Incorporation of the electrode-electrolyte interface into finite-element models of metal microelectrodes

被引:87
作者
Cantrell, Donald R. [1 ,2 ]
Inayat, Samsoon [1 ,5 ]
Taflove, Allen [3 ]
Ruoff, Rodney S. [4 ]
Troy, John B. [1 ,2 ]
机构
[1] Northwestern Univ, Dept Biomed Engn, Evanston, IL 60208 USA
[2] Northwestern Univ, Inst Neurosci, Evanston, IL 60208 USA
[3] Northwestern Univ, Dept Elect Engn & Comp Sci, Evanston, IL 60208 USA
[4] Northwestern Univ, Dept Engn Mech, Evanston, IL 60208 USA
[5] Univ Engn & Technol, Dept Mech & Control Engn, Lahore 54890, Pakistan
关键词
D O I
10.1088/1741-2560/5/1/006
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An accurate description of the electrode-electrolyte interfacial impedance is critical to the development of computational models of neural recording and stimulation that aim to improve understanding of neuro-electric interfaces and to expedite electrode design. This work examines the effect that the electrode-electrolyte interfacial impedance has upon the solutions generated from time-harmonic finite-element models of cone- and disk-shaped platinum microelectrodes submerged in physiological saline. A thin-layer approximation is utilized to incorporate a platinum-saline interfacial impedance into the finite-element models. This approximation is easy to implement and is not computationally costly. Using an iterative nonlinear solver, solutions were obtained for systems in which the electrode was driven at ac potentials with amplitudes from 10 mV to 500 mV and frequencies from 100 Hz to 100 kHz. The results of these simulations indicate that, under certain conditions, incorporation of the interface may strongly affect the solutions obtained. This effect, however, is dependent upon the amplitude of the driving potential and, to a lesser extent, its frequency. The solutions are most strongly affected at low amplitudes where the impedance of the interface is large. Here, the current density distribution that is calculated from models incorporating the interface is much more uniform than the current density distribution generated by models that neglect the interface. At higher potential amplitudes, however, the impedance of the interface decreases, and its effect on the solutions obtained is attenuated.
引用
收藏
页码:54 / 67
页数:14
相关论文
共 57 条
  • [1] BATCH-FABRICATED THIN-FILM ELECTRODES FOR STIMULATION OF THE CENTRAL AUDITORY-SYSTEM
    ANDERSON, DJ
    NAJAFI, K
    TANGHE, SJ
    EVANS, DA
    LEVY, KL
    HETKE, JF
    XUE, XL
    ZAPPIA, JJ
    WISE, KD
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1989, 36 (07) : 693 - 704
  • [2] Current distribution at a disk electrode during a current pulse
    Antohi, P
    Scherson, DA
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2006, 153 (02) : E17 - E24
  • [3] ON THE IMPEDANCE OF THE SILICON DIOXIDE ELECTROLYTE INTERFACE
    BOUSSE, L
    BERGVELD, P
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1983, 152 (1-2): : 25 - 39
  • [4] OPERATION OF CHEMICALLY SENSITIVE FIELD-EFFECT SENSORS AS A FUNCTION OF THE INSULATOR-ELECTROLYTE INTERFACE
    BOUSSE, L
    DEROOIJ, NF
    BERGVELD, P
    [J]. IEEE TRANSACTIONS ON ELECTRON DEVICES, 1983, 30 (10) : 1263 - 1270
  • [5] AN EXPERIMENTAL STUDY OF NONUNIFORM CURRENT DISTRIBUTION AT ROTATING DISK ELECTRODES
    BRUCKENSTEIN, S
    MILLER, B
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1970, 117 (08) : 1044 - +
  • [6] Sources and effects of electrode impedance during deep brain stimulation
    Butson, CR
    Maks, CB
    McIntyre, CC
    [J]. CLINICAL NEUROPHYSIOLOGY, 2006, 117 (02) : 447 - 454
  • [7] Tissue and electrode capacitance reduce neural activation volumes during deep brain stimulation
    Butson, CR
    McIntyre, CC
    [J]. CLINICAL NEUROPHYSIOLOGY, 2005, 116 (10) : 2490 - 2500
  • [8] A novel approach to compute the impedance matrix of a cochlear implant system incorporating an electrode-tissue interface based on finite element method
    Choi, CTM
    Lai, WD
    Lee, SS
    [J]. IEEE TRANSACTIONS ON MAGNETICS, 2006, 42 (04) : 1375 - 1378
  • [9] Cochlear implantation for the treatment of deafness
    Copeland, BJ
    Pillsbury, HC
    [J]. ANNUAL REVIEW OF MEDICINE, 2004, 55 : 157 - 167
  • [10] PERFORMANCE OF PLANAR MULTISITE MICROPROBES IN RECORDING EXTRACELLULAR SINGLE-UNIT INTRACORTICAL ACTIVITY
    DRAKE, KL
    WISE, KD
    FARRAYE, J
    ANDERSON, DJ
    BEMENT, SL
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1988, 35 (09) : 719 - 732