Differential pulse anodic stripping voltammetric determination of Cd and Pb at a bismuth glassy carbon electrode modified with Nafion, poly(2,5-dimercapto-1,3,4-thiadiazole) and multiwalled carbon nanotubes

被引:48
作者
He, Xiuhui [1 ]
Su, Zhaohong [1 ]
Xie, Qingji [1 ]
Chen, Chao [1 ]
Fu, Yingchun [1 ]
Chen, Li [1 ]
Liu, Ying [1 ]
Ma, Ming [1 ]
Deng, Le [1 ]
Qin, Dilan [2 ]
Luo, Yueping [2 ]
Yao, Shouzhuo [1 ]
机构
[1] Hunan Normal Univ, Coll Chem & Chem Engn, Minist Educ China, Key Lab Chem Biol & Tradit Chinese Med Res, Changsha 410081, Hunan, Peoples R China
[2] Environm Monitoring Ctr Hunan Prov, Changsha 410004, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
Differential pulse anodic stripping voltammetry; Simultaneous determination of Cd(2+) and Pb(2+); Poly(2,5-dimercapto-1,3,4-thiadiazole); Multiwalled carbon nanotubes; Bismuth film electrode; MERCURY FILM ELECTRODES; HEAVY-METAL IONS; TRACE-METALS; ELECTROCHEMICAL POLYMERIZATION; SENSITIVE DETERMINATION; COMPOSITE ELECTRODES; AQUEOUS-SOLUTION; LEAD; CADMIUM; ADSORPTION;
D O I
10.1007/s00604-010-0541-8
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Differential pulse anodic stripping voltammetry was applied to detect Pb(2+) and Cd(2+) at a glassy carbon electrode modified with Nafion, poly(2,5-dimercapto-1,3,4-thiadiazole) (PDMcT), and multiwalled carbon nanotubes (MWCNTs). Preconcentration was accomplished at -1.0 V vs. SCE in pH 5 buffer containing 400 mu g L(-1) Bi(3+) for 6 min and resulted in high sensitivity, selectivity and reproducibility. Electrochemical quartz crystal microbalance studies revealed that PDMcT is cleaved under the reductive conditions to form thiol groups that bind Pb(2+) and Cd(2+) ions, whilst the Nafion binder stabilizes the film and the MWCNTs improve electroactivity. The presence of the bismuth film improves sensitivity and reproducibility. Under optimum conditions, the electrode responds linearly to Cd(2+) ions in the concentration range from 0.05 to 20 mu g L(-1), and to Pb(2+) from 0.1 to 22 mu g L(-1). The limits of detection (S/N= 3) are 0.03 and 0.05 mu g L(-1), respectively. This method was successfully applied to the determination of the two ions in water samples.
引用
收藏
页码:95 / 102
页数:8
相关论文
共 47 条
[1]   Arsenic speciation and reactivity in poultry litter [J].
Arai, Y ;
Lanzirotti, A ;
Sutton, S ;
Davis, JA ;
Sparks, DL .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2003, 37 (18) :4083-4090
[2]  
BURLINGAME AL, 1996, ANAL CHEM, V68, P599
[3]   Sensitive determination of Cd and Pb by differential pulse stripping voltammetry with in situ bismuth-modified zeolite doped carbon paste electrodes [J].
Cao, Linyuan ;
Jia, Jianbo ;
Wang, Zhenhui .
ELECTROCHIMICA ACTA, 2008, 53 (05) :2177-2182
[4]   Application of graphite-epoxy composite electrodes in differential pulse anodic stripping voltammetry of heavy metals [J].
Carrégalo, S ;
Merkoçi, A ;
Alegret, S .
MICROCHIMICA ACTA, 2004, 147 (04) :245-251
[5]   Thiol-Functionalized Silica Thin Film Modified Electrode in Determination of Mercury Ions in Natural Water [J].
Cesarino, Ivana ;
Gomes Cavalheiro, Eder Tadeu .
ELECTROANALYSIS, 2008, 20 (21) :2301-2309
[6]   Voltammetric detection of cadmium ions at glutathione-modified gold electrodes [J].
Chow, E ;
Hibbert, DB ;
Gooding, JJ .
ANALYST, 2005, 130 (06) :831-837
[7]   COMPARATIVE-STUDY OF POLYMER-COATED MERCURY FILM ELECTRODES FOR VOLTAMMETRIC ANALYSIS OF LEAD AND CADMIUM IN THE PRESENCE OF SURFACTANTS [J].
DAM, MER ;
THOMSEN, KN ;
PICKUP, PG ;
SCHRODER, KH .
ELECTROANALYSIS, 1995, 7 (01) :70-78
[8]   Mercury film electrodes coated with negatively charged polymer films in speciation studies of trace amounts of lead [J].
Dam, MER ;
Schroder, KH .
ELECTROANALYSIS, 1996, 8 (11) :1040-1050
[9]   ABTS-Multiwalled Carbon Nanotubes Nanocomposite/Bi Film Electrode for Sensitive Determination of Cd and Pb by Differential Pulse Stripping Voltammetry [J].
Deng, Wenfang ;
Tan, Yueming ;
Fang, Zhengfa ;
Xie, Qingji ;
Li, Yunyong ;
Liang, Xiaoling ;
Yao, Shouzhuo .
ELECTROANALYSIS, 2009, 21 (22) :2477-2485
[10]   Mercury film electrodes: developments, trends and potentialities for electroanalysis [J].
Economou, A ;
Fielden, PR .
ANALYST, 2003, 128 (03) :205-212