Challenges and Strategies in Developing an Enzymatic Wearable Sweat Glucose Biosensor as a Practical Point-Of-Care Monitoring Tool for Type II Diabetes

被引:81
作者
Khor, Sook Mei [1 ,2 ]
Choi, Joonhwa [1 ]
Won, Phillip [3 ]
Ko, Seung Hwan [1 ,4 ]
机构
[1] Seoul Natl Univ, Dept Mech Engn, 1 Gwanak Ro, Seoul 08826, South Korea
[2] Univ Malaya, Dept Chem, Fac Sci, Kuala Lumpur 50603, Malaysia
[3] Carnegie Mellon Univ, Dept Mech Engn, Pittsburgh, PA 15213 USA
[4] Seoul Natl Univ, Inst Adv Machines & Design, Inst Engn Res, Seoul 08826, South Korea
基金
新加坡国家研究基金会;
关键词
flexible patch; real-time sweat monitoring; type II diabetes; enzymatic and non-enzymatic wearable glucose biosensor; INSULIN; SENSORS; DELIVERY;
D O I
10.3390/nano12020221
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Recently, several studies have been conducted on wearable biosensors. Despite being skin-adhesive and mountable diagnostic devices, flexible biosensor patches cannot truly be considered wearable biosensors if they need to be connected to external instruments/processors to provide meaningful data/readings. A realistic and usable wearable biosensor should be self-contained, with a fully integrated device framework carefully designed and configured to provide reliable and intelligent diagnostics. There are several major challenges to achieving continuous sweat monitoring in real time for the systematic and effective management of type II diabetes (e.g., prevention, screening, monitoring, and treatment) through wearable sweat glucose biosensors. Consequently, further in-depth research regarding the exact interrelationship between active or passive sweat glucose and blood glucose is required to assess the applicability of wearable glucose biosensors in functional health monitoring. This review provides some useful insights that can enable effective critical studies of these unresolved issues. In this review, we first classify wearable glucose biosensors based on their signal transduction, their respective challenges, and the advanced strategies required to overcome them. Subsequently, the challenges and limitations of enzymatic and non-enzymatic wearable glucose biosensors are discussed and compared. Ten basic criteria to be considered and fulfilled in the development of a suitable, workable, and wearable sweat-based glucose biosensor are listed, based on scientific reports from the last five years. We conclude with our outlook for the controllable, well-defined, and non-invasive monitoring of epidermal glucose for maximum diagnostic potential in the effective management of type II diabetes.
引用
收藏
页数:23
相关论文
共 63 条
[1]  
[Anonymous], 2009, Diffusion: Mass transfer in fluid systems
[2]   Fully Stretchable Capillary Microfluidics-Integrated Nanoporous Gold Electrochemical Sensor for Wearable Continuous Glucose Monitoring [J].
Bae, Chan Wool ;
Phan Tan Toi ;
Kim, Bo Yeong ;
Lee, Won Il ;
Lee, Han Byeol ;
Hanif, Adeela ;
Lee, Eung Hyuk ;
Lee, Nae-Eung .
ACS APPLIED MATERIALS & INTERFACES, 2019, 11 (16) :14567-14575
[3]   Wearable Sensors for Biochemical Sweat Analysis [J].
Bandodkar, Amay J. ;
Jeang, William J. ;
Ghaffari, Roozbeh ;
Rogers, John A. .
ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, VOL 12, 2019, 12 :1-22
[4]   Battery-free, skin-interfaced microfluidic/electronic systems for simultaneous electrochemical, colorimetric, and volumetric analysis of sweat [J].
Bandodkar, Amay J. ;
Gutruf, Philipp ;
Choi, Jungil ;
Lee, KunHyuck ;
Sekine, Yurina ;
Reeder, Jonathan T. ;
Jeang, William J. ;
Aranyosi, Alexander J. ;
Lee, Stephen P. ;
Model, Jeffrey B. ;
Ghaffari, Roozbeh ;
Su, Chun-Ju ;
Leshock, John P. ;
Ray, Tyler ;
Verrillo, Anthony ;
Thomas, Kyle ;
Krishnamurthi, Vaishnavi ;
Han, Seungyong ;
Kim, Jeonghyun ;
Krishnan, Siddharth ;
Hang, Tao ;
Rogers, John A. .
SCIENCE ADVANCES, 2019, 5 (01)
[5]   Tattoo-Based Noninvasive Glucose Monitoring: A Proof-of-Concept Study [J].
Bandodkar, Amay J. ;
Jia, Wenzhao ;
Yardimci, Ceren ;
Wang, Xuan ;
Ramirez, Julian ;
Wang, Joseph .
ANALYTICAL CHEMISTRY, 2015, 87 (01) :394-398
[6]   Wearable sweat sensors [J].
Bariya, Mallika ;
Nyein, Hnin Yin Yin ;
Javey, Ali .
NATURE ELECTRONICS, 2018, 1 (03) :160-171
[7]   Roll-to-Roll Gravure Printed Electrochemical Sensors for Wearable and Medical Devices [J].
Bariya, Mallika ;
Shahpar, Ziba ;
Park, Hyejin ;
Sun, Junfeng ;
Jung, Younsu ;
Gao, Wei ;
Nyein, Hnin Yin Yin ;
Liaw, Tiffany Sun ;
Tai, Li-Chia ;
Ngo, Quynh P. ;
Chao, Minghan ;
Zhao, Yingbo ;
Hettick, Mark ;
Cho, Gyoujin ;
Javey, Ali .
ACS NANO, 2018, 12 (07) :6978-6987
[8]   Test-Retest Reliability of Quantitative Sudomotor Axon Reflex Testing [J].
Berger, Michael J. ;
Kimpinski, Kurt .
JOURNAL OF CLINICAL NEUROPHYSIOLOGY, 2013, 30 (03) :308-312
[9]  
Ching K. W., 2016, Int. J. Netw. Secur. Its Appl., V8, P19, DOI 10.5121/ijnsa.2016.8302
[10]   Soft, Skin-Integrated Multifunctional Microfluidic Systems for Accurate Colorimetric Analysis of Sweat Biomarkers and Temperature [J].
Choi, Jungil ;
Bandodkar, Amay J. ;
Reeder, Jonathan T. ;
Ray, Tyler R. ;
Turnquist, Amelia ;
Kim, Sung Bong ;
Nyberg, Nathaniel ;
Hourlier-Fargette, Aurelie ;
Model, Jeffrey B. ;
Aranyosi, Alexander J. ;
Xu, Shuai ;
Ghaffari, Roozbeh ;
Rogers, John A. .
ACS SENSORS, 2019, 4 (02) :379-388