Particle Dependence of Quenching Effect in an Optical-Fiber-Type Optically Stimulated Luminescence Dosimeter

被引:20
作者
Hirata, Yuho [1 ]
Watanabe, Kenichi [1 ]
Yoshihashi, Sachiko [1 ]
Uritani, Akira [1 ]
Koba, Yusuke [2 ]
Naruhiro, Matsufuj, I [2 ]
Yanagida, Takayuki [3 ]
Toshito, Toshiyuki [4 ]
Fukuda, Kentaro [5 ]
机构
[1] Nagoya Univ, Grad Sch Engn, Chikusa Ku, Nagoya, Aichi 4648603, Japan
[2] Natl Inst Radiol Sci, Inage Ku, 4-9-1 Anagawa, Chiba, Chiba 2638555, Japan
[3] Nara Inst Sci & Technol, Ikoma, Nara 6300192, Japan
[4] Nagoya Proton Therapy Ctr, Kita Ku, 1-1-1 Hirate, Nagoya, Aichi 4620057, Japan
[5] Tokuyama Corp, 1-1 Mikage, Shunan, Yamaguchi 7458648, Japan
关键词
dosimeter; heavy-ion radiotherapy; optically stimulated luminescence; optical fiber probe; quenching phenomena; PROTON-BEAMS; REAL-TIME; KBR-EU; SCINTILLATION; RADIOTHERAPY; SYSTEM;
D O I
10.18494/SAM.2017.1626
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
To monitor an actual dose in a patient's body during radiotherapy treatment, we have developed a small-size dosimeter of an optical fiber probe mounting optically stimulated luminescence (OSL) materials at the tip. The OSL materials show a quenching effect when they are irradiated by charged particles with high linear energy transfer (LET). We evaluate the particle dependence on the quenching effect in the small-size OSL dosimeter probe. Eu:BaFBr and Ce:CaF2 were adopted as OSL materials, and two types of small-size dosimeter were fabricated. We irradiated 290 MeV/u carbon ions, 150 MeV/u helium ions, and 225 MeV protons and measured the Bragg peak. The Eu:BaFBr small-size dosimeter showed the quenching effect in these three types of particle irradiation. The Ce:CaF2 small-size dosimeter showed the quenching effect only in carbon ion irradiation. The luminescence efficiencies of Eu:BaFBr were compared among these three charged particles. The quenching effect of Eu:BaFBr is independent of the irradiated particles.
引用
收藏
页码:1455 / 1464
页数:10
相关论文
共 19 条
[1]   Characterizing the response of miniature scintillation detectors when irradiated with proton beams [J].
Archambault, Louis ;
Polf, Jerimy C. ;
Beaulieu, Luc ;
Beddar, Sam .
PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (07) :1865-1876
[2]   QUANTIFICATION OF THE RELATIVE BIOLOGICAL EFFECTIVENESS FOR ION BEAM RADIOTHERAPY: DIRECT EXPERIMENTAL COMPARISON OF PROTON AND CARBON ION BEAMS AND A NOVEL APPROACH FOR TREATMENT PLANNING [J].
Elsaesser, Thilo ;
Weyrather, Wilma K. ;
Friedrich, Thomas ;
Durante, Marco ;
Iancu, Gheorghe ;
Kraemer, Michael ;
Kragl, Gabriele ;
Brons, Stephan ;
Winter, Marcus ;
Weber, Klaus-Josef ;
Scholz, Michael .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2010, 78 (04) :1177-1183
[3]   A real-time, high-resolution optical fibre dosemeter based on optically stimulated luminescence (OSL) of KBr:Eu, for potential use during the radiotherapy of cancer [J].
Gaza, R. ;
McKeever, S. W. S. .
RADIATION PROTECTION DOSIMETRY, 2006, 120 (1-4) :14-19
[4]  
Hirata Y., 2016, Journal of Radiation Protection and Research, V41, P228
[5]  
Hirata Y., RAD MEAS IN PRESS
[6]  
Hirata Y., 2016, IONIZING RAD, V41, P157
[7]  
IWABUCHI Y, 1999, FUJI FILM RES DEV, V44, P37
[8]   Optically stimulated luminescence from KBr:Eu as a near-real-time dosimetry system [J].
Klein, D. M. ;
McKeever, S. W. S. .
RADIATION MEASUREMENTS, 2008, 43 (2-6) :883-887
[9]   Performance of a near-real-time KBr:Eu dosimetry system under computed tomography x-rays [J].
Klein, David ;
Peakheart, David W. ;
McKeever, Stephen W. S. .
RADIATION MEASUREMENTS, 2010, 45 (3-6) :663-667
[10]   A simplified scintillator-response formula for multiple-ion energy calibrations [J].
Menchaca-Rocha, A. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 602 (02) :421-424