Far and Near Contrast Sensitivity and Quality of Vision with Six Presbyopia Correcting Intraocular Lenses

被引:11
作者
Gil, Miguel A. [1 ]
Varon, Consuelo [2 ]
Cardona, Genis [2 ]
Buil, Jose A. [1 ]
机构
[1] Santa Creu & St Pau Hosp, Ophthalmol Dept, St Quinti 89, E-08041 Barcelona, Spain
[2] Univ Politecn Cataluna, Dept Opt & Optometry, Violinista Vellsola 37, E-08222 Terrassa, Spain
关键词
cataract surgery; contrast sensitivity; extended depth of focus; multifocal intraocular lens; quality of vision; BILATERAL IMPLANTATION; VISUAL-ACUITY; EXTENDED RANGE; CATARACT-SURGERY; OUTCOMES; DEPTH; FOCUS; PERFORMANCE; DISTANCE; ABERRATION;
D O I
10.3390/jcm11144150
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The objective of this prospective, randomized, double-masked study was to compare the contrast sensitivity and quality of vision of patients bilaterally implanted with the following six different presbyopia correcting intraocular lenses (IOLs): SV25T0 (n = 19), ATLISA 809M (n = 18), ATLISA TRI 839MP (n = 19), ZKB00 (n = 20), ZLB00 (n = 20) and Symfony ZXR00 (n = 20). For comparison purposes, 36 patients were implanted with a monofocal lens (ZA9003). Contrast sensitivity was assessed binocularly at distance under photopic, mesopic and mesopic plus glare conditions, and at near under photopic conditions. Quality of vision was explored in terms of photic phenomena and spectacle independence. Overall, the monofocal lens offered better contrast sensitivity, under all illumination conditions, and less occurrence and intensity of photic phenomena. Amongst the multifocal IOL (MIOL) designs, the extended depth of focus Symfony ZXR00 provided better contrast sensitivity than the other MIOLs, particularly at intermediate and high spatial frequencies. Up to 40% and 50% of patients implanted with MIOLs reported glare and halos, respectively. The SV25T0 resulted in less occurrence and intensity of halos. The evaluation of photic phenomena and contrast sensitivity under different illumination conditions may reflect real-life, visually challenging situations, and thus provide insightful information to assist ophthalmic surgeons when selecting the best intraocular lens for their patients.
引用
收藏
页数:11
相关论文
共 33 条
  • [1] Correlation of pupil size with visual acuity and contrast sensitivity after implantation of an apodized diffractive intraocular lens
    Alfonso, Jose F.
    Fernandez-Vega, Luis
    Baamonde, M. Begona
    Montes-Mico, Robert
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (03) : 430 - 438
  • [2] Visual function comparison of 2 aspheric multifocal intraocular lenses
    Alfonso, Jose F.
    Fernandez-Vega, Luis
    Blazquez, Jose I.
    Montes-Mico, Robert
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (02) : 242 - 248
  • [3] Visual acuity comparison of 2 models of bifocal aspheric intraocular lenses
    Alfonso, Jose F.
    Puchades, Cristina
    Fernandez-Vega, Luis
    Montes-Mico, Robert
    Valcarcel, Beatriz
    Ferrer-Blasco, Teresa
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2009, 35 (04) : 672 - 676
  • [4] One-year outcomes with new-generation multifocal intraocular lenses
    Cillino, Salvatore
    Casuccio, Alessandra
    Di Pace, Francesco
    Morreale, Raffaella
    Pillitteri, Francesco
    Cillino, Giovanni
    Lodato, Gaetano
    [J]. OPHTHALMOLOGY, 2008, 115 (09) : 1508 - 1516
  • [5] Multifocal intraocular lenses in cataract surgery: Literature review of benefits and side effects
    de Vries, Niels E.
    Nuijts, Rudy M. M. A.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2013, 39 (02) : 268 - 278
  • [6] Quality of vision after cataract surgery after Tecnis Z9000 intraocular lens implantation - Effect of contrast sensitivity and wavefront aberration improvements on the quality of daily vision
    Denoyer, Alexandre
    Le Lez, Marie-Laure
    Majzoub, Samuel
    Pisella, Pierre-Jean
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (02) : 210 - 216
  • [7] Through-Focus Vision Performance and Light Disturbances of 3 New Intraocular Lenses for Presbyopia Correction
    Escandon-Garcia, Santiago
    Ribeiro, Filomena J.
    McAlinden, Colm
    Queiros, Antonio
    Gonzalez-Meijome, Jose M.
    [J]. JOURNAL OF OPHTHALMOLOGY, 2018, 2018
  • [8] Visual outcomes after progressive apodized diffractive intraocular lens implantation
    Garcia-Bella, Javier
    Ventura-Abreu, Nestor
    Morales-Fernandez, Laura
    Talavero-Gonzalez, Paula
    Carballo-Alvarez, Jesus
    Carlos Sanz-Fernandez, Juan
    Vazquez-Molini, Jose M.
    Martinez-de-la-Case, Jose M.
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2018, 28 (03) : 282 - 286
  • [9] Visual acuity, contrast sensitivity, subjective quality of vision, and quality of life with 4 different multifocal IOLs
    Gil, Miguel A.
    Varon, Consuelo
    Rosello, Noemi
    Cardona, Genis
    Buil, Jose A.
    [J]. EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2012, 22 (02) : 175 - 187
  • [10] Ginsburg Arthur P., 2003, International Ophthalmology Clinics, V43, P5