The micro-solution electrochemical method to evaluate rebar corrosion in reinforced concrete structures

被引:8
作者
Tian, Yuwan [1 ,2 ]
Dong, Chaofang [1 ]
Cheng, Xuequn [1 ]
Wan, Yingqi [1 ]
Wang, Gui [2 ]
Xiao, Kui [1 ]
Li, Xiaogang [1 ]
机构
[1] Univ Sci & Technol Beijing, Corros & Protect Ctr, Beijing 100083, Peoples R China
[2] Ocean Univ Guangdong, Engn Coll, Zhanjiang 524088, Peoples R China
基金
中国国家自然科学基金;
关键词
Rebar corrosion; Corrosion rate; Micro-solution; Electrochemical technique; Real site; EMBEDDABLE REFERENCE ELECTRODE; STEEL REINFORCEMENT; PORE SOLUTION; ON-SITE; BEHAVIOR; PERFORMANCE; ENVIRONMENT; RESISTANCE; ROUGHNESS; IMPEDANCE;
D O I
10.1016/j.conbuildmat.2017.06.003
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
An electrochemical method by submersing the HRB400 rebar specimen in simulated micro pore solution (47.125 mu L) is proposed to rapidly evaluate the corrosion rate of HRB400 in concrete. The results show that the corrosion rate of HRB400 in micro-solution is about five times lower than that in bulk solution. The reason for this difference is the anodic polarization caused by the higher concentration of dissolved iron ions in micro-solution. There is a small relational dispersed degree of corrosion rate measured by the optimized electrochemical cell in micro-solution and the real site studies. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:607 / 614
页数:8
相关论文
共 44 条
  • [1] Corrosion performance of blended concretes exposed to different aggressive environments
    Aguirre-Guerrero, Ana Maria
    Mejia-de-Gutierrez, Ruby
    Ribeiro Montes-Correia, Maria Joao
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2016, 121 : 704 - 716
  • [2] Novel anticorrosive pigments based on waste material for corrosion protection of reinforced concrete steel
    Ahmed, N. M.
    Mohamed, M. G.
    Mabrouk, M. R.
    ElShami, A. A.
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2015, 98 : 388 - 396
  • [3] Chloride threshold values to depassivate reinforcing bars embedded in a standardized OPC mortar
    Alonso, C
    Andrade, C
    Castellote, M
    Castro, P
    [J]. CEMENT AND CONCRETE RESEARCH, 2000, 30 (07) : 1047 - 1055
  • [4] Corrosion rate monitoring in the laboratory and on-site
    Andrade, C
    Alonso, C
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 1996, 10 (05) : 315 - 328
  • [5] Test methods for on-site corrosion rate measurement of steel reinforcement in concrete by means of the polarization resistance method
    Andrade, C
    Alonso, C
    Gulikers, J
    Polder, R
    Cigna, R
    Vennesland, O
    Salta, M
    Raharinaivo, A
    Elsener, B
    [J]. MATERIALS AND STRUCTURES, 2004, 37 (273) : 623 - 643
  • [6] Corrosion rate evolution in concrete structures exposed to the atmosphere
    Andrade, C
    Alonso, C
    Sarría, J
    [J]. CEMENT & CONCRETE COMPOSITES, 2002, 24 (01) : 55 - 64
  • [7] Bard Allen J., ELECTROCHEMICAL METH, P51
  • [8] ELECTROCHEMICAL STUDIES OF COPPER, COPPER-ALUMINUM AND COPPER-ALUMINUM-SILVER ALLOYS - IMPEDANCE RESULTS IN 0.5M NACL
    BENEDETTI, AV
    SUMODJO, PTA
    NOBE, K
    CABOT, PL
    PROUD, WG
    [J]. ELECTROCHIMICA ACTA, 1995, 40 (16) : 2657 - 2668
  • [9] Corrosion initiation in cracked fibre reinforced concrete: Influence of crack width, fibre type and loading conditions
    Berrocal, Carlos G.
    Lofgren, Ingemar
    Lundgren, Karin
    Tang, Luping
    [J]. CORROSION SCIENCE, 2015, 98 : 128 - 139
  • [10] Bertolini Luca, 2013, CORROSION STEEL CONC, P30