Measurement of absolute concentration and viability of CD34+ cells in cord blood and cord blood products using fluorescent beads and cyanine nucleic acid dyes

被引:0
作者
Hübl, W
Iturraspe, J
Martinez, GA
Hutcheson, CE
Roberts, CG
Fisk, DD
Sugrue, MW
Wingard, JR
Braylan, RC
机构
[1] Univ Florida, Coll Med, Dept Pathol, Gainesville, FL USA
[2] LifeS Community Blood Ctr, Gainesville, FL USA
[3] Univ Florida, Coll Med, Dept Med, Gainesville, FL USA
[4] Univ Florida, Shands Hosp, Gainesville, FL USA
来源
CYTOMETRY | 1998年 / 34卷 / 03期
关键词
flow cytometry; hematopoietic stem cells; cord blood; CD34;
D O I
暂无
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Conventional flow cytometric methods for CD34(+) cell counting may he affected by the high number of nucleated red blood cells or nonviable cells in cord blood and its products. We developed a simple Row cytometric no-wash procedure that avoids these shortcomings because it provides absolute CD34(+) cell counts and assesses cell viability, Samples were incubated with phycoerythrin (PE)-labeled anti-CD34 (Becton Dickinson Immunocytometry Systems [BD], San lose, CA) and peridinin chlorophyll protein (PerCP)-labeled anti-CD45 (BD) in bead-containing TRUCOUNT tubes (BD), After red cell lysis with a fixative-free reagent, the impermeant nucleic acid dye YO-PRO-1 (Molecular Probes, Eugene, OR) was added and samples were analyzed on a single-laser FACSCalibur (BD), A comparison with the ProCOUNT progenitor cell assay (BD) in 57 samples revealed excellent correlation of results (r = 0.98, intercept -0.2 cells/mu l, slope 1.01), Precision studies conveyed coefficients of variation of 6.4 and 8.9% at concentrations of 35 and 16 CD34(+) cells/mu l, respectively, In untreated and leukocyte-enriched cord blood 4.5 +/- 3.8% of CD34(+) cells were stained by YO-PRO-1, representing apoptotic or necrotic cells. In post-thawing cryopreserved samples this number increased to 10.4 +/- 5.5%, Isotype controls showed very low blank values of viable cells (0.1 +/- 0.4 cells/mu l, maximum 2.4) and seemed unnecessary. We found no washing-related alteration of results in 35 samples, indicating that the method may also be performed with cell washing, Replacing YO-PRO-1 with TO-PRO-3 facilitated four-color analysis of subpopulations of viable CD34(+) cells on a FACSCalibur equipped with a second (diode) laser, We found the proposed method to be a rapid, efficient, and flexible procedure that improved validity of CD34(+) cell counts. (C) 1998 Wiley-Liss, Inc.
引用
收藏
页码:121 / 127
页数:7
相关论文
共 29 条
[1]   Biologic and phenotypic analysis of early hematopoietic progenitor cells in umbilical cord blood [J].
Almici, C ;
Carlo-Stella, C ;
Wagner, JE ;
Mangoni, L ;
Garau, D ;
Rizzoli, V .
LEUKEMIA, 1997, 11 (12) :2143-2149
[2]  
ANDREWS RG, 1992, BLOOD, V80, P1693
[3]  
Bender J G, 1992, J Hematother, V1, P329, DOI 10.1089/scd.1.1992.1.329
[4]   Placental and/or umbilical cord blood: An alternative source of hematopoietic stem cells for transplantation [J].
Cairo, MS ;
Wagner, JE .
BLOOD, 1997, 90 (12) :4665-4678
[5]  
Chin-Yee I., 1997, Clin. Immunol. Newsl, V17, P21, DOI [10.1016/S0197-1859(97)81348-9, DOI 10.1016/S0197-1859(97)81348-9]
[6]   Quantification of CD34+ cells: comparison of methods [J].
Fritsch, G ;
Printz, D ;
Stimpfl, M ;
Dworzak, MN ;
Witt, V ;
Potschger, U ;
Buchinger, P .
TRANSFUSION, 1997, 37 (08) :775-784
[7]  
Fritsch G, 1996, BONE MARROW TRANSPL, V17, P169
[8]   A FUNCTIONAL COMPARISON OF CD34(+)CD38(-) CELLS IN CORD-BLOOD AND BONE-MARROW [J].
HAO, QL ;
SHAH, AJ ;
THIEMANN, FT ;
SMOGORZEWSKA, EM ;
CROOKS, GM .
BLOOD, 1995, 86 (10) :3745-3753
[9]   YOPRO-1 PERMITS CYTOFLUOROMETRIC ANALYSIS OF PROGRAMMED CELL-DEATH (APOPTOSIS) WITHOUT INTERFERING WITH CELL VIABILITY [J].
IDZIOREK, T ;
ESTAQUIER, J ;
DEBELS, F ;
AMEISEN, JC .
JOURNAL OF IMMUNOLOGICAL METHODS, 1995, 185 (02) :249-258
[10]  
Keeney M, 1998, CYTOMETRY, V34, P61, DOI 10.1002/(SICI)1097-0320(19980415)34:2<61::AID-CYTO1>3.3.CO