Mitigation of Low-Frequency Oscillation in Power Systems through Optimal Design of Power System Stabilizer Employing ALO

被引:16
作者
Bayu, Endeshaw Solomon [1 ]
Khan, Baseem [1 ]
Ali, Zaid M. [2 ,3 ]
Alaas, Zuhair Muhammed [4 ]
Mahela, Om Prakash [5 ]
机构
[1] Hawassa Univ, Dept Elect & Comp Engn, POB 05, Hawassa, Ethiopia
[2] Prince Sattam Bin Abdulaziz Univ, Coll Engn Wadi Addawasir, Wadi Addawasir 11991, Saudi Arabia
[3] Aswan Univ, Fac Engn, Elect Engn Deptartment, Aswan 81542, Egypt
[4] Jazan Univ, Coll Engn, Elect Engn Dept, Jazan 45142, Saudi Arabia
[5] Rajasthan Rajya Vidyut Prasaran Nigam Ltd, Power Syst Planning Div, Jaipur 302005, Rajasthan, India
关键词
low-frequency oscillations; ant lion optimization; power oscillation damper; power system stabilizer;
D O I
10.3390/en15103809
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Low-frequency oscillations are an inevitable phenomenon of a power system. This paper proposes an Ant lion optimization approach to optimize the dual-input power system stabilizer (PSS2B) parameters to enhance the transfer capability of the 400 kV line in the North-West region of the Ethiopian electric network by the damping of low-frequency oscillation. Double-input Power system stabilizers (PSSs) are currently used in power systems to damp out low-frequency oscillations. The gained minimum damping ratio and eigenvalue results of the proposed Ant lion algorithm (ALO) approach are compared with the existing conventional system to get better efficiency at various loading conditions. Additionally, the proposed Ant lion optimization approach requires minimal time to estimate the key parameters of the power oscillation damper (POD). Consequently, the average time taken to optimally size the parameters of the PSS controller was 14.6 s, which is pretty small and indicates real-time implementation of an ALO developed model. The nonlinear equations that represent the system have been linearized and then placed in state-space form in order to study and analyze the dynamic performance of the system by damping out low-frequency oscillation problems. Finally, conventional fixed-gain PSS improves the maximum overshoot by 5.2% and settling time by 51.4%, but the proposed optimally sized PSS employed with the ALO method had improved the maximum overshoot by 16.86% and settling time by 78.7%.
引用
收藏
页数:29
相关论文
共 18 条
[1]   Optimal multiobjective design of robust power system stabilizers using genetic algorithms [J].
Abdel-Magid, YL ;
Abido, MA .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2003, 18 (03) :1125-1132
[2]  
Ajami A, 2012, INT REV ELECTR ENG-I, V7, P4954
[3]  
Al-Hinai A. S., 2009, 2009 2nd International Conference on Adaptive Science & Technology (ICAST 2009), P117, DOI 10.1109/ICASTECH.2009.5409738
[4]   Design of adaptive wide-area damping controller based on delay scheduling for improving small-signal oscillations [J].
Darabian, M. ;
Bagheri, A. .
INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2021, 133
[5]  
Datta Subir, 2010, 2010 6th International Conference on Electrical & Computer Engineering (ICECE 2010), P294, DOI 10.1109/ICELCE.2010.5700686
[6]   Simultaneous tuning of power system damping controllers using genetic algorithms [J].
do Bomfim, ALB ;
Taranto, GN ;
Falcao, DM .
IEEE TRANSACTIONS ON POWER SYSTEMS, 2000, 15 (01) :163-169
[7]  
Grebe E, 2010, IEEE POW ENER SOC GE
[8]  
Haghshenas M., 2016, INT J MECHATRON ELEC, V6, P2786
[9]   A Coordinated Design of PSSs and UPFC-based Stabilizer Using Genetic Algorithm [J].
Hassan, Lokman H. ;
Moghavvemi, Mahmoud ;
Almurib, Haider A. F. ;
Muttaqi, Kashem M. .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2014, 50 (05) :2957-2966
[10]  
Khodabakhshian A., 2009, 2009 Canadian Conference on Electrical and Computer Engineering (CCECE 2009), P579, DOI 10.1109/CCECE.2009.5090197