Applicability of linear and nonlinear retention-time models for reversed-phase liquid chromatography separations of small molecules, peptides, and intact proteins

被引:26
作者
Tyteca, Eva [1 ]
De Vos, Jelle [1 ]
Vankova, Nikola [1 ,2 ]
Cesla, Petr [2 ]
Desmet, Gert [1 ]
Eeltink, Sebastiaan [1 ]
机构
[1] Vrije Univ Brussel, Dept Chem Engn, Pleinlaan 2, B-1050 Brussels, Belgium
[2] Univ Pardubice, Fac Chem Technol, Dept Analyt Chem, Pardubice, Czech Republic
关键词
Linear solvent strength model; Method development; Neue-Kuss model; Retention-time prediction; Selectivity; SOLVENT-STRENGTH MODEL; GRADIENT-ELUTION; PREDICTION; OPTIMIZATION; PERFORMANCE; STRATEGIES; SELECTION; INSIGHTS; LIMITS;
D O I
10.1002/jssc.201501395
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The applicability and predictive properties of the linear solvent strength model and two non-linear retention-time models, i.e., the quadratic model and the Neue model, were assessed for the separation of small molecules (phenol derivatives), peptides, and intact proteins. Retention-time measurements were conducted in isocratic mode and gradient mode applying different gradient times and elution-strength combinations. The quadratic model provided the most accurate retention-factor predictions for small molecules (average absolute prediction error of 1.5%) and peptides separations (with a prediction error of 2.3%). An advantage of the Neue model is that it can provide accurate predictions based on only three gradient scouting runs, making tedious isocratic retention-time measurements obsolete. For peptides, the use of gradient scouting runs in combination with the Neue model resulted in better prediction errors (<2.2%) compared to the use of isocratic runs. The applicability of the quadratic model is limited due to a complex combination of error and exponential functions. For protein separations, only a small elution window could be applied, which is due to the strong effect of the content of organic modifier on retention. Hence, the linear retention-time behavior of intact proteins is well described by the linear solvent strength model. Prediction errors using gradient scouting runs were significantly lower (2.2%) than when using isocratic scouting runs (3.2%).
引用
收藏
页码:1249 / 1257
页数:9
相关论文
共 46 条
[21]   Study of Conformation Effects on the Retention of Small Peptides in Reversed-Phase Chromatography by Thermodynamic Analysis and Molecular Dynamics Simulation [J].
Tsai, Ching-W ;
Liu, Chih-I ;
Chan, Ying-C ;
Tsai, Hui-H G. ;
Ruaan, Ruoh-C .
JOURNAL OF PHYSICAL CHEMISTRY B, 2010, 114 (35) :11620-11627
[22]   Prediction of the retention of s-triazines in reversed-phase high-performance liquid chromatography under linear gradient-elution conditions [J].
D'Archivio, Angelo Antonio ;
Maggi, Maria Anna ;
Ruggieri, Fabrizio .
JOURNAL OF SEPARATION SCIENCE, 2014, 37 (15) :1930-1936
[23]   High efficiency polyethylene glycol diacrylate monoliths for reversed-phase capillary liquid chromatography of small molecules [J].
Aggarwal, Pankaj ;
Lawson, John S. ;
Tolley, H. Dennis ;
Lee, Milton L. .
JOURNAL OF CHROMATOGRAPHY A, 2014, 1364 :96-106
[24]   Influence of Mobile Phase Gradients on the Retention and Separation of Peptides from a Cytochrome-c Digest by Reversed-Phase Liquid Chromatography [J].
L. A. Riddle ;
G. Guiochon .
Chromatographia, 2006, 64 :1-7
[25]   Influence of mobile phase gradients on the retention and separation of peptides from a cytochrome-c digest by reversed-phase liquid chromatography [J].
Riddle, L. A. ;
Guiochon, G. .
CHROMATOGRAPHIA, 2006, 64 (3-4) :121-127
[26]   High peak capacity separations of peptides in reversed-phase gradient elution liquid chromatography on columns packed with porous shell particles [J].
Marchetti, Nicola ;
Guiochon, Georges .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1176 (1-2) :206-216
[27]   Predictions of peptides' retention times in reversed-phase liquid chromatography as a new supportive tool to improve protein identification in proteomics [J].
Baczek, Tomasz ;
Kaliszan, Roman .
PROTEOMICS, 2009, 9 (04) :835-847
[28]   Properties of the retention time of ionizable analytes in reversed-phase liquid chromatography under organic modifier gradients in different eluent pHs [J].
Zisi, Ch ;
Fasoula, S. ;
Pappa-Louisi, A. ;
Nikitas, P. .
JOURNAL OF CHROMATOGRAPHY A, 2013, 1314 :138-141
[29]   Efficiency of a solvatic sorption model for the prediction of retention times in linear gradient reversed-phase liquid chromatography working with different stationary phases [J].
Vorslova, Svetlana ;
Golushko, Jelena ;
Galushko, Sergey ;
Viksna, Arturs .
PROCEEDINGS OF THE ESTONIAN ACADEMY OF SCIENCES, 2016, 65 (01) :37-49
[30]   Insights into the Retention Mechanism for Small Neutral Compounds on Silica-Based Phenyl Phases in Reversed-Phase Liquid Chromatography [J].
Sanka N. Atapattu ;
Colin F. Poole ;
Mike B. Praseuth .
Chromatographia, 2018, 81 :225-238