Measurement of the x-ray mass attenuation coefficient of copper using 8.85-20 keV synchrotron radiation

被引:83
|
作者
Chantler, CT [1 ]
Tran, CQ
Barnea, Z
Paterson, D
Cookson, DJ
Balaic, DX
机构
[1] Univ Melbourne, Sch Phys, Parkville, Vic 3010, Australia
[2] Australian Nucl Sci & Technol Org, Menai, NSW 2234, Australia
[3] Argonne Natl Lab, Chem Mat CARS CAT, Argonne, IL 60439 USA
来源
PHYSICAL REVIEW A | 2001年 / 64卷 / 06期
关键词
D O I
10.1103/PhysRevA.64.062506
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
This work presents the x-ray extended range technique for measuring x-ray mass attenuation coefficients. This technique includes the use of multiple foil attenuators at each energy investigated, allowing independent tests of detector linearity and of the harmonic contributions to the monochromated synchrotron beam. Measurements over a wide energy range allow the uncertainty of local foil thickness to be minimized by the calibration of thin sample measurements to those of thick samples. The use of an extended criterion for sample thickness selection allows direct determination of dominant systematics, with an improvement of accuracies compared to previous measurements by up to factors of 20. Resulting accuracies for attenuation coefficients of copper (8.84 to 20 keV) are 0.27-0.5%, with reproducibility of 0.02%. We also extract the imaginary component of the form factor from the data with the same accuracy. Results are compared to theoretical calculations near and away from the absorption edge. The accuracy challenges available theoretical calculations, and observed discrepanicies of 10% between current theory and experiments can now be addressed.
引用
收藏
页数:15
相关论文
共 50 条
  • [21] X-RAY EXPERIMENTS USING SYNCHROTRON RADIATION AT A SOURCE
    EISENBERGER, P
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1975, 20 (01): : 51 - 51
  • [22] SCANNING X-RAY MICROSCOPE USING SYNCHROTRON RADIATION
    HOROWITZ, P
    SCIENCE, 1972, 178 (4061) : 608 - &
  • [23] The X-ray measurements of the supermirror using synchrotron radiation
    Okajima, T
    Ichimaru, S
    Tamura, K
    Haga, K
    Ogasaka, Y
    Takahashi, S
    Fukuda, S
    Kitou, H
    Gotou, A
    Tawara, Y
    Yamashita, K
    Tsusaka, Y
    Takeda, S
    Kunieda, H
    ADVANCES IN X-RAY OPTICS, 2001, 4145 : 53 - 60
  • [24] X-ray diffraction microtomography using synchrotron radiation
    Barroso, RC
    Lopes, RT
    de Jesus, EFO
    Oliveira, LF
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 471 (1-2): : 75 - 79
  • [25] X-RAY TOPOGRAPHY USING SYNCHROTRON-RADIATION
    WIETESKA, K
    ACTA PHYSICA POLONICA A, 1994, 86 (04) : 545 - 552
  • [26] X-ray attenuation coefficient measurement of argentine near absorption edges
    Yi, R. (yrq@sina.com), 1600, Editorial Office of High Power Laser and Particle Beams (26):
  • [27] X-RAY HOLOGRAM OBTAINED BY USING SYNCHROTRON RADIATION
    AOKI, S
    ICHIHARA, Y
    KIKUTA, S
    JAPANESE JOURNAL OF APPLIED PHYSICS, 1972, 11 (12) : 1857 - 1857
  • [28] ON THE DEVELOPMENT OF X-RAY MICROPROBES USING SYNCHROTRON RADIATION
    VIS, RD
    VANLANGEVELDE, F
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1991, 54 (1-3): : 417 - 423
  • [29] A TUNABLE X-RAY MICROPROBE USING SYNCHROTRON RADIATION
    WU, Y
    THOMPSON, AC
    UNDERWOOD, JH
    GIAUQUE, RD
    CHAPMAN, K
    RIVERS, ML
    JONES, KW
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 291 (1-2): : 146 - 151
  • [30] X-ray mass attenuation coefficient of silicon: Theory versus experiment
    Tran, CQ
    Chantler, CT
    Barnea, Z
    PHYSICAL REVIEW LETTERS, 2003, 90 (25) : 257401 - 257401