Residence time distribution study in a pilot-scale liquid phase catalytic exchange (LPCE) column packed with a mixture of hydrophobic and hydrophilic catalysts

被引:6
作者
Goswami, Sunil [1 ]
Shenoy, Niranjan S. [2 ]
Mistry, Krunal A. [2 ]
Gupta, Sulabh [2 ]
Sharma, Vijay K. [1 ]
Bhanja, K. [2 ]
Pant, Harish J. [1 ]
机构
[1] Bhabha Atom Res Ctr, Isotope & Radiat Applicat Div, Mumbai 400085, Maharashtra, India
[2] Bhabha Atom Res Ctr, Heavy Water Div, Mumbai 400085, Maharashtra, India
关键词
Catalytic exchange column; Hydrophobic; Hydrophilic; Mean residence time; Holdup; Axial dispersion exchange with stagnant zone; COUNTER-CURRENT OPERATION; BED REACTOR; FIXED-BED; AXIAL-DISPERSION; TRICKLE FLOW; HOLD-UP; HYDRODYNAMICS; BEHAVIOR; MODEL;
D O I
10.1016/j.apradiso.2021.109840
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Residence time distribution (RTD) measurements were carried out in a packed bed column designed for exchange of hydrogen isotopes. The main objective of the study was to characterize the liquid phase mixing under various processes and operating conditions. The packed bed was composed of a mixture of two different types of catalytic packing materials, i.e., a hydrophobic material and a hydrophilic material. Technitium-99m (99mTc) as sodium pertechnetate was used as a radiotracer for RTD measurements. From the measured RTD curves, mean residence times (MRTs), liquid holdup and degree of mixing of liquid phase were evaluated. An axial dispersion model exchange with stagnant zones was used to simulate the measured RTD curves. The results of model simulation showed that volume fraction of hydrophobic to hydrophilic packing and gas/liquid superficial velocities affect the liquid holdup, bed pressure drop and liquid phase dispersion/mixing characteristics. The results of the present study will help to screen packing, optimize the volume of the packing fractions, design and construct the catalyst and optimize the operating conditions for scale up of the isotope exchange process.
引用
收藏
页数:10
相关论文
共 33 条
[1]   Effect of the flow pattern on catalytic reaction of propylene hydrogenation through structured catalyst bed: Mathematical modeling and experiment observations [J].
Ahmadigoltapeh, S. ;
Mehranbod, N. .
JOURNAL OF NATURAL GAS SCIENCE AND ENGINEERING, 2017, 38 :566-581
[2]   Counter-current operation of structured catalytically packed distillation columns: pressure drop, holdup and mixing [J].
Ellenberger, J ;
Krishna, R .
CHEMICAL ENGINEERING SCIENCE, 1999, 54 (10) :1339-1345
[3]  
Fogler H. S., 1999, ELEMENTS CHEM REACTI
[4]   Hydrodynamic characteristics of mixed catalytic packing for heavy water detritiation [J].
Gheorghe, Ionita ;
Ionut, Spiridon ;
Ciprian, Bucur .
FUSION ENGINEERING AND DESIGN, 2018, 136 :1252-1255
[5]   Hydrodynamic continuum model for gas-liquid fixed beds operating in trickle flow and pre-loading regimes [J].
Iliuta, I ;
Larachi, F ;
Iliuta, MC ;
Grandjean, BPA .
CHEMICAL ENGINEERING RESEARCH & DESIGN, 2002, 80 (A7) :790-798
[6]  
International Atomic Energy Agency, 1984, MAN TRIT NUCL FAC, V234, P18
[7]  
International Atomic Energy Agency, 2010, IAEATECDOC1650
[8]  
International Atomic Energy Agency, 2011, TRAIN COURS SER, V49
[9]  
International Atomic Energy Agency, 2008, TRAIN COURS SER, V31
[10]  
International Atomic Energy Agency, 1996, COMP MAN SER, V11