A research prototype system for quantum-counting clinical CT

被引:45
作者
Kappler, S. [1 ]
Glasser, F. [2 ]
Janssen, S. [1 ]
Kraft, E. [1 ]
Reinwand, M. [1 ]
机构
[1] Siemens AG, Healthcare Sector, Siemensstr 1, D-91301 Forchheim, Germany
[2] CEA, LETI, MINATEC Grenoble, F-38054 Grenoble, France
来源
MEDICAL IMAGING 2010: PHYSICS OF MEDICAL IMAGING | 2010年 / 7622卷
关键词
CT; CTDE; DET; SYS;
D O I
10.1117/12.844238
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Recent publications emphasize the benefits of quantum-counting applied to the field of Computed Tomography (CT). We present a research prototype scanner with a CdTe-based quantum-counting detector and 20 cm field-of-view (FOV). As of today there is no direct converter material on the market able to operate reliably in the harsh high-flux regime of clinical CT scanners. Nevertheless, we investigate the CT imaging performance that could be expected with high-flux capable material. Therefore we chose pixel sizes of 0.05 mm(2), a good compromise between high-flux counting ability and energy resolution. Every pixel is equipped with two energy threshold counters, enabling contrast-optimization and dual-energy scans. We present a first quantitative analysis of contrast measurements, in which we limit ourselves to a low-flux scenario. Using an Iodine-based contrast agent, we find 17% contrast enhancement at 120 kVp, compared to energy-integrating CT. In addition, the general dual-energy capability was confirmed in first measurements. We conclude our work by demonstrating good agreement of measurement results and detailed CT-system simulations.
引用
收藏
页数:6
相关论文
共 8 条
[1]  
Balda M., 2009, P IEEE MED IM C 2009, VM05, P2588
[2]  
BARBER WC, 2009, P SPIE MED IM C, V7258
[3]  
KAPPLER S, 2009, P SPIE MED IM C, V7258
[4]  
KAPPLER S, 2010, P SPIE MED IM C, V7622
[5]   A Full-System Simulation Chain For Computed Tomography Scanners [J].
Kappler, Steffen ;
Niederloehner, Daniel ;
Wirth, Stefan ;
Stierstorfer, Karl .
2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, :3433-3436
[6]  
Levinson R., 2009, WORKSH PHOT COUNT TE
[7]   Weighted FBP - a simple approximate 3D FBP algorithm for multislice spiral CT with good dose usage for arbitrary pitch [J].
Stierstorfer, K ;
Rauscher, A ;
Boese, J ;
Bruder, H ;
Schaller, S ;
Flohr, T .
PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (11) :2209-2218
[8]   CdZnTe semiconductor detectors for spectroscopic x-ray imaging [J].
Szeles, Csaba ;
Soldner, Stephen A. ;
Vydrin, Steve ;
Graves, Jesse ;
Bale, Derek S. .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (01) :572-582