Squeaking in Third- and Fourth-Generation Ceramic-on-Ceramic Total Hip Arthroplasty Meta-Analysis and Systematic Review

被引:79
作者
Stanat, Scott J. C. [1 ]
Capozzi, James D. [2 ]
机构
[1] SUNY Stony Brook, Med Ctr, Dept Orthopaed, Stony Brook, NY 11794 USA
[2] Winthrop Univ Orthoped, Mineola, NY USA
关键词
hip; arthroplasty; ceramic; squeak; meta-analysis; FEMORAL-HEAD; PATIENTS YOUNGER; BEARING; WEAR; REPLACEMENT; PROSTHESIS; REVISION; MINIMUM;
D O I
10.1016/j.arth.2011.04.031
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Postoperative squeaking in ceramic-on-ceramic total hip arthroplasty is a recently emerging phenomenon. We performed a meta-analysis of published data to examine patient and procedural risk factors. Twelve studies (6137 patients, total) were analyzed, with 150 patients (2.4%) complaining of squeaking. The only significant patient risk factor was increasing body mass index (P = .03, n = 2957). There was no significance found with patient age, sex, height, weight, or procedural laterality for squeak incidence. For implant type, the presence of a Stryker Accolade femoral stem (beta-titanium; Stryker Orthopedics, Mahwah, NJ) was significantly found to increase squeak (P < .0001, n = 4654). The presence of a raised metallic lip on the acetabular component was not found to be associated with squeak. Acetabular cup position was also not found to have a significant bearing on the incidence of squeaking.
引用
收藏
页码:445 / 453
页数:9
相关论文
共 48 条
[1]   Revision total hip arthroplasty performed after fracture of a ceramic femoral head - A multicenter survivorship study [J].
Allain, J ;
Roudot-Thoraval, F ;
Delecrin, J ;
Anract, P ;
Migaud, H ;
Goutallier, D .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2003, 85A (05) :825-830
[2]  
[Anonymous], 75 ANN M AM AC ORTH
[3]  
[Anonymous], J BIOMED MAT RES A
[4]   Cementless total hip arthroplasty with alumina bearings in patients younger than fifty with femoral head osteonecrosis [J].
Baek, Seung-Hoon ;
Kim, Shin-Yoon .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (06) :1314-1320
[5]   Ceramic-on-Ceramic Total Hip Arthroplasty: Update [J].
Capello, William N. ;
D'Antonio, James A. ;
Feinberg, Judy R. ;
Manley, Michael T. ;
Naughton, Marybetb .
JOURNAL OF ARTHROPLASTY, 2008, 23 (07) :39-43
[6]   The 2009 Frank Stinchfield Award "Hip Squeaking'' A Biomechanical Study of Ceramic-on-ceramic Bearing Surfaces [J].
Chevillotte, Christophe ;
Trousdale, Robert T. ;
Chen, Qingshan ;
Guyen, Olivier ;
An, Kai-Nan .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2010, 468 (02) :345-350
[7]   How do alternative bearing surfaces influence wear behavior? [J].
Clarke, Ian C. ;
Manley, Michael T. .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2008, 16 :S86-S93
[8]   Alumina ceramic bearings for total hip arthroplasty - Five-year results of a prospective randomized study [J].
D'Antonio, J ;
Capello, W ;
Manley, M ;
Naughton, M ;
Sutton, K .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (436) :164-171
[9]   A titanium-encased alumina ceramic bearing for total hip arthroplasty - 3-to 5-year results [J].
D'Antonio, JA ;
Capello, WN ;
Manley, MT ;
Naughton, M ;
Sutton, K .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (441) :151-158
[10]   METAANALYSIS IN CLINICAL-TRIALS [J].
DERSIMONIAN, R ;
LAIRD, N .
CONTROLLED CLINICAL TRIALS, 1986, 7 (03) :177-188