Neutron Detector Sensitivity Measurements and Their Variation

被引:0
|
作者
McKinny, Kevin S. [1 ]
Anderson, Thomas R. [1 ]
Johnson, Nathan H. [1 ]
机构
[1] GE Energys Reuter Stokes Prod Line, Twinsburg, OH 44087 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Historically Helium-3 based neutron detectors have been utilized for many applications including Radiation Portal Monitors and various Nuclear Safeguard applications. With the reduced amount of Helium-3 available alternative technologies are being evaluated and employed for use in these applications. In this study, the performance of Boron-10 lined proportional counters is evaluated experimentally in gamma-ray fields relevant to these applications. The method used to define and measure neutron sensitivity is evaluated, and effects of the ambient gamma field on the measured sensitivity are studied for a variety of detector configurations. Based on the results of this study, a repeatable method of defining and measuring detector sensitivity is reported, and the change in sensitivity that may be observed by systems integrators after incorporating the detectors into completed systems is assessed.
引用
收藏
页码:533 / 537
页数:5
相关论文
共 50 条
  • [31] A NEW DETECTOR FOR NEUTRON CAPTURE CROSS SECTION MEASUREMENTS
    WEIGMANN, H
    CARRARO, G
    BOCKHOFF, KH
    NUCLEAR INSTRUMENTS & METHODS, 1967, 50 (02): : 265 - &
  • [32] Nickel Foil as Transmutation Detector for Neutron Fluence Measurements
    Klupak, Vit
    Viererbl, Ladislav
    Lahodova, Zdena
    Soltes, Jaroslav
    Tomandl, Ivo
    Kudejova, Petra
    ISRD 15 - INTERNATIONAL SYMPOSIUM ON REACTOR DOSIMETRY, 2016, 106
  • [33] The detector for advanced neutron capture experiments:: A 4π BaF2 detector for neutron capture measurements at LANSCE
    Ullmann, JL
    Agvaanluvsan, U
    Alpizar, A
    Bond, EM
    Bredeweg, TA
    Esch, EI
    Folden, CM
    Greife, U
    Hatarik, R
    Haight, RC
    Hoffman, DC
    Hunt, L
    Kronenberg, A
    O'Donnell, JM
    Reifarth, R
    Rundberg, RS
    Schwantes, JM
    Strottman, DD
    Vieira, DJ
    Wilhelmy, JB
    Wouters, JM
    INTERNATIONAL CONFERENCE ON NUCLEAR DATA FOR SCIENCE AND TECHNOLOGY, PTS 1 AND 2, 2005, 769 : 918 - 923
  • [34] γ-ray measurements and neutron sensitivity in a fusion environment
    Nocente, M.
    Angelone, M.
    Blanchard, P.
    Cazzaniga, C.
    Chugunov, I.
    Croci, G.
    Gin, D.
    Grosso, G.
    Kiptily, V. G.
    Neto, A.
    Olariu, A.
    Olariu, S.
    Pereira, R. C.
    Pillon, M.
    Shevelev, A.
    Sousa, J.
    Syme, D. B.
    Tardocchi, M.
    Gorini, G.
    FUSION FOR NEUTRONS AND SUBCRITICAL NUCLEAR FISSION, 2012, 1442 : 311 - 316
  • [35] Precise calibration of 14.1 MeV neutron sensitivity of scintillator detector
    Institute of Nuclear Science and Technique, Sichuan University, Chengdu 610064, China
    不详
    Hedianzixue Yu Tance Jishue, 2006, 6 (710-712+709):
  • [36] High sensitivity portable neutron detector for fissile materials detection
    Athanasiades, Athanasios
    Shehad, Nader N.
    Sun, Liang
    Lyons, Tom D.
    Martin, Christopher S.
    Bu, Lu
    Lacy, Jeffrey L.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 1009 - 1013
  • [37] Sensitivity of GAGG based scintillation neutron detector with SiPM readout
    Fedorov, A.
    Gurinovich, V
    Guzov, V
    Dosovitskiy, G.
    Korzhik, M.
    Kozhemyakin, V
    Lopatik, A.
    Kozlov, D.
    Mechinsky, V
    Retivov, V
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2020, 52 (10) : 2306 - 2312
  • [38] NEUTRON HODOSCOPE DETECTOR FOR IMPROVED NEUTRON SENSITIVITY AND STATISTICS IN PARTICLE BEAM FUSION EXPERIMENTS
    LEEPER, RJ
    CHANG, J
    MCMURTRY, WM
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1979, 24 (08): : 986 - 986
  • [39] Study of neutron sensitivity for vanadium self-powered neutron detector in nuclear reactors
    Wu, Xiong
    Cai, Li
    Zhang, Xiangju
    Wu, Tingyu
    Jiang, Jieqiong
    AIP ADVANCES, 2023, 13 (12)
  • [40] INFLUENCE OF DIFFERENT DETECTOR PARAMETERS ON THE NEUTRON SENSITIVITY OF OSL DETECTORS
    FELLINGER, J
    HENNIGER, J
    HUBNER, K
    SCHMIDT, P
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1987, 260 (2-3): : 478 - 482