InTone: a novel pelvic floor rehabilitation device for urinary incontinence

被引:13
作者
Guralnick, Michael L. [1 ]
Kelly, Holly [1 ]
Engelke, Heather [1 ]
Koduri, Sumana [1 ]
O'Connor, R. Corey [1 ]
机构
[1] Med Coll Wisconsin, Dept Urol & Obstet & Gynecol, Milwaukee, WI 53226 USA
关键词
Biofeedback; Electrical stimulation; Pelvic floor muscles; Urinary incontinence; RANDOMIZED CONTROLLED-TRIAL; ELECTRICAL-STIMULATION; STRESS-INCONTINENCE; WOMEN; BIOFEEDBACK; EXERCISES;
D O I
10.1007/s00192-014-2476-9
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
InTone(TM) (InControl Medical) is a nonimplanted vaginal device providing biofeedback and electrical stimulation of pelvic floor muscles. The purpose of this study was to assess its efficacy and usability for treating urinary incontinence (UI). Women with UI (stress, urge, mixed) were recruited for this pilot trial. InTone was used 5-6 days a week for 12 weeks. Patients were assessed at baseline and monthly with symptom questionnaires [Urinary Distress Index (UDI6), Incontinence Impact Questionnaire (IIQ7)], bladder diaries. and 24-h pad-weight testing (PWT). Efficacy was assessed by comparing 12-week results to baseline values using chi-square and Wilcoxon rank-sum tests. Usability was assessed with a device-usage log and the System Usability Scale (SUS), which evaluates patients' global impression of usability. Thirty-three women were enrolled; five patients withdrew and were excluded. Median age was 50 years (range 35-69). After 12 weeks of InTone therapy, median UDI6 and IIQ7 scores improved from 50.0 to 29.2 (p < 0.001) and from 42.9 to 14.3 (p < 0.001), respectively. Statistically significant reductions in median PWT (35.5-4.6 g, p < 0.001), median daily pad use (4.0-2.0, p < 0.001), and median daily incontinence frequency (4.3-1.0, p < 0.001) were noted; 68 % of patients achieved a > 50 % reduction in daily pad usage and PWT. Device usability was good, with a median SUS of 86.3 and a median expected use of 107 % (33-140 %). Twelve weeks of InTone usage resulted in significant objective and subjective reductions in UI. Device usability was very good.
引用
收藏
页码:99 / 106
页数:8
相关论文
共 29 条
  • [1] Intravaginal electrical stimulation: a randomized, double-blind study on the treatment of mixed urinary incontinence
    Amaro, JL
    Gameiro, MO
    Kawano, PR
    Padovani, CR
    [J]. ACTA OBSTETRICIA ET GYNECOLOGICA SCANDINAVICA, 2006, 85 (05) : 619 - 622
  • [2] American College of Sports Medicine Position Stand, 1990, MED SCI SPORTS EX, V22
  • [3] [Anonymous], 2001, COCHRANE DB SYST REV, DOI DOI 10.1002/14651858.CD001407
  • [4] Bidmead J., 2002, Neurourology and Urodynamics, V21, P372
  • [5] Pelvic floor muscle training is effective in treatment of female stress urinary incontinence, but how does it work?
    Bo, K
    [J]. INTERNATIONAL UROGYNECOLOGY JOURNAL, 2004, 15 (02) : 76 - 84
  • [6] Pelvic floor muscle strength and response to pelvic floor muscle training for stress urinary incontinence
    Bo, K
    [J]. NEUROUROLOGY AND URODYNAMICS, 2003, 22 (07) : 654 - 658
  • [7] Brooke J, 1996, SUSa Quick and Dirty Usability Scale, DOI DOI 10.1201/9781498710411-35
  • [8] Brooke J, 2013, J USABILITY STUD, V8, P29
  • [9] Transvaginal electrical stimulation for female urinary incontinence
    Brubaker, L
    Benson, JT
    Bent, A
    Clark, A
    Shott, S
    [J]. AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1997, 177 (03) : 536 - 540
  • [10] Behavioral training with and without biofeedback in the treatment of urge incontinence in older women - A Randomized controlled trial
    Burgio, KL
    Goode, PS
    Locher, JL
    Umlauf, MG
    Roth, DL
    Richter, HE
    Varner, RE
    Lloyd, LK
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2002, 288 (18): : 2293 - 2299