Measures of sensation in neurological conditions: a systematic review

被引:68
作者
Connell, L. A. [1 ]
Tyson, S. F. [2 ]
机构
[1] Univ Nottingham, Div Physiotherapy Educ, Nottingham NG5 1PB, England
[2] Univ Salford, Manchester, Lancs, England
关键词
Sensation; measurement; clinical utility; psychometric; VIBRATORY PERCEPTION THRESHOLD; JOINT-POSITION SENSE; SOMATOSENSORY ASSESSMENT; PSYCHOMETRIC PROPERTIES; TEMPORAL THRESHOLDS; MULTIPLE-SCLEROSIS; CLINICAL UTILITY; RASCH ANALYSIS; STROKE; REHABILITATION;
D O I
10.1177/0269215511412982
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To systematically review the psychometric properties and clinical utility of measures of sensation in neurological conditions to inform future research studies and clinical practice. Data sources: Electronic databases (MEDLINE, CINAHL, EMBASE and AMED) were searched from their inception to December 2010. Review methods: Search terms were used to identify articles that investigated any sensory measures in neurological conditions. Data about their psychometric properties and clinical utility were extracted and analyzed independently. The strength of the psychometric properties and clinical utility were assessed following recommendations. Results: Sixteen sensory measures were identified. Inter-rater reliability and redundancy of testing protocols are particular issues for this area of assessment. Eleven were rejected because they were not available for a researcher or clinician to use. Of the remaining five measures, the Erasmus MC modifications of the Nottingham Sensory Assessment and the Sensory section of the Fugl-Meyer Assessment showed the best balance of clinical utility and psychometric properties. Conclusion: Many measures of sensory impairment have been used in research but few have been fully developed to produce robust data and be easy to use. At present, the sensory section of the Fugl-Meyer Assessment and the Erasmus MC modifications of the Nottingham Sensory Assessment show the most effective balance of usability and robustness, when delivered according to the operating instructions.
引用
收藏
页码:68 / 80
页数:13
相关论文
共 51 条
[1]  
American Occupational Therapy Association, 2010, STAND PRACT OCC THER, P64
[2]  
American Society for Surgery of the Hand, 1978, AM SOC SURG HAND HAN
[3]  
[Anonymous], MULT SCLER NAT CLIN
[4]  
[Anonymous], 2003, BRIT SOC REHABILITAT
[5]  
[Anonymous], 2008, NAT CLIN GUID STROK
[6]  
[Anonymous], COR STAND PHYS PRACT
[7]   Identifying reliable change in tactile temporal thresholds in multiple sclerosis: test-retest reliability [J].
Brown, L. N. ;
Metz, L. M. ;
Eliasziw, M. .
MULTIPLE SCLEROSIS JOURNAL, 2006, 12 (05) :573-577
[8]   Sensory temporal thresholds and interhemispheric transfer times in multiple sclerosis: A preliminary study of a new outcome measure [J].
Brown, LN ;
Metz, LM ;
Sainsbury, RS .
JOURNAL OF CLINICAL AND EXPERIMENTAL NEUROPSYCHOLOGY, 2003, 25 (06) :783-792
[9]  
BURROWS L, 1999, GROSS MOTOR ABILITY
[10]   How many body locations need to be tested when assessing sensation after stroke? An investigation of redundancy in the Rivermead Assessment of Somatosensory Performance [J].
Busse, Monica ;
Tyson, Sarah F. .
CLINICAL REHABILITATION, 2009, 23 (01) :91-95