A solution for co-frequency and low SNR problems in heart rate estimation based on photoplethysmography signals

被引:1
|
作者
Zhao, Jiaqi [1 ]
Chen, Xiang [1 ]
Zhang, Xu [1 ]
Chen, Xun [1 ]
机构
[1] Univ Sci & Technol China, Dept Elect Sci & Technol, Hefei 230027, Anhui, Peoples R China
关键词
PPG; Heart rate tracking; Variational mode decomposition; Wearable healthcare; PROBABILISTIC FUNCTIONS;
D O I
10.1007/s11517-022-02678-x
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In order to realize high-accuracy heart rate (HR) estimation based on photoplethysmography (PPG) under the scenes of low signal-to-noise ratio (SNR) and co-frequency caused by motion artifacts (MAs), this paper presents a novel framework integrating two-stage variational mode decomposition (VMD) denoising method, noise compensation technology, and hidden Markov model (HMM)-based tracking algorithm. The two-stage VMD denoising method is designed to separate the HR signal from MA under low SNR scene. The noise compensation technology is applied to solve the problem of co-frequency. HMM-based HR tracking method is adopted to obtain the global optimization performance of HR estimation. The effectiveness and superiority of the proposed framework in solving problems of low SNR and co-frequency associated with motion artifacts have been verified by the HR estimation experiments carried out on three public high-SNR PPG databases (ISPC, BAMI I, BAMI II) and a self-built low-SNR database (WeData). Compared with the two classical frameworks namely joint sparse spectrum reconstruction (JOSS) and convolutional neural network-long short-term memory network (CNN-LSTM), the proposed framework obtains the lowest HR estimation errors (0.94 beats per minute (BPM) and 1.81 BPM respectively) on both BAMI 2 with the highest SNR (0.40 dB) and WeData with the lowest SNR (- 9.07 dB). For the low-SNR database Wedata, the average absolute error (AAE) decreases by more than 21 BPM. The research result of this study provides a solution for the realization of high-accuracy PPG-based HR estimation in exercise scenarios.
引用
收藏
页码:3419 / 3433
页数:15
相关论文
共 50 条
  • [21] Review on Heart-Rate Estimation from Photoplethysmography and Accelerometer Signals During Physical Exercise
    Periyasamy, Vijitha
    Pramanik, Manojit
    Ghosh, Prasanta Kumar
    JOURNAL OF THE INDIAN INSTITUTE OF SCIENCE, 2017, 97 (03) : 313 - 324
  • [22] A NON-DATA-AIDED FREQUENCY OFFSET ESTIMATION ALGORITHM OF TWO CO-FREQUENCY 16QAM SIGNALS
    Wang, Peiqiang
    Liu, Kai
    PROCEEDINGS OF 2016 INTERNATIONAL CONFERENCE ON AUDIO, LANGUAGE AND IMAGE PROCESSING (ICALIP), 2016, : 525 - 528
  • [23] GRGB rPPG: An Efficient Low-Complexity Remote Photoplethysmography-Based Algorithm for Heart Rate Estimation
    Haugg, Fridolin
    Elgendi, Mohamed
    Menon, Carlo
    BIOENGINEERING-BASEL, 2023, 10 (02):
  • [24] Particle filtering based single-channel blind separation of co-frequency MPSK signals
    Tu Shilong
    Chen Shaohe
    Zheng Hui
    Wan Jian
    2007 INTERNATIONAL SYMPOSIUM ON INTELLIGENT SIGNAL PROCESSING AND COMMUNICATION SYSTEMS, VOLS 1 AND 2, 2007, : 602 - +
  • [25] Coherent DOA Estimation Algorithm with Co-Prime Arrays for Low SNR Signals
    Zhang, Fan
    Cao, Hui
    Wang, Kehao
    SENSORS, 2023, 23 (23)
  • [26] Feasibility Study of Deep Neural Network for Heart Rate Estimation from Wearable Photoplethysmography and Acceleration Signals
    Chung, Heewon
    Ko, Hoon
    Lee, Hooseok
    Lee, Jinseok
    2019 41ST ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2019, : 3633 - 3636
  • [27] Estimation of Heart Rate and Respiratory Rate via Blind Estimation from Smartphone-Based Contact Image Photoplethysmography
    Garcia-Lopez, Rodrigo
    Benitez-Benitez, Javier
    Ulises Campos-Delgado, Daniel
    Reyes, Bersain A.
    VIII LATIN AMERICAN CONFERENCE ON BIOMEDICAL ENGINEERING AND XLII NATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, 2020, 75 : 63 - 70
  • [28] Extraction Algorithm of Co-Frequency Aliased Signals Based on Relaxation Modified Fast Independent Component Analysis
    Li Qiang
    Cao Xiaofang
    Shen Dong
    LASER & OPTOELECTRONICS PROGRESS, 2022, 59 (11)
  • [29] Single-Channel Blind Separation of Co-Frequency MPSK Signals Based on PSP Algorithm with DFSE
    Liu, Xiao-Bei
    Guan, Yong Liang
    Koh, Soo Ngee
    2015 IEEE MILITARY COMMUNICATIONS CONFERENCE (MILCOM 2015), 2015, : 1509 - 1514
  • [30] Towards Photoplethysmography-Based Estimation of Instantaneous Heart Rate During Physical Activity
    Jarchi, Delaram
    Casson, Alexander J.
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2017, 64 (09) : 2042 - 2053