Mitigation of Low-Frequency Oscillation in Power Systems through Optimal Design of Power System Stabilizer Employing ALO

被引:16
作者
Bayu, Endeshaw Solomon [1 ]
Khan, Baseem [1 ]
Ali, Zaid M. [2 ,3 ]
Alaas, Zuhair Muhammed [4 ]
Mahela, Om Prakash [5 ]
机构
[1] Hawassa Univ, Dept Elect & Comp Engn, POB 05, Hawassa, Ethiopia
[2] Prince Sattam Bin Abdulaziz Univ, Coll Engn Wadi Addawasir, Wadi Addawasir 11991, Saudi Arabia
[3] Aswan Univ, Fac Engn, Elect Engn Deptartment, Aswan 81542, Egypt
[4] Jazan Univ, Coll Engn, Elect Engn Dept, Jazan 45142, Saudi Arabia
[5] Rajasthan Rajya Vidyut Prasaran Nigam Ltd, Power Syst Planning Div, Jaipur 302005, Rajasthan, India
关键词
low-frequency oscillations; ant lion optimization; power oscillation damper; power system stabilizer;
D O I
10.3390/en15103809
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Low-frequency oscillations are an inevitable phenomenon of a power system. This paper proposes an Ant lion optimization approach to optimize the dual-input power system stabilizer (PSS2B) parameters to enhance the transfer capability of the 400 kV line in the North-West region of the Ethiopian electric network by the damping of low-frequency oscillation. Double-input Power system stabilizers (PSSs) are currently used in power systems to damp out low-frequency oscillations. The gained minimum damping ratio and eigenvalue results of the proposed Ant lion algorithm (ALO) approach are compared with the existing conventional system to get better efficiency at various loading conditions. Additionally, the proposed Ant lion optimization approach requires minimal time to estimate the key parameters of the power oscillation damper (POD). Consequently, the average time taken to optimally size the parameters of the PSS controller was 14.6 s, which is pretty small and indicates real-time implementation of an ALO developed model. The nonlinear equations that represent the system have been linearized and then placed in state-space form in order to study and analyze the dynamic performance of the system by damping out low-frequency oscillation problems. Finally, conventional fixed-gain PSS improves the maximum overshoot by 5.2% and settling time by 51.4%, but the proposed optimally sized PSS employed with the ALO method had improved the maximum overshoot by 16.86% and settling time by 78.7%.
引用
收藏
页数:29
相关论文
共 18 条
[11]   An optimal modal coordination strategy based on modal superposition theory to mitigate low frequency oscillation in FCWG penetrated power systems [J].
Luo, Jianqiang ;
Bu, Siqi ;
Teng, Fei .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2020, 120
[12]   The Ant Lion Optimizer [J].
Mirjalili, Seyedali .
ADVANCES IN ENGINEERING SOFTWARE, 2015, 83 :80-98
[13]   Optimal damping for generalized unified power flow controller equipped single machine infinite bus system for addressing low frequency oscillation [J].
Rahman, Md Maksudur ;
Ahmed, Ashik ;
Galib, Md Mehedi Hassan ;
Moniruzzaman, Md .
ISA TRANSACTIONS, 2021, 116 (116) :97-112
[14]  
Rout K. C., 2010, 2010 International Conference on Industrial Electronics, Control and Robotics (IECR), P175, DOI 10.1109/IECR.2010.5719844
[15]   Mitigating inter-area oscillation of an interconnected power system considering time-varying delay and actuator saturation [J].
Sengupta, Anirban ;
Das, Dushmanta Kumar .
SUSTAINABLE ENERGY GRIDS & NETWORKS, 2021, 27
[16]   Neurogenetic approach for real-time damping of low-frequency oscillations in electric networks [J].
Shahriar, Mohammad Shoaib ;
Shafiullah, Md ;
Rana, Md Juel ;
Ali, Amjad ;
Ahmed, Ashik ;
Rahman, Syed Masiur .
COMPUTERS & ELECTRICAL ENGINEERING, 2020, 83
[17]  
Thu WM., 2018, ENERGY POWER ENG, V10, P333, DOI [10.4236/epe.2018.108021, DOI 10.4236/EPE.2018.108021]
[18]   Analysis of low frequency interactions of DFIG wind turbine systems in series compensated grids [J].
Trevisan, Aramis S. ;
Fecteau, Martin ;
Mendonca, Angelo ;
Gagnon, Richard ;
Mahseredjian, Jean .
ELECTRIC POWER SYSTEMS RESEARCH, 2021, 191