Development of a new HPLC method for rapid histamine quantification in fish and fishery products without sample clean-up

被引:12
作者
Kounnoun, Ayoub [1 ]
Louajri, Adnane [1 ]
Cacciola, Francesco [2 ]
El Baaboua, Aicha [1 ]
Mondello, Luigi [3 ,4 ,5 ]
Bougtaib, Hajar [1 ]
Alahlah, Naoual [6 ]
Stitou, Meriem [6 ]
El Maadoudi, Mohamed [6 ]
机构
[1] Abd Al Malek Essaadi Univ, Fac Sci Tetouan, Dept Biol, Lab Appl Biol & Pathol, Tetouan, Morocco
[2] Univ Messina, Dept Biomed Dent Morphol & Funct Imaging Sci, Messina, Italy
[3] Univ Messina, Dept Chem Biol Pharmaceut & Environm Sci, Messina, Italy
[4] Univ Messina, Chromaleont Srl, Dept Chem Biol Pharmaceut & Environm Sci, Messina, Italy
[5] Univ Campus Biomed Rome, Dept Sci & Technol Human & Environm, Rome, Italy
[6] Natl Off Food Safety ONSSA, Reg Anal & Res Lab, Tangier, Morocco
关键词
Histamine; Fish; HPLC-FLD; Pre-column derivatization; Optimization; Validation; ORTHO-PHTHALALDEHYDE; LIQUID-CHROMATOGRAPHY; FLUORESCENCE REACTION; BIOGENIC-AMINES; DERIVATIZATION; DERIVATIVES; VALIDATION; STABILITY; FRESH; ACIDS;
D O I
10.1007/s00217-022-03995-z
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
HPLC methods are among the most studied and validated techniques for the quantification of histamine in fish and fishery products; nonetheless, most of these methods require laborious sample extraction and purification. For this purpose, in the present study, an HPLC-FLD method without any sample clean-up procedure was developed, validated and applied for histamine quantification in various fish samples. Histamine was extracted from fish and fishery products samples with perchloric acid; then a simple precolumn derivatization with o-phthalaldehyde was performed in the presence of the reducing agent 2-mercaptoethanol. Once the derivatization was carried out, the separation was performed with a reverse phase HPLC system. In terms of validation, good linearity and specificity over a concentration range from 12.5 to 200 mg/kg were achieved. Also, convenable precision with relative standard deviations smaller than 5.92%, accuracy ranged from 0.40 to 1.84%, and satisfactory recoveries ranged from 100.44 to 101.84%, were obtained. The detection and the quantification limits were calculated at 2.8 and 4.3 mg/kg, respectively. In addition, the effectiveness of the method was evaluated by the analysis of reference materials, proficiency tests and various type of samples. Moreover, the developed method was found to be simple, rapid, and reliable.
引用
收藏
页码:1679 / 1689
页数:11
相关论文
共 39 条
  • [1] ORTHO-PHTHALALDEHYDE DERIVATIVES OF AMINES FOR HIGH-SPEED LIQUID-CHROMATOGRAPHY ELECTROCHEMISTRY
    ALLISON, LA
    MAYER, GS
    SHOUP, RE
    [J]. ANALYTICAL CHEMISTRY, 1984, 56 (07) : 1089 - 1096
  • [2] European official control of food: Determination of histamine in fish products by a HPLC-UV-DAD method
    Altieri, I.
    Semeraro, A.
    Scalise, F.
    Calderari, I.
    Stacchini, P.
    [J]. FOOD CHEMISTRY, 2016, 211 : 694 - 699
  • [3] [Anonymous], 2010, F03110 AFN NF
  • [4] AOAC, 2005, 97713 AOAC
  • [5] Fluorescent immunoliposomal nanovesicles for rapid multi-well immuno-biosensing of histamine in fish samples
    Bajpai, Vivek K.
    Oh, CheolWoo
    Khan, Imran
    Haldorai, Yuvaraj
    Gandhi, Sonu
    Lee, Hoomin
    Song, Xinjie
    Kim, Myunghee
    Upadhyay, Ashutosh
    Chen, Lei
    Huh, Yun Suk
    Han, Young-Kyu
    Shukla, Shruti
    [J]. CHEMOSPHERE, 2020, 243
  • [6] Biogenic amines in seafood: a review
    Biji, K. B.
    Ravishankar, C. N.
    Venkateswarlu, R.
    Mohan, C. O.
    Gopal, T. K. Srinivasa
    [J]. JOURNAL OF FOOD SCIENCE AND TECHNOLOGY-MYSORE, 2016, 53 (05): : 2210 - 2218
  • [7] Development of a Rapid and Eco-Friendly UHPLC Analytical Method for the Detection of Histamine in Fish Products
    Cicero, Antonello
    Galluzzo, Francesco Giuseppe
    Cammilleri, Gaetano
    Pulvirenti, Andrea
    Giangrosso, Giuseppe
    Macaluso, Andrea
    Vella, Antonio
    Ferrantelli, Vincenzo
    [J]. INTERNATIONAL JOURNAL OF ENVIRONMENTAL RESEARCH AND PUBLIC HEALTH, 2020, 17 (20) : 1 - 11
  • [8] Validation and comparison of analytical methods for the determination of histamine in tuna fish samples
    Cinquina, AL
    Longo, F
    Calì, A
    De Santis, L
    Baccelliere, R
    Cozzani, R
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2004, 1032 (1-2) : 79 - 85
  • [9] THE STABILITY OF THE ORTHO-PHTHALALDEHYDE-2-MERCAPTOETHANOL DERIVATIVES OF AMINO-ACIDS - AN INVESTIGATION USING HIGH-PRESSURE LIQUID-CHROMATOGRAPHY WITH A PRECOLUMN DERIVATIZATION TECHNIQUE
    COOPER, JDH
    OGDEN, G
    MCINTOSH, J
    TURNELL, DC
    [J]. ANALYTICAL BIOCHEMISTRY, 1984, 142 (01) : 98 - 102
  • [10] Determination of amino acids using o-phthalaldehyde-2-mercaptoethanol derivatization - Effect of reaction conditions
    Dorresteijn, RC
    Berwald, LG
    Zomer, G
    deGooijer, CD
    Wieten, G
    Beuvery, EC
    [J]. JOURNAL OF CHROMATOGRAPHY A, 1996, 724 (1-2) : 159 - 167