摘要
A new type of chemical sensor for gaseous nitrogen oxides (NOx, the sum of NO and NO2) has been fabricated by combining a porous glass-based NO2 sensing chip with an oxidizing agent. In this device, NO is first oxidized to NO2 over the oxidizer on a porous glass sheet (8 mm square, 1 mm thick) prepared by soaking in a sulfuric acid/potassium permanganate solution, after which the NO2 is detected by a second chip, the same size as the oxidizing chip, impregnated with Saltzman's reagent. A sensor of this type placed in a miniature aluminum holder (3 cm x 5 cm x 1.5 cm) was passively exposed to air containing ppm levels of NO or NO2. As a result, the chip changed from colorless to dark red and a plot of absorbance at 525 nm against the total exposure (defined as the sum of the product of the instantaneous gas concentration by the exposure interval) was linear. Based on the slope of the plot obtained from the NO2 exposure trials, the detection limit of the sensor was approximately 0.2 ppm NO2 assuming a 1 h exposure. It was also found that these devices exhibited equivalent sensitivity to both NO and NO2, indicating that these sensors are capable of measuring the combined NO and NO2 concentration. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:128 / 133
页数:6
相关论文
共 27 条
  • [11] Nanophase separated amphiphilic polymer co-networks as efficient matrices for optical sensors: Rapid and sensitive detection of NO2
    Meskath, Stephan
    Urban, Gerald
    Heinze, Juergen
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2013, 186 : 367 - 373
  • [12] Measurement of nitrogen dioxide and nitrous acid using gas-permeable liquid core waveguides
    Milani, MR
    Dasgupta, PK
    [J]. ANALYTICA CHIMICA ACTA, 2001, 431 (02) : 169 - 180
  • [13] Selective detection of NO by using an amperometric sensor based on stabilized zirconia and oxide electrode
    Miura, N
    Lu, G
    Ono, M
    Yamazoe, N
    [J]. SOLID STATE IONICS, 1999, 117 (3-4) : 283 - 290
  • [14] Miura N., 2008, ADV CHEM SENSORS LAT
  • [15] Electrochemical NOx sensors based on stabilized zirconia: comparison of sensing performances of mixed-potential-type and impedancemetric NOx sensors
    Miura, Norio
    Koga, Tatsuya
    Nakatou, Mitsunobu
    Elumalai, Perumal
    Hasei, Masaharu
    [J]. JOURNAL OF ELECTROCERAMICS, 2006, 17 (2-4) : 979 - 986
  • [16] A review of mixed-potential type zirconia-based gas sensors
    Miura, Norio
    Sato, Tomoaki
    Anggraini, Sri Ayu
    Ikeda, Hiroshi
    Zhuiykov, Serge
    [J]. IONICS, 2014, 20 (07) : 901 - 925
  • [17] Miura N, 2009, SOLID STATE GAS SENSING, P181, DOI 10.1007/978-0-387-09665-0_5
  • [18] Improvement of a monitoring tape for nitrogen dioxide in air
    Nagashima, K
    Nakano, N
    [J]. TALANTA, 1999, 49 (02) : 305 - 308
  • [19] Micro gas analyzers for environmental and medical applications
    Ohira, Shin-Ichi
    Toda, Kei
    [J]. ANALYTICA CHIMICA ACTA, 2008, 619 (02) : 143 - 156
  • [20] A ppb-level NO2 detection system using coloration reactions in porous glass and its humidity dependence
    Ohyama, T
    Maruo, YY
    Tanaka, T
    Hayashi, T
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2000, 64 (1-3) : 142 - 146