Measurement of the x-ray mass attenuation coefficient of copper using 8.85-20 keV synchrotron radiation

被引:83
作者
Chantler, CT [1 ]
Tran, CQ
Barnea, Z
Paterson, D
Cookson, DJ
Balaic, DX
机构
[1] Univ Melbourne, Sch Phys, Parkville, Vic 3010, Australia
[2] Australian Nucl Sci & Technol Org, Menai, NSW 2234, Australia
[3] Argonne Natl Lab, Chem Mat CARS CAT, Argonne, IL 60439 USA
来源
PHYSICAL REVIEW A | 2001年 / 64卷 / 06期
关键词
D O I
10.1103/PhysRevA.64.062506
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
This work presents the x-ray extended range technique for measuring x-ray mass attenuation coefficients. This technique includes the use of multiple foil attenuators at each energy investigated, allowing independent tests of detector linearity and of the harmonic contributions to the monochromated synchrotron beam. Measurements over a wide energy range allow the uncertainty of local foil thickness to be minimized by the calibration of thin sample measurements to those of thick samples. The use of an extended criterion for sample thickness selection allows direct determination of dominant systematics, with an improvement of accuracies compared to previous measurements by up to factors of 20. Resulting accuracies for attenuation coefficients of copper (8.84 to 20 keV) are 0.27-0.5%, with reproducibility of 0.02%. We also extract the imaginary component of the form factor from the data with the same accuracy. Results are compared to theoretical calculations near and away from the absorption edge. The accuracy challenges available theoretical calculations, and observed discrepanicies of 10% between current theory and experiments can now be addressed.
引用
收藏
页数:15
相关论文
共 61 条
[11]  
Chantler CT, 2000, X-RAY SPECTROM, V29, P449, DOI [10.1002/1097-4539(200011/12)29:6<449::AID-XRS452>3.3.CO
[12]  
2-I, 10.1002/1097-4539(200011/12)29:6<449::AID-XRS452>3.0.CO
[13]  
2-R]
[15]   THEORETICAL FORM-FACTOR, ATTENUATION AND SCATTERING TABULATION FOR Z=1-92 FROM E=1-10 EV TO E=0.4-1.0 MEV [J].
CHANTLER, CT .
JOURNAL OF PHYSICAL AND CHEMICAL REFERENCE DATA, 1995, 24 (01) :71-591
[16]   Calculation of absolute intensities from X-ray imaging plates [J].
Cookson, DJ .
JOURNAL OF SYNCHROTRON RADIATION, 1998, 5 :1375-1382
[18]   PROBLEMS ASSOCIATED WITH THE MEASUREMENT OF X-RAY ATTENUATION COEFFICIENTS .2. CARBON REPORT ON THE INTERNATIONAL UNION OF CRYSTALLOGRAPHY X-RAY ATTENUATION PROJECT [J].
CREAGH, DC ;
HUBBELL, JH .
ACTA CRYSTALLOGRAPHICA SECTION A, 1990, 46 :402-408
[19]   PROBLEMS ASSOCIATED WITH THE MEASUREMENT OF X-RAY ATTENUATION COEFFICIENTS - SILICON - REPORT ON THE INTERNATIONAL-UNION-OF-CRYSTALLOGRAPHY-X-RAY-ATTENUATION-PROJECT [J].
CREAGH, DC ;
HUBBELL, JH .
ACTA CRYSTALLOGRAPHICA SECTION A, 1987, 43 :102-112
[20]  
CREAGH DC, 1995, INT TABLES CRYSTALLO, VC, P206