Conventional Versus Digital Impressions for "All-on-Four" Restorations

被引:84
作者
Gherlone, Enrico [1 ]
Cappare, Paolo [1 ]
Vinci, Raffale [2 ]
Ferrini, Francesco [1 ]
Gastaldi, Giorgio [1 ]
Crespi, Roberto [1 ]
机构
[1] Univ Vita Salute San Raffaele, Dept Dent, IRCCS San Raffaele Hosp, Via Olgettina 48, I-20123 Milan, Italy
[2] Univ Vita Salute San Raffaele, Dept Dent, IRCCS San Raffaele Hosp, Oral Surg Unit, Via Olgettina 48, I-20123 Milan, Italy
关键词
digital impression; immediately loaded implants; tilted implants; ACCURACY; IMPLANTS;
D O I
10.11607/jomi.3900
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: This study aimed to evaluate the most accurate impression technique for "All on Four" restoration, comparing conventional (CIG) and digital impressions (DIG). Materials and Methods: Patients randomly selected for this study were required to be edentulous in at least one arch, presenting with severe posterior mandibular or maxillary atrophy. All patients underwent full-arch immediate-load rehabilitations, which were fixed to a total of four implants (two axial and two tilted). Following implant placement, patients were stratified into two groups. Conventional pick-up was carried out in the control group, and digital impressions were performed in the test group. Following prosthetic rehabilitation, patients underwent intraoral digital radiographs to check for the presence of voids at the bar-implant connection and to evaluate accuracy. Three-, 6-, and 12-month follow-up examinations were performed. Results: A total of 25 patients received immediately loaded "All-on-Four" prostheses (17 maxillary, 13 mandibular) supported by four implants (total 120 implants), of which five received both maxillary and mandibular prosthetic rehabilitation (three patients in CIG, two patients in DIG). No implant dropouts occurred, showing a survival rate of 100%. The digital impression procedure required significantly less time than the conventional procedure (P < .001). Conclusion: Results demonstrate that it is possible to develop computer-aided design/computer-assisted manufacturing (CAD/CAM) cobalt-chromium full-arch rehabilitations with satisfactory accuracy using digital impression techniques.
引用
收藏
页码:324 / 330
页数:7
相关论文
共 22 条
[1]   Impressions are changing Deciding on conventional, digital or digital plus in-office milling [J].
Christensen, Gordon J. .
JOURNAL OF THE AMERICAN DENTAL ASSOCIATION, 2009, 140 (10) :1301-1304
[2]  
Del'Acqua MA, 2008, INT J ORAL MAX IMPL, V23, P226
[3]  
Ender A, 2011, Int J Comput Dent, V14, P11
[4]   A 3 years retrospective study of survival for zirconia-based single crowns fabricated from intraoral digital impressions [J].
Gherlone, Enrico ;
Mandelli, Federico ;
Cappare, Paolo ;
Pantaleo, Giuseppe ;
Traini, Tonino ;
Ferrini, Francesco .
JOURNAL OF DENTISTRY, 2014, 42 (09) :1151-1155
[5]   Digital Impressions for Fabrication of Definitive "All-on-Four" Restorations [J].
Gherlone, Enrico Felice ;
Ferrini, Francesco ;
Crespi, Roberto ;
Gastaldi, Giorgio ;
Cappare, Paolo .
IMPLANT DENTISTRY, 2015, 24 (01) :125-129
[6]  
Henkel Gary L, 2007, Compend Contin Educ Dent, V28, P422
[7]   Digital implant impressions with the "Individualized Scanbody Technique" for emergence profile support [J].
Joda, Tim ;
Wittneben, Julia-Gabriela ;
Braegger, Urs .
CLINICAL ORAL IMPLANTS RESEARCH, 2014, 25 (03) :395-397
[8]   ACCURACY OF 4 TYPES OF RUBBER IMPRESSION MATERIALS COMPARED WITH TIME OF POUR AND A REPEAT POUR OF MODELS [J].
JOHNSON, GH ;
CRAIG, RG .
JOURNAL OF PROSTHETIC DENTISTRY, 1985, 53 (04) :484-490
[9]   Clinical methods for evaluating implant framework fit [J].
Kan, JYK ;
Rungcharassaeng, K ;
Bohsali, K ;
Goodacre, CJ ;
Lang, BR .
JOURNAL OF PROSTHETIC DENTISTRY, 1999, 81 (01) :7-13
[10]  
Karl Matthias, 2005, Implant Dent, V14, P157, DOI 10.1097/01.id.0000163809.37466.ac