Motion blur invariant for estimating motion parameters of medical ultrasound images

被引:8
作者
Asli, Barmak Honarvar Shakibaei [1 ,2 ]
Zhao, Yifan [1 ]
Erkoyuncu, John Ahmet [1 ]
机构
[1] Cranfield Univ, Sch Aerosp Transport & Mfg, Ctr Life Cycle Engn & Management, Cranfield MK43 0AL, Beds, England
[2] Czech Acad Sci, Inst Informat Theory & Automat, Pod Vodarenskou Vezi 14, Prague 18208 8, Czech Republic
基金
英国工程与自然科学研究理事会;
关键词
RECOGNITION; RECONSTRUCTION; FILTER;
D O I
10.1038/s41598-021-93636-4
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
High-quality medical ultrasound imaging is definitely concerning motion blur, while medical image analysis requires motionless and accurate data acquired by sonographers. The main idea of this paper is to establish some motion blur invariant in both frequency and moment domain to estimate the motion parameters of ultrasound images. We propose a discrete model of point spread function of motion blur convolution based on the Dirac delta function to simplify the analysis of motion invariant in frequency and moment domain. This model paves the way for estimating the motion angle and length in terms of the proposed invariant features. In this research, the performance of the proposed schemes is compared with other state-of-the-art existing methods of image deblurring. The experimental study performs using fetal phantom images and clinical fetal ultrasound images as well as breast scans. Moreover, to validate the accuracy of the proposed experimental framework, we apply two image quality assessment methods as no-reference and full-reference to show the robustness of the proposed algorithms compared to the well-known approaches.
引用
收藏
页数:13
相关论文
共 42 条
[1]  
Abdolghaffar M, 2014, IEEE ENG MED BIO, P5566, DOI 10.1109/EMBC.2014.6944888
[2]   Dataset of breast ultrasound images [J].
Al-Dhabyani, Walid ;
Gomaa, Mohammed ;
Khaled, Hussien ;
Fahmy, Aly .
DATA IN BRIEF, 2020, 28
[3]  
[Anonymous], 2010, Computational Photography (ICCP), 2010 IEEE International Conference on
[4]  
[Anonymous], 1997, Signals Systems
[5]   Ultrasound Image Filtering and Reconstruction Using DCT/IDCT Filter Structure [J].
Asli, Barmak Honarvar Shakibaei ;
Flusser, Jan ;
Zhao, Yifan ;
Erkoyuncu, John Ahmet ;
Krishnan, Kajoli Banerjee ;
Farrokhi, Yasin ;
Roy, Rajkumar .
IEEE ACCESS, 2020, 8 :141342-141357
[6]   Automatic correction of motion artifacts in magnetic resonance images using an entropy focus criterion [J].
Atkinson, D ;
Hill, DLG ;
Stoyle, PNR ;
Summers, PE ;
Keevil, SF .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 1997, 16 (06) :903-910
[7]   Tri-state median filter for image denoising [J].
Chen, T ;
Ma, KK ;
Chen, LH .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1999, 8 (12) :1834-1838
[8]  
Craig I.J., 1986, IPAG
[9]   Spatial variation and inconsistency between estimates of onset of muscle activation from EMG and ultrasound [J].
Dieterich, Angela V. ;
Botter, Alberto ;
Vieira, Taian Martins ;
Peolsson, Anneli ;
Petzke, Frank ;
Davey, Paul ;
Falla, Deborah .
SCIENTIFIC REPORTS, 2017, 7
[10]   Recognition of blurred images by the method of moments [J].
Flusser, J ;
Suk, T ;
Saic, S .
IEEE TRANSACTIONS ON IMAGE PROCESSING, 1996, 5 (03) :533-538