Decremental pulmonary venous pulse propagation:: Impact for catheter ablation in focal atrial fibrillation

被引:1
|
作者
Lewalter, T [1 ]
Burkhardt, D [1 ]
Bielik, H [1 ]
Schrickel, J [1 ]
Bitzen, A [1 ]
Shlevkov, N [1 ]
Yang, A [1 ]
Lüdertiz, B [1 ]
Schwab, JO [1 ]
机构
[1] Univ Bonn, Dept Med Cardiol, D-53105 Bonn, Germany
关键词
arrhythmia; atrial fibrillation; catheter ablation; mapping; pulmonary vein;
D O I
10.1023/A:1026248827908
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Electrical isolation of pulmonary veins (PV's) is crucial to achieve success in catheter ablation for trigger elimination in focal atrial fibrillation (AF). To guide ostial PV radiofrequency (RF) delivery, it is necessary to identify the electrical breakthrough (EBT) between PV and left atrium. For this purpose, coronary sinus (CS) fixed rate pacing is commonly used. This study evaluated, whether CS extrastimulus pacing is superior in identifying the EBT area as compared to fixed rate pacing. Methods: In 9 patients (51 +/- 10 years) undergoing a left sided electrophysiological study for AF ablation, 25 PV's (10 right and 15 left-sided PV's) were mapped using a 4 French fixed-wire catheter with eight 6 mm coiled Platinum electrodes in a distal looped configuration (Revelation Helix, Cardima Inc.). For mapping and ablation the electrode loop was positioned in the PV ostium rectangular to the longitudinal PV axis. EBT area was identified as those electrodes indicating the earliest PV signals during CS pacing. We measured number of EBT electrodes and time between EBT and the latest activated bipoles at the electrode loop during fixed rate and extrastimulus pacing. The reduction of two or more EBT electrodes was defined as a significant benefit in EBT identification. Results: In 22 of 25 PV's mapped PV potentials could be observed. Performing fixed rate pacing the EBT area was identified in a mean of 4.2 +/- 1 electrodes, whereas using extrastimulus pacing, EBT area could be significantly reduced to 2.3 +/- 0.8 electrodes. The time between EBT and latest electrode activated increased from 14 +/- 7 ms to 22 +/- 10 ms indicating an intrapulmonary conduction delay during extrastimulus pacing. In 13 of 22 PV's mapped (59%), extrastimulus pacing was beneficial in the identification of the EBT, as the primary target for RF delivery. Conclusions: CS extrastimulus pacing induces intra-PV decremental conduction properties allowing one to identify a more localised and smaller EBT area as the primary target for RF delivery. Performing PV ablation to treat focal AF, extrastimulus maneouvers allow to unmask the "true" EBT and thus may help to limit intrapulmonary RF delivery.
引用
收藏
页码:269 / 273
页数:5
相关论文
共 50 条
  • [1] Decremental Pulmonary Venous Pulse Propagation: Impact for Catheter Ablation in Focal Atrial Fibrillation
    Thorsten Lewalter
    Dietmar Burkhardt
    Helga Bielik
    Jan Schrickel
    Alexander Bitzen
    Nikolai Shlevkov
    Alexander Yang
    Berndt Lüderitz
    Jörg O. Schwab
    Journal of Interventional Cardiac Electrophysiology, 2003, 9 : 269 - 273
  • [2] Decremental intravenous pulse propagation during extrastimulus pacing:: relevance for catheter ablation of focal atrial fibrillation
    Lewalter, T
    Burkhardt, D
    Chun, S
    Schimpf, R
    Bielik, H
    Schrickel, J
    Shlevkov, N
    Yang, A
    Lüderitz, B
    EUROPACE, 2002, 4 (04): : 411 - 415
  • [3] Circumferential pulmonary vein mapping and ablation in focal atrial fibrillation:: Single catheter technique
    Lewalter, T
    Burkhardt, D
    Bielik, H
    Schrickel, J
    Yang, A
    Shlevkov, N
    Schimpf, R
    Schwab, JO
    Lüderitz, B
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2002, 7 (02) : 165 - 170
  • [4] Mew technique for simultaneous catheter mapping of pulmonary veins for catheter ablation in focal atrial fibrillation
    Kumagai, K
    Gondo, N
    Matsumoto, N
    Noguchi, H
    Tojo, H
    Yasuda, T
    Nakashima, H
    Saku, K
    CARDIOLOGY, 2000, 94 (04) : 233 - 238
  • [5] Shnultaneous catheter mapping of the pulmonary veins in focal atrial fibrillation - Significance of rapid focal activation, effectiveness for catheter ablation
    Nakashima, H
    Kumagai, K
    Tojo, H
    Yasuda, T
    Noguchi, H
    Matsumoto, N
    Saku, K
    JAPANESE HEART JOURNAL, 2002, 43 (04): : 357 - 365
  • [6] Case Report: Circumferential Pulmonary Vein Mapping and Ablation in Focal Atrial Fibrillation: Single Catheter Technique
    Thorsten Lewalter
    Dietmar Burkhardt
    Helga Bielik
    Jan Schrickel
    Alexander Yang
    Nikolai Shlevkov
    Rainer Schimpf
    Jörg O. Schwab
    Berndt Lüderitz
    Journal of Interventional Cardiac Electrophysiology, 2002, 7 : 165 - 170
  • [7] Pulmonary vein stenosis complicating catheter ablation of focal atrial fibrillation
    Scanavacca, MI
    Kajita, LJ
    Vieira, M
    Sosa, EA
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2000, 11 (06) : 677 - 681
  • [8] Intravascular pulmonary venous ultrasound imaging for catheter ablation of atrial fibrillation
    Cismaru, Gabriel
    Schiau, Serban
    Muresan, Lucian
    Rosu, Radu
    Puiu, Mihai
    Gusetu, Gabriel
    Pop, Dana
    Zdrenghea, Dumitru
    EXPERT REVIEW OF MEDICAL DEVICES, 2017, 14 (04) : 309 - 314
  • [9] Radiofrequency catheter ablation of focal atrial fibrillation
    Peinado, RP
    Llorens, JLM
    Guindal, JAG
    Daza, JAS
    REVISTA ESPANOLA DE CARDIOLOGIA, 1998, 51 (06): : 494 - 497
  • [10] Efficacy of catheter ablation of focal sources in persistent atrial fibrillation
    Takahashi, Yoshihide
    Yamashita, Syu
    Suzuki, Masahito
    Yabe, Kento
    Hirao, Kenzo
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2018, 29 (04) : 559 - 565