The validity of adenosine triphosphate measurement in detecting endoscope contamination

被引:9
作者
McCafferty, C. E. [1 ,2 ]
Abi-Hanna, D. [3 ,4 ]
Aghajani, M. J. [1 ,2 ]
Micali, G. T. [1 ,2 ]
Lockart, I [3 ]
Vickery, K. [5 ]
Gosbell, I. B. [1 ,2 ]
Jensen, S. O. [1 ,2 ]
机构
[1] Ingham Inst Appl Med Res, Sydney, NSW, Australia
[2] Western Sydney Univ, Sch Med, Sydney, NSW, Australia
[3] Liverpool Hosp, Dept Gastroenterol & Hepatol, Sydney, NSW, Australia
[4] Univ New South Wales, Sch Med, Sydney, NSW, Australia
[5] Macquarie Univ, Australian Sch Adv Med, Sydney, NSW, Australia
关键词
Gastrointestinal endoscopy; Adenosine triphosphate; Endoscope reprocessing; GASTROINTESTINAL ENDOSCOPES; KLEBSIELLA-PNEUMONIAE; DUODENOSCOPES; BIOLUMINESCENCE; DECONTAMINATION; DISINFECTION; TRANSMISSION; UPDATE; RISK;
D O I
10.1016/j.jhin.2018.08.004
中图分类号
R1 [预防医学、卫生学];
学科分类号
1004 ; 120402 ;
摘要
Background: Endoscopic procedures are vital to gastrointestinal disease diagnosis and management, but risk infection transmission. In Australia, endoscopes undergo monthlyto-quarterly microbiological testing, to prevent patient infection. Endoscopes are used more frequently, meaning contamination may not be detected by this surveillance before infection transmission occurs. Aim: To evaluate the use of adenosine triphosphate (ATP) measurement, alongside standard microbiological cultures, in detecting endoscope contamination before high-level disinfection. Using these results, we also aimed to confirm the efficacy of manual cleaning in reducing levels of ATP and cfu/mL. Methods: Seventeen in-clinical-use gastroscopes and 24 in-clinical-use colonoscopes from the Liverpool Hospital Endoscopy unit were sampled across three separate cleaning stages before high-level disinfection. Colony counts and ATP measurements were then performed on these samples. Findings: The correlation between the cfu/mL and RLU of samples collected from colonoscopes was 0.497 (95% confidence interval: 0.28-0.66; P < 0.0001). The correlation between cfu/mL and RLU for samples collected from gastroscopes was 0.377 (0.08-0.61; P = 0.0138). RLU and cfu/mL values were shown to fall significantly (P < 0.005) following precleaning and manual cleaning. Conclusion: There was a significant correlation between ATP and cfu/mL measured from samples collected before high-level disinfection. Precleaning and manual cleaning were shown to reduce ATP and microbiological load significantly. ATP measurement can be performed within minutes with little training and produces results that are easy to interpret. These findings warrant further research on the utility of ATP measurement as a screening tool for detecting endoscope contamination after high-level disinfection. (C) 2018 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:E142 / E145
页数:4
相关论文
共 50 条
  • [21] A differential adenosine triphosphate test method for differentiating between bacterial and fungal contamination in water-miscible metalworking fluids
    Passman, Frederick J.
    Kuenzi, Peter
    INTERNATIONAL BIODETERIORATION & BIODEGRADATION, 2015, 99 : 129 - 137
  • [22] Assessment of postmanual cleaning adenosine triphosphate tests to prevent the use of contaminated duodenoscopes and linear echoendoscopes: the DETECT study
    Rauwers, Arjan W.
    in't Holt, Anne F. Voor
    Buijs, Jolanda G.
    de Groot, Woutrinus
    Erler, Nicole S.
    Vos, Margreet C.
    Bruno, Marco J.
    GASTROINTESTINAL ENDOSCOPY, 2022, 96 (02) : 282 - +
  • [23] Ultrasensitive electrochemiluminescence biosensors based on programmable aptazyme-induced hybridization chain reaction for detecting adenosine triphosphate and quinine
    Liu, Yongmei
    Bian, Huifang
    Wu, Yang
    Yin, Yongde
    Wu, Jiangmin
    Peng, Zhengdong
    Du, Jie
    SENSORS AND ACTUATORS B-CHEMICAL, 2022, 369
  • [24] Preparation of liposome-encapsulating adenosine triphosphate
    Arakawa, A
    Ishiguro, S
    Ohki, K
    Tamai, M
    TOHOKU JOURNAL OF EXPERIMENTAL MEDICINE, 1998, 184 (01) : 39 - 47
  • [25] Adenosine triphosphate bioluminescence to validate decontamination of endoscopes
    Gillespie, E.
    Sievert, W.
    Swan, M.
    Kaye, C.
    Edridge, I.
    Stuart, R. L.
    JOURNAL OF HOSPITAL INFECTION, 2017, 97 (04) : 353 - 356
  • [26] CARDIOPLEGIA WITH ADENOSINE AND ADENOSINE-TRIPHOSPHATE IN THE ISOLATED GUINEA-PIG HEART
    SONCUL, H
    ERSOZ, A
    GOKGOZ, L
    KARASU, C
    AYRANCIOGLU, K
    SINCI, V
    ALTAN, M
    JAPANESE HEART JOURNAL, 1992, 33 (06): : 843 - 850
  • [27] The effect of multiple cycles of contamination, detergent washing, and disinfection on the development of biofilm in endoscope tubing
    Vickery, Karen
    Ngo, Quan-D.
    Zou, Jean
    Cossart, Yvonne E.
    AMERICAN JOURNAL OF INFECTION CONTROL, 2009, 37 (06) : 470 - 475
  • [28] Performance characteristics and optimal cut-off value of triple adenylate nucleotides test versus adenosine triphosphate test as point-of-care testing for predicting inadequacy of duodenoscope reprocessing
    Ridtitid, W.
    Pakvisal, P.
    Chatsuwan, T.
    Kerr, S. J.
    Piyachaturawat, P.
    Luangsukrerk, T.
    Kongkam, P.
    Rerknimitr, R.
    JOURNAL OF HOSPITAL INFECTION, 2020, 106 (02) : 348 - 356
  • [29] Adenosine, adenosine monophosphate, and adenosine triphosphate adsorption from aqueous solutions on the surface of multiwall carbon nanotubes
    M. V. Manilo
    T. A. Alekseeva
    I. A. Ar’ev
    N. I. Lebovka
    Colloid Journal, 2011, 73 : 244 - 247
  • [30] Adenosine, adenosine monophosphate, and adenosine triphosphate adsorption from aqueous solutions on the surface of multiwall carbon nanotubes
    Manilo, M. V.
    Alekseeva, T. A.
    Ar'ev, I. A.
    Lebovka, N. I.
    COLLOID JOURNAL, 2011, 73 (02) : 244 - 247