In Vivo Chemical Monitoring at High Spatiotemporal Resolution Using Microfabricated Sampling Probes and Droplet-Based Microfluidics Coupled to Mass Spectrometry

被引:70
作者
Ngernsutivorakul, Thitaphat [1 ]
Steyer, Daniel J. [1 ]
Valenta, Alec C. [1 ]
Kennedy, Robert T. [1 ,2 ]
机构
[1] Univ Michigan, Dept Chem, 930 N Univ Ave, Ann Arbor, MI 48109 USA
[2] Univ Michigan, Dept Pharmacol, 1150 W Med Ctr Dr, Ann Arbor, MI 48109 USA
关键词
HIGH TEMPORAL RESOLUTION; CAPILLARY LIQUID-CHROMATOGRAPHY; EXTRACELLULAR GLUTAMATE; CEREBROSPINAL-FLUID; RAT STRIATUM; AMINO-ACIDS; ACETYLCHOLINE-RELEASE; BRAIN MICRODIALYSIS; SEGMENTED FLOW; ELECTROPHORESIS;
D O I
10.1021/acs.analchem.8b02468
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An essential approach for in vivo chemical monitoring is to use sampling probes coupled with analytical methods; however, this method traditionally has limited spatial and temporal resolution. To address this problem, we developed an analytical system that combines microfabricated push pull sampling probes with droplet-based microfluidics. The micro fabricated probe provides spatial resolution approximately 1000-fold better than that of common microdialysis probes. Microfabrication also facilitated integration of an extra channel into the probe for microinjection. We created microfluidic devices and interfaces that allowed manipulation of nanoliter droplet samples collected from the microfabricated probe at intervals of a few seconds. Use of droplet-based microfluidics prevented broadening of collected zones, yielding 6 s temporal resolution at 100 nL/min perfusion rates. Resulting droplets were analyzed by direct infusion nanoelectrospray ionization (nESI) mass spectrometry for simultaneous determination of glutamine, glutamate, gamma-aminobutyric acid, and acetylcholine. Use of low infusion rates that enabled nESI (50 nL/min) was critical to allowing detection in the complex samples. Addition of C-13-labeled internal standards to the droplet samples was used for improved quantification. Utility of the overall system was demonstrated by monitoring dynamic chemical changes evoked by microinjection of high potassium concentrations into the brain of live rats. The results showed stimulated neurochemical release with rise times of 15 s. This work demonstrates the potential of coupling microfabricated sampling probes to droplet-based mass spectrometric assays for studying chemical dynamics in a complex microenvironment at high spatiotemporal resolution.
引用
收藏
页码:10943 / 10950
页数:8
相关论文
共 77 条
[1]   Molecular imaging with PET [J].
Ametamey, Simon M. ;
Honer, Michael ;
Schubiger, Pius August .
CHEMICAL REVIEWS, 2008, 108 (05) :1501-1516
[2]   EFFECT OF OPIOIDS ON ACETYLCHOLINE-RELEASE EVOKED BY K+ OR GLUTAMIC-ACID FROM RAT NEOSTRIATAL SLICES [J].
ARENAS, E ;
ALBERCH, J ;
ARROYOS, RS ;
MARSAL, J .
BRAIN RESEARCH, 1990, 523 (01) :51-56
[3]   Fitting Linear Mixed-Effects Models Using lme4 [J].
Bates, Douglas ;
Maechler, Martin ;
Bolker, Benjamin M. ;
Walker, Steven C. .
JOURNAL OF STATISTICAL SOFTWARE, 2015, 67 (01) :1-48
[4]   Human hypocretin and melanin-concentrating hormone levels are linked to emotion and social interaction [J].
Blouin, Ashley M. ;
Fried, Itzhak ;
Wilson, Charles L. ;
Staba, Richard J. ;
Behnke, Eric J. ;
Lam, Hoa A. ;
Maidment, Nigel T. ;
Karlsson, Karl A. E. ;
Lapierre, Jennifer L. ;
Siegel, Jerome M. .
NATURE COMMUNICATIONS, 2013, 4
[5]   Protein adsorption to hydrocephalus shunt catheters: CSF protein adsorption [J].
Brydon, HL ;
Keir, G ;
Thompson, EJ ;
Bayston, R ;
Hayward, R ;
Harkness, W .
JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1998, 64 (05) :643-647
[6]   PHYSICAL-PROPERTIES OF CEREBROSPINAL-FLUID OF RELEVANCE TO SHUNT FUNCTION .1. THE EFFECT OF PROTEIN UPON CSF VISCOSITY [J].
BRYDON, HL ;
HAYWARD, R ;
HARKNESS, W ;
BAYSTON, R .
BRITISH JOURNAL OF NEUROSURGERY, 1995, 9 (05) :639-644
[7]   Electrochemical Analysis of Neurotransmitters [J].
Bucher, Elizabeth S. ;
Wightman, R. Mark .
ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, VOL 8, 2015, 8 :239-261
[8]   Development of μ-Low-Flow-Push-Pull Perfusion Probes for Ex Vivo Sampling from Mouse Hippocampal Tissue Slices [J].
Cabay, Marissa R. ;
McRay, Alyssa ;
Featherstone, David E. ;
Shippy, Scott A. .
ACS CHEMICAL NEUROSCIENCE, 2018, 9 (02) :252-259
[9]   Microfluidic chip for low-flow push-pull perfusion sampling in vivo with on-line analysis of amino acids [J].
Cellar, NA ;
Burns, ST ;
Meiners, JC ;
Chen, H ;
Kennedy, RT .
ANALYTICAL CHEMISTRY, 2005, 77 (21) :7067-7073
[10]   The chemistrode: A droplet-based microfluidic device for stimulation and recording with high temporal, spatial, and chemical resolution [J].
Chen, Delai ;
Du, Wenbin ;
Liu, Ying ;
Liu, Weishan ;
Kuznetsov, Andrey ;
Mendez, Felipe E. ;
Philipson, Louis H. ;
Ismagilov, Rustem F. .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 2008, 105 (44) :16843-16848