Study of the motion artefacts of skin-mounted inertial sensors under different attachment conditions

被引:69
作者
Forner-Cordero, A. [1 ]
Mateu-Arce, M. [2 ]
Forner-Cordero, I. [3 ]
Alcantara, E. [2 ]
Moreno, J. C. [1 ]
Pons, J. L. [1 ]
机构
[1] CSIC, Inst Automat Ind, Bioengn Grp, Madrid 28500, Spain
[2] Inst Biomech Valencia, Valencia, Spain
[3] Univ Hosp La Fe Valencia, Rehabil Dept, Valencia, Spain
关键词
accelerometry; gait; inertial sensing; motion-measurement artifacts;
D O I
10.1088/0967-3334/29/4/N01
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A common problem shared by accelerometers, inertial sensors and any motion measurement method based on skin-mounted sensors is the movement of the soft tissues covering the bones. The aim of this work is to propose a method for the validation of the attachment of skin-mounted sensors. A second-order ( mass -spring -damper) model was proposed to characterize the behaviour of the soft tissue between the bone and the sensor. Three sets of experiments were performed. In the first one, different procedures to excite the system were evaluated to select an adequate excitation stimulus. In the second one, the selected stimulus was applied under varying attachment conditions while the third experiment was used to test the model. The heel drop was chosen as the excitation method because it showed lower variability and could discriminate between different attachment conditions. There was, in agreement with the model, a trend to increase the natural frequency of the system with decreasing accelerometer mass. An important result is the development of a standard procedure to test the bandwidth of skin-mounted inertial sensors, such as accelerometers mounted on the skin or markers heavier than a few grams.
引用
收藏
页码:N21 / N31
页数:11
相关论文
共 24 条
[1]  
Angeloni C., 1994, IEEE Transactions on Rehabilitation Engineering, V2, P40, DOI 10.1109/86.296343
[2]   THE FREQUENCY CONTENT OF GAIT [J].
ANTONSSON, EK ;
MANN, RW .
JOURNAL OF BIOMECHANICS, 1985, 18 (01) :39-47
[3]  
Babin B.J., 1998, Multivariate data analysis, V5th ed.
[4]   Position and orientation in space of bones during movement: Experimental artefacts [J].
Cappozzo, A ;
Catani, F ;
Leardini, A ;
Benedetti, MG ;
DellaCroce, U .
CLINICAL BIOMECHANICS, 1996, 11 (02) :90-100
[5]   Properties of shoe insert materials related to shock wave transmission during gait [J].
Forner, A ;
Garcia, AC ;
Alcantara, E ;
Ramiro, J ;
Hoyos, JV ;
Vera, P .
FOOT & ANKLE INTERNATIONAL, 1995, 16 (12) :778-786
[6]   Inverse dynamics calculations during gait with restricted ground reaction force information from pressure insoles [J].
Forner-Cordero, A ;
Koopman, HJFM ;
van der Helm, FCT .
GAIT & POSTURE, 2006, 23 (02) :189-199
[7]   MEASUREMENT OF THE IMPULSIVE BONE MOTION BY SKIN-MOUNTED ACCELEROMETERS [J].
KIM, W ;
VOLOSHIN, AS ;
JOHNSON, SH ;
SIMKIN, A .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1993, 115 (01) :47-52
[8]   TRANSFER-FUNCTION BETWEEN TIBIAL ACCELERATION AND GROUND REACTION FORCE [J].
LAFORTUNE, MA ;
LAKE, MJ ;
HENNIG, E .
JOURNAL OF BIOMECHANICS, 1995, 28 (01) :113-117
[9]   SKELETAL TRANSIENTS ON HEEL STRIKE IN NORMAL WALKING WITH DIFFERENT FOOTWEAR [J].
LIGHT, LH ;
MCLELLAN, GE ;
KLENERMAN, L .
JOURNAL OF BIOMECHANICS, 1980, 13 (06) :477-480
[10]   Measuring orientation of human body segments using miniature gyroscopes and accelerometers [J].
Luinge, HJ ;
Veltink, PH .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2005, 43 (02) :273-282