascular Imaging, 2013, 29 : 1677 - 1683
  • [28] Relationship between endothelial vasomotor function and strut coverage after implantation of drug-eluting stent assessed by optical coherence tomography
    Hoyoun Won
    Jung-Sun Kim
    Dong-Ho Shin
    Byeong-Keuk Kim
    Young-Guk Ko
    Donghoon Choi
    Yangsoo Jang
    Myeong-Ki Hong
    The International Journal of Cardiovascular Imaging, 2014, 30 : 263 - 270
  • [29] Relationship between endothelial vasomotor function and strut coverage after implantation of drug-eluting stent assessed by optical coherence tomography
    Won, Hoyoun
    Kim, Jung-Sun
    Shin, Dong-Ho
    Kim, Byeong-Keuk
    Ko, Young-Guk
    Choi, Donghoon
    Jang, Yangsoo
    Hong, Myeong-Ki
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2014, 30 (02) : 263 - 270
  • [30] Impact of Coronary Stent Fracture on Restenotic Neointimal Tissue Characterization After Drug-Eluting Stent Implantation An Integrated Backscatter Intravascular Ultrasound Study
    Uchida, Yasuhiro
    Ichimiya, Satoshi
    Ishii, Hideki
    Oishi, Hideo
    Aoki, Toshijiro
    Miki, Yusuke
    Kawamiya, Toshiki
    Ichimiya, Hitoshi
    Watanabe, Junji
    Kanashiro, Masaaki
    Hayano, Shinji
    Suzuki, Susumu
    Amano, Tetsuya
    Matsubara, Tatsuaki
    Murohara, Toyoaki
    INTERNATIONAL HEART JOURNAL, 2017, 58 (06) : 861 - 867