Study of Islanding Behavior of a Grid-Connected Photovoltaic System Equipped with a Feed-Forward Control Scheme

被引:0
|
作者
Dash, Prajna Paramita [1 ]
Kazerani, Mehrdad [1 ]
机构
[1] Univ Waterloo, Waterloo, ON N2L 3G1, Canada
来源
IECON 2010 - 36TH ANNUAL CONFERENCE ON IEEE INDUSTRIAL ELECTRONICS SOCIETY | 2010年
关键词
PERFORMANCE; INVERTERS; VOLTAGE;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
One of the main issues related to the integration of Distributed Generation (DG) in the utility grid is safety. The protection schemes of distribution systems are usually designed under the assumption that power flows from distribution system to end users. If a fault takes place and a breaker opens, all circuits downstream will be deenergized. However, this is not the case when a DG is used, and it is possible that an Island with power generation and consumption is created, thus raising concerns with respect to equipment and personnel safety. During islanding, a portion of the utility system which contains both load and generation is isolated from the remainder of the system and continues to operate, a condition that is not desirable. Therefore, a DG interfaced with the utility system must be equipped with an anti-islanding scheme to ensure personnel safety and acceptable power quality. Performance of an anti-islanding scheme is usually evaluated by inspecting the corresponding Non Detection Zone (NDZ). It has been reported in past studies that DG's control scheme has an impact on the NDZ. This paper studies the impact of control structure on NDZ is studied in a grid-connected PV system equipped with a feed-forward control scheme.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Stabilization of Grid-Connected Inverter System with Feed-Forward Control
    Kato, Toshiji
    Inoue, Kaoru
    Nakajima, Yusuke
    2017 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2017, : 3375 - 3382
  • [2] Grid-connected control strategy of photovoltaic inverter based on double sequence feed-forward decoupling
    Yang H.
    Song G.
    Teng F.
    Yang Z.
    Chen Y.
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2021, 42 (01): : 77 - 84
  • [3] Implementation of grid-connected photovoltaic system with power factor control and islanding detection
    Mekhilef, S
    Rahim, NA
    PESC 04: 2004 IEEE 35TH ANNUAL POWER ELECTRONICS SPECIALISTS CONFERENCE, VOLS 1-6, CONFERENCE PROCEEDINGS, 2004, : 1409 - 1412
  • [4] Islanding Prevention Scheme for Grid-Connected Photovoltaic Systems in Matlab/Simulink
    Banu, Ioan Viorel
    Istrate, Marcel
    2014 49TH INTERNATIONAL UNIVERSITIES POWER ENGINEERING CONFERENCE (UPEC), 2014,
  • [5] Improved Adaptive Feed-Forward Harmonic Cancellation Technique for Grid Connected Photovoltaic System
    Bhattacharyya, Sudip
    Kumar, Shailendra
    Singh, Bhim
    2018 IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, DRIVES AND ENERGY SYSTEMS (PEDES), 2018,
  • [6] MPPT and anti-islanding of photovoltaic grid-connected system
    Cai, L.-C. (cailicun@xjgc.com), 1600, Power System Protection and Control Press (40):
  • [7] Adaptive Novel Feed-forward Control Strategy for LCL Type Grid-connected Inverters in the Weak Grid
    Cao Z.
    Xiao X.
    Li Y.
    Luo D.
    Wang H.
    Zhou Y.
    Gaodianya Jishu/High Voltage Engineering, 2020, 46 (05): : 1567 - 1576
  • [8] Impact of Feed-forward and Decoupling Terms on Stability of Grid-Connected Inverters
    Silwal, Sushil
    Karimi-Ghartemani, Masoud
    Sharma, Roshan
    Karimi, Houshang
    2019 IEEE 28TH INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE), 2019, : 2641 - 2646
  • [9] Prevention of islanding in grid-connected photovoltaic systems
    Ropp, ME
    Begovic, M
    Rohatgi, P
    PROGRESS IN PHOTOVOLTAICS, 1999, 7 (01): : 39 - 59
  • [10] Study on Photovoltaic Grid-connected Inverter Control System
    Zhang, Hui
    Shan, Lin
    Ren, Jing
    Cheng, Baodan
    Zhang, Hongwei
    2009 INTERNATIONAL CONFERENCE ON POWER ELECTRONICS AND DRIVE SYSTEMS, VOLS 1 AND 2, 2009, : 691 - +