Clinical Performance of the cobas Liat SARS-CoV-2 & Influenza A/B Assay in Nasal Samples

被引:17
作者
Akashi, Yusaku [1 ,2 ,3 ]
Horie, Michiko [4 ]
Kiyotaki, Junichi [5 ]
Takeuchi, Yuto [1 ,6 ]
Togashi, Kenichi [4 ]
Adachi, Yuki [7 ]
Ueda, Atsuo [8 ]
Notake, Shigeyuki [8 ]
Nakamura, Koji [8 ]
Terada, Norihiko [6 ]
Kurihara, Yoko [6 ]
Kiyasu, Yoshihiko [1 ,6 ]
Suzuki, Hiromichi [3 ,6 ]
机构
[1] Tsukuba Med Ctr Hosp, Div Infect Dis, Dept Med, 1-3-1 Amakubo, Tsukuba, Ibaraki 3058558, Japan
[2] Akashi Clin Internal Med, 3-1-63 Asahigaoka, Osaka 5820026, Japan
[3] Univ Tsukuba, Dept Infect Dis, Fac Med, 1-1-1 Tennodai, Tsukuba, Ibaraki 3058575, Japan
[4] Roche Diagnost KK, Qual & Regulatory, Minato Ku, Shinagawa Season Terrace 1-2-70, Tokyo 1080075, Japan
[5] Miroku Med Lab Inc, 659-2 Innai, Saku, Nagano 3842201, Japan
[6] Univ Tsukuba Hosp, Dept Infect Dis, 2-1-1 Amakubo, Tsukuba, Ibaraki 3058576, Japan
[7] Roche Diagnost KK, Tech Support, Customer Solut, Minato Ku, Shinagawa Season Terrace 1-2-70, Tokyo 1080075, Japan
[8] Tsukuba Med Ctr Hosp, Dept Clin Lab, 1-3-1 Amakubo, Tsukuba, Ibaraki 3058558, Japan
关键词
D O I
10.1007/s40291-022-00580-8
中图分类号
Q3 [遗传学];
学科分类号
071007 ; 090102 ;
摘要
Background and Objective Point-of-care type molecular diagnostic tests have been used for detecting SARS-CoV-2, although their clinical utility with nasal samples has yet to be established. This study evaluated the clinical performance of the cobas Liat SARS-CoV-2 & Influenza A/B (Liat) assay in nasal samples. Methods Nasal and nasopharyngeal samples were collected and were tested using the Liat, the cobas 6800 system and the cobas SARS-CoV-2 & Influenza A/B (cobas), and a method developed by National Institute of Infectious Diseases, Japan (NIID). Results A total of 814 nasal samples were collected. The Liat assay was positive for SARS-CoV-2 in 113 (13.9%). The total, positive, and negative concordance rate between the Liat and cobas/NIID assays were 99.3%/98.4%, 99.1%/100%, and 99.3%/98.2%, respectively. Five samples were positive only using the Liat assay. Their Ct values ranged from 31.9 to 37.2. The Ct values of the Liat assay were significantly lower (p < 0.001) but were correlated (p < 0.001) with those of other molecular assays. In the participants who tested positive for SARS-CoV-2 on the Liat assay using nasopharyngeal samples, 88.2% of their nasal samples also tested positive using the Liat assay. Conclusion The Liat assay showed high concordance with other molecular assays in nasal samples. Some discordance occurred in samples with Ct values > 30 on the Liat assay.
引用
收藏
页码:323 / 331
页数:9
相关论文
共 30 条
[1]   Molecular diagnostic technologies for COVID-19: Limitations and challenges [J].
Afzal, Adeel .
JOURNAL OF ADVANCED RESEARCH, 2020, 26 :149-159
[2]   Analytical and clinical evaluation of a point-of-care molecular diagnostic system and its influenza A/B assay for rapid molecular detection of the influenza virus [J].
Akashi, Yusaku ;
Suzuki, Hiromichi ;
Ueda, Atsuo ;
Hirose, Yumi ;
Hayashi, Daisuke ;
Imai, Hironori ;
Ishikawa, Hiroichi .
JOURNAL OF INFECTION AND CHEMOTHERAPY, 2019, 25 (08) :578-583
[3]  
Centers for Disease Control and Prevention, INT GUID COLL HAND C
[4]   Comparison of Two High-Throughput Reverse Transcription-PCR Systems for the Detection of Severe Acute Respiratory Syndrome Coronavirus 2 [J].
Craney, Arryn R. ;
Velu, Priya D. ;
Satlin, Michael J. ;
Fauntleroy, Kathy A. ;
Callan, Katrina ;
Robertson, Amy ;
La Spina, Marisa ;
Lei, Beryl ;
Chen, Anqi ;
Alston, Tricia ;
Rozman, Anna ;
Loda, Massimo ;
Rennert, Hanna ;
Cushing, Melissa ;
Westblade, Lars F. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2020, 58 (08)
[5]   Clinical evaluation of the BioFire® Respiratory Panel 2.1 and detection of SARS-CoV-2 [J].
Creager, Hannah M. ;
Cabrera, Barbara ;
Schnaubelt, Andy ;
Cox, Jesse L. ;
Cushman-Vokoun, Allison M. ;
Shakir, Salika M. ;
Tardif, Keith D. ;
Huang, Meei-Li ;
Jerome, Keith R. ;
Greninger, Alexander L. ;
Drobysheva, Daria ;
Spaulding, Usha ;
Rogatcheva, Margarita ;
Bourzac, Kevin M. ;
Hinrichs, S. H. ;
Broadhurst, M. J. ;
Fey, P. D. .
JOURNAL OF CLINICAL VIROLOGY, 2020, 129
[6]   Prolonged Unfrozen Storage and Repeated Freeze-Thawing of SARS-CoV-2 Patient Samples Have Minor Effects on SARS-CoV-2 Detectability by RT-PCR [J].
Dzung, Andreas ;
Cheng, Phil F. ;
Stoffel, Corinne ;
Tastanova, Aizhan ;
Turko, Patrick ;
Levesque, Mitchell P. ;
Bosshard, Philipp P. .
JOURNAL OF MOLECULAR DIAGNOSTICS, 2021, 23 (06) :691-697
[7]   In-house validation of the cobas Liat influenza A/B and RSV assay for use with gargles, sputa and endotracheal secretions [J].
Goldstein, E. J. ;
Gunson, R. N. .
JOURNAL OF HOSPITAL INFECTION, 2019, 101 (03) :289-291
[8]   Clinical Performance of the Point-of-Care cobas Liat for Detection of SARS-CoV-2 in 20 Minutes: a Multicenter Study [J].
Hansen, Glen ;
Marino, Jamie ;
Wang, Zi-Xuan ;
Beavis, Kathleen G. ;
Rodrigo, John ;
Labog, Kylie ;
Westblade, Lars F. ;
Jin, Run ;
Love, Nedra ;
Ding, Karen ;
Garg, Sachin ;
Huang, Alan ;
Sickler, Joanna ;
Tran, Nam K. .
JOURNAL OF CLINICAL MICROBIOLOGY, 2021, 59 (02)
[9]  
Hetem DJ, 2019, J CLIN MICROBIOL, V57, DOI [10.1128/JCM.00416-19, 10.1128/jcm.00416-19]
[10]  
Infectious Diseases Society of America, COVID 19 REAL TIME L